Calibrated Non Display Data Logger

Scientific Data Logger

Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard

Temprecord
Case Range

-50 °C to +60 °C
( -58 °F to +140 °F )

Temprecord
Accuracy

Calibrated Range
± 0.2°C ( 0.35°F )

Temprecord
Probe Range

-80 °C to +110 °C
( -112 °F to +230 °F )

Temprecord
Memory

32k / 32000 samples

Temprecord
Warranty

24 months

Battery: 24 months

Temprecord
Waterproof

IP67 or NEMA 6

Data resolution 0.01 °C / 0.01 °F
LED Indicate if within/outside set limits

Button Start/Stop/Mark

Free software automatically calculates:
MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)

Traceable Calibration Certificate included

Low Temp Data Logger

Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard

Temprecord
Case Range

-50°C to +60°C
( -58 °F to +140 °F )

Temprecord
Accuracy

Calibrated Range
± 0.2°C ( 0.35°F )

Temprecord
Probe Range

-50 °C to +110 °C
( -58°F to +230°F )

Temprecord
Memory

8k / 7935 samples

Temprecord
Warranty

12 months

Battery: 24 months

Temprecord
Waterproof

IP67 or NEMA 6

Data resolution 0.01 °C / 0.01 °F
LED Indicate if within/outside set limits

Button Start/Stop/Mark

Free software automatically calculates:

MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)
 
Traceable Calibration Certificate included

Supercool Data Logger

Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard

Temprecord
Case Range

-50°C to +60°C
( -58 °F to +140 °F )

Temprecord
Accuracy

Calibrated Range : ± 0.2°C ( 0.35°F )​

Temprecord
Probe Range

-80 °C to +110 °C
( -112 °F to +230 °F )

Temprecord
Memory

8k / 7935 samples

Temprecord
Warranty

12 months

Battery: 24 months

Temprecord
Waterproof

IP67 or NEMA 6

Data resolution 0.01 °C / 0.01 °F
LED Indicate if within/outside set limits
Button Start/Stop/Mark
 
Free software automatically calculates:
MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)
 
Traceable Calibration Certificate included

Medical Data Logger

Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard

Temprecord
Case Range

-50 °C to +60 °C
( -58 °F to + 140 °F )

Temprecord
Accuracy

Calibrated Range :
± 0.2°C ( 0.35°F )

Temprecord
Memory

32k / 32511 samples

Temprecord
Warranty

12 months

Battery: 24 months

Temprecord
Waterproof

IP67 or NEMA 6

Data resolution 0.01 °C / 0.01 °F
LED Indicate if within/outside set limits
Button Start/Stop/Mark
 
Free software automatically calculates:
MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)
 
Traceable Calibration Certificate included

RH Data Logger

Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard

Temprecord
Case Range

-25 °C to +60 °C
( -13 °F to + 140 °F )
0 %RH to 100 %RH

Temprecord
Accuracy

Calibrated Range :
± 0.2°C ( 0.35°F )
Humidity Range : ± 3%

Temprecord
Memory

32k / 32511 samples

Temprecord
Warranty

12 months

Battery: 24 months

Temprecord
Waterproof

IP67 or NEMA 6

Data resolution 0.01 °C / 0.01 °F
LED Indicate if within/outside set limits

Button Start/Stop/Mark

Free software automatically calculates:

MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)
 
Certificate included
 

Econolog Data Logger

Temprecord
Case Range

-25 °C to +60 °C
( -13 °F to + 140 °F )

Temprecord
Accuracy

Case Range : 0.5 °C (1 °F )

Temprecord
Memory

8k / 7985 samples

Temprecord
Waterproof

IP67 or NEMA 6

Temprecord
Warranty

12 months

Data resolution  0.01 °C / 0.01 °F
LED Indicate if within/outside set limits
Button Start/Stop/Mark
 
Free software automatically calculates:
MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)
 
Statement of Accuracy Certificate Available on Request

Multitrip Data Logger

Calibrated and corrected at 3-Points to ISO/IEC 17025 Calibration Laboratory Standard

Temprecord
Case Range

-25 °C to +60 °C
( -13 °F to +140 °F )

Temprecord
Accuracy

Calibrated Range
± 0.2°C ( 0.35°F )

Temprecord
Probe Range

-50 °C to +110 °C
( -58 °F to +230 °F )

Temprecord
Memory

8k / 7935 samples

Temprecord
Warranty

12 months

Battery: 24 months

Temprecord
Waterproof

IP67 or NEMA 6

Data resolution 0.01 °C / 0.01 °F
LED Indicate if within/outside set limits
Button Start/Stop/Mark
 
Free software automatically calculates:
MKT / Rate of Cooling / PHI & RI statistics (Potential growth of E-Coli)
 
Traceable Calibration Certificate included
Follow by Email
LinkedIn
LinkedIn
Share