The standalone, fully automatic AirSTAR CFPP is our brand new instrument for Cold Filter Plugging Point testing.
What is CFPP? … CFPP, or Cold Filter Plugging Point, is the (low) temperature at which a diesel/heating fuel will not pass through a standardized filter anymore, measured under cooling, vacuum & time conditions as described in the methods ASTM D6371, EN116, EN16329, IP309 and JIS K2288.
While fully compliant with conventional CFPP methods and equipped with all control options that are also present in similar instruments, AirSTAR CFPP offers today’s latest and most innovative technology such as NANOtech insulation, microprocessor controlled vacuum pump, solid state liquid-free cooling engine, wireless power and wireless control.
With integrated, solid state cooling down to -105ºC/-157ºF, a bench space of only 15cm/5,9″ (the width of the integrated iPad Mini), the innovative & easy hand-held CFPP module and a no-cables-no-hoses configuration, AirSTAR CFPP offers customers an instrument that is powerful, easy to use, flexible and future-proof. And, of course, with highly accurate and comparable test results.
Operation is easy and fast with the wireless hand-held CFPP module, in which all necessary components for the CFPP test are encaged. The intuitive software on the iPad Mini ensures a short learning curve for operators, so they’re able to create and customize programs and settings quickly. Multiple users and user acces levels can be created by the administrator.
Automatic cleaning is done when the CFPP pod is placed in either the ColdBlock cooling bath or the external cleaning station.
The iPad Mini can control up to 8 CFPP pods simultaneously, which gives customers the flexibility to make any combination of multiple ColdBlock cooling baths, multiple cleaning stations and CFPP pods. With this modular approach a customer’s investment in AirSTAR is always future proof.
Modern, versatile data handling option such as; send to LIMS / Windows PC, make PDF, send email, multiple printing options and more, enable AirSTAR CFPP to fit in flexibly in any existent data workflow.
• AirSTAR ColdBlock cooling unit + iPad mini
• AirSTAR CFPP Head
• AirSTAR WiPower – Cleaning-Docking station
• Spacer cage ASTM D6371
• Integrated microprocessor-controlled vacuum pump for
constant -2.0 kPa pressure according to method specifications
• Accurate sample detection with laser technology, even
when condensation and frost forming occurs
• Powercast® technology for wireless power to CFPP Head
• Pipette & filter unit, according to method specifications
• PT-100 easy click-connect, built in storage for calibration
data & unique ID
• Easy assembling
The AirSTAR CFPP software application is designed for easy & flexible control. It offers extensive options for data recording and display, and many options to customize programs. Test results and progress animation are displayed real-time.
• Create linear and stepped cooling profiles
• Create and change vacuum profiles
• Specify end-test conditions in program
• Monitor and record sample cooling rate
• Quick report of anomalous aspiration behavior
• Pre-programmed and customizable cleaning cycles
• Multiple users with variable access rights can be created by the administrator
• Connect multiple CFPP Heads to one Coldblock
• Extensive storage capacity for results, programs, settings, user information and more (16Gb iPad)
• Connect with PC (Windows operated systems) for exchanging results and settings via FTP
• Data handling options such as: send results to LIMS, make and email PDF
• Printing options such as: print PDF via AirPrint and Direct Printing on connected Kiosk printer
• Extensive options to calibrate bath jacket, vacuum pump, PT-100 probe and electronics
The AirSTAR CFPP Automator is unique in the market, and a great way for customers to upgrade their existing manual cooling bath to a powerful CFPP tester.
The AirSTAR CFPP Automator is is a fully automatic instrument for Cold Filter Plugging Point testing, only without the ColdBlock cooling unit you’ll find in the AirSTAR CFPP Analyzer.
Operation is easy and fast with the wireless hand-held CFPP Head, in which all necessary components for the CFPP test are encaged. The intuitive software on the iPad Mini ensures a short learning curve for operators, so they’re able to create and customize programs quickly. Multiple users and user access levels can be created by the administrator.
One iPad Mini can control up to 8 CFPP Head simultaneously, which enables customers to run multiple CFPP tests on one cooling bath, depending on the capacity of their bath. Automatic cleaning is done when the CFPP Head is placed in the cleaning station.
Due to the modular approach, a customer’s investment in AirSTAR is always future proof: any combination of multiple ColdBlock cooling baths, CFPP Heads and cleaning stations is possible at any time in any order.
Modern, versatile data handling option such as; send to LIMS / Windows PC, make PDF, send email, multiple printing options and more, enable AirSTAR CFPP to fit in flexibly in any existent data workflow.
• AirSTAR CFPP Head
• AirSTAR Cleaning-Docking station
• Apple iPad mini
• Apple iPad mini docking station
• No cooling unit included!