For use with:
| Meter | Description |
| #850034K | AquaShock® Water Purity Kit |
| Probe Dimensions | Handle Length: 1.25″ (32 mm) |
| Probe Length: 4.75″ (121 mm) | |
| Probe Diameter: 11 mm | |
| Cord Length: 55″ |
For use with the following:
| Meter | Description |
| 850064K | AquaShock® pH/ORP Kit |
| Probe Dimensions | Handle Length: 1.25″ (32 mm) |
| Probe Length: 4.75″ (121 mm) | |
| Probe Diameter: 11 mm | |
| Cord Length: 56″ |
This probe comes with our patented BNC connectors that are waterproof when connected to AquaShock® meters. EPA compliant refillable ATC glass pH electrode as an accessory.
For use with:
| Meter | Description |
| 850064K | AquaShock® pH/ORP Kit |
For use with the following:
| Meter | Description |
| 850081 | Water Quality Meter |
| 850086 | Water Quality Meter Kit |
| Unit of Measure: | Range: | Resolution: | Accuracy: |
|---|---|---|---|
| μS: | 0 to 200 | 0.1 | ±(2% fs+1 d) |
| mS: | 0.2 to 2.000 | 0.001 | |
| 2 to 20 | 0.01 | ||
| 20 to 200 | 0.1 | ||
| ppm: | 0 to 132 | 0.1 | |
| 132 to 1,320 | 1 | ||
| 1,320 to 13,200 | 10 | ||
| 13,200 to 132,000 | 100 | ||
| % Salinity: | 0 to 12% | 0.01% | 0.5% |
For use with the following meters:
| Meter | Description |
| 850081 | Water Quality Meter |
| 850086 | Water Quality Meter Kit |
| Unit of Measurement: | Range: | Resolution: | Accuracy: |
| DO: | 0 to 20 mg/L | 0.1 | ±0.4 |
| O2 in Air: | 0 to 100.0% | ±0.7 | |
| Temperature °F: | 32°F to 132°F | 0.1° | ±1.5 |
| Temperature °C: | 0°C to 50°C | ±0.8 |
For use with the following:
| Meter | Description |
| 850081 | Water Quality Meter |
| 850086 | Water Quality Meter Kit |
| Unit of Measure: | Range: | Resolution: | Accuracy: |
| Temperature ° F: | 32°F to 140°F | 0.1 | ±1.5 |
| Temperature ° C: | 0°C to 60°C | ±0.8 |
| Probe Dimensions: | Probe Handle: 2″ (51 mm) |
| Probe Length: 4.25 (108 mm) | |
| Probe Diameter: 3 mm | |
| Cord Length: 43″ |
For use with the following meters (for use with PH):
850081 Water Quality Meter
| Unit of Measurement | Range | Resolution | Accuracy |
| °C | 0 to 65 | 0.1 | ±0.8 pH |
| °F | 32 to 149 | ±1.5 pH |
For use with the following meters:
| Meter | Description |
| 850038 | Conductivity, TDS, Salinity Meter |
| 860031 | Benchtop pH / mV Meter |
| 860032 | Benchtop Conductivity/TDS/Salinity Meter |
| 860033 | Benchtop Water Quality Meter |
| Unit of Meassure: | Range: | Resolution: | Accuracy: |
| Conductivity μS/cm: | 0 to 19.9 0 to 199.9 0 to 1999 | 0.01 0.1 1 | ±1% fs + 1d
|
| Conductivity mS/cm: | 0 to 19.99 0 to 199.9 | 0.01 0.1 |
Flat Surface pH probe is useful for reading the pH of small amounts of liquid, food products, and other surface pH measurements. The probe comes with a 40” cable and works with all Sper Scientific pH Meters, as well as any others, with a standard BNC connector.
The probe measures the pH of a solution. This probe has a flat surface and is commonly used in testing surface measurements such as cheese, meats, small liquid samples, paper, soil, or skin. It features a single-junction electrode for general-purpose applications. The junction is sealed for low maintenance use and is easy to clean.
The primary difference between Type J and Type K thermocouples is the measuring range, and the sensitivity. Type K is the most common general purpose thermocouple with a sensitivity of approximately 41 µV/°C. A wide variety of probes are available in its −50°C to +900°C / -58°F to +1652°F range. Type K wire color standard is yellow (+) and red (-). Type J has a more restricted range of −50 to +400°C, but higher sensitivity of about 50 µV/°C. Type J wire color standard is white (+) and red (-).
| Immersion & General Purpose | |||
| Probe Type | Application | Measurment Range | Accuracy |
| K | High Temperature | -50 to 900ºC -58 to 1652ºF | -40 to 375°C, ± 1.5°C 376 to 1050°C, ±0.4% |
| Dimensions | Handle Length: 4″ (105 mm) Probe Length: 3.3″ (83 mm) Probe Diam: 8 mm Cord Length: 46″ | ||
For use with the following Sper Meters:
| Meter | Description |
| 850055 | Advanced pH Meter |
| 850060 | pH SD Card Logger Meter |
| 850081 | Water Quality Meter |
| 860031 | Benchtop pH / mV Meter |
| 860033 | Benchtop Water Quality Meter |
| Unit of Measure: | Range: | Resolution: | Accuracy: |
| mV | -1999 to 1999 | 1 | ±(0.5%+2d) |
| Operation Temperature: | 0 to 60°C /32 to 140°F |
| Probe Dimensions: | Probe Length: 4.5″ (114 mm) |
| Probe Diameter: 12 mm | |
| Cord Length: 37.4″ | |
| Plug: | BNC Connector |
| Body Material: | Epoxy |
| Response Time: | seconds |
For use with the following meters (BNC connector):
| Meter | Description |
| 840087 | Basic pH Meter |
| 850055 | Advanced pH Meter |
| 850060 | pH SD Card Logger |
| 850081 | Water Quality Meter |
| 860031 | Benchtop pH/mV Meter |
| 860033 | Benchtop Water Quality Meter |
| Unit of Measure: | Range: | Resolution: | Accuracy: |
| pH | 0 to 14 pH | 0.01 pH | ±(0.02pH+2d) |
| Operation Temperature: | 0 to 60°C /32 to 140°F |
| Probe Dimensions: | Probe Length: 5.5″ (140 mm) |
| Probe Diameter: 12 mm | |
| Cord Length: 48″ | |
| Plug: | BNC Connector |
| Body Material: | PP |
| Response Time: | seconds |
Replacement ATC (Automatic Temperature Compensation) pH Probe.
For use with the following:
| Meter | Description |
| 850055/56 | Advanced pH Meter & Kit |
| 860031 | Benchtop pH/mV Meter |
| 860033 | Benchtop Water Quality Meter |
| Unit of Measure: | Range: | Resolution: | Accuracy: |
| pH | 0 to 14 pH | 0.01 pH | ±(0.02pH+2d) |
| Operation Temperature: | 0 to 60°C /32 to 140°F |
| Probe Dimensions: | Probe Length: 5.5″ (140 mm) |
| Probe Diameter: 12 mm | |
| Cord Length: 49″ | |
| Plug: | BNC Connector |
| Body Material: | PP |
| Response Time: | seconds |
Pt 1000 Temperature Probe for use with Mini Environmental Meter #850027.Sper Scientific platinum resistance thermometer (PT1000) offers excellent accuracy over a wide temperature range (14.0 to 158.0 °F | -10.0 to 70.0°C). Pt 1000 thermometers are also referred to as RTD thermometers.
For use with Mini Environmental Meter #850027 only.
| Range | Resolution | Accuracy |
| -14.0 to 158.0°F / -10.0 to 70.0°C | 0.1°F / °C | ±2.5°F / ±1.2°C |
| Probe Dimensions | Probe Handle: 2″ (51 mm) |
| Probe Length: 4.25 (108 mm) | |
| Probe Diameter: 4 mm | |
| Cord Length: 40″ |
For use with the following meters:
| Meter | Description |
| 850045 | Dissolved Oxygen Pen |
| 850081/86 | Water Quality Meter & Kit |
| Item | Unit of Measurement | Range | Resolution | Accuracy |
| pH Probe 840016 (BNC connector) | pH | 0 to 14 | 0.01 | ±(0.02pH+2d) |
| Spear Tip pH Probe 840049 (for non-liquid measurement, BNC connector) | pH | 0 to 14 | 0.01 | ±(0.02pH+2d) |
| ATC Temp. Probe 850082 (for use with PH) | Temperature °C | 0 to 65 | 0.1 | ±0.8 |
| Temperature °F | 32 to 149 | ±1.5 | ||
| Conductivity Probe 850083 | mS | 0.2 to 1.999 | 0.001 | ±(3%fs+1d) |
| mS | 2 to 19.99 | 0.01 | ||
| Temperature ºC | 0 to 60 | 0.1 | 0.8 | |
| Temperature ºF | 32 to 140 | 1.5 | ||
| Conductivity/TDS Probe 850084 | mS | 0.2 to 2.000 | 0.001 | ±(3%fs+1d) |
| mS | 2 to 20.00 | 0.01 | ||
| PPM | 132 to 1320 | 1 | ||
| PPM | 1320 to 13,200 | 10 | ||
| Temperature ºC | 0 to 60 | 0.1 | 0.8 | |
| Temperature ºF | 32 to 140 | 1.5 | ||
| DO Probe 850087 (4 m cable) | mg/L | 0 to 20 | 0.1 | ±0.4 |
| Temperature °C | 0 to 50 | 0.8 | ||
| Temperature °F | 32 to 122 | 1.5 | ||
| Head w/Diaphragm 850089 | Accessory for DO Probe 850087 | |||
| ORP Probe 850088 | mV | 0 to 1999 | 1 | ±(0.5%+2d) |
Food service replacement probe.
| Measuring Range | Resolution | Accuracy |
| -50 to 400°C -58 to 752°F | 0.1°C / °F | ±(0.15 + (0.002 x T))°C T = Measuring Temperature. For example: Accuracy is 0.15°C for 0°C reading. Accuracy is 0.35°C for 100°C reading. Accuracy is 0.95°C for 400°C reading. |
| Probe Dimensions | Sensing Head: 6″ (155 mm tube) |
| Probe Handel Length: 5″ (130 mm) | |
| Probe Diameter: 3.2 mm | |
| Cord Length: 39″ | |
| Features | Cooperate with an 0.00385 alpha coefficient, meet DIN IEC 751 |
| 0°C resistance | 100 ohm |
| Plug | DIN plug, 4 pin/4wires |
| Class | Class A |
Spear Tip pH Probe (for non-liquid measurement, BNC connector) is perfect for those pH measurements in the applications where sample piercing is required.
Meat, sausage and cheese are ideal applications. the electrode features a very durable glass measuring spear packaged in a rugged virtually unbreakable epoxy body.
Works with the following meters:
| Meter | Description |
|---|---|
| 840087 | Basic pH Meter |
| 850055 | Advanced pH Meter |
| 850060 | pH SD Card Logger |
| 850081 | Water Quality Meter |
| 860031 | Benchtop pH/mV Meter |
| 860033 | Benchtop Water Quality Meter |
pH 1 to 13 0.01 ±(0.02 pH + 2d)
| Range: | Resolution: | Accuracy: | |
|---|---|---|---|
| pH | 1 to 13 | 0.01 | ±(0.02 pH + 2d) |
| Operating Temperature: | 5 to 60°C 41 to 140°F | ||
| Electrode Structure: | Combination type | ||
| Reference of pH Electrode: | Ag/AgCl, Double Junction | ||
| Response Time: | ≤ 2 minutes | ||
| pH value of zero mV: | 7 ± 1 pH | ||
| Repeatability: | ≥ 0.05 pH | ||
| Mechanical Protection: | With protection bottle on the electrode head. | ||
| Weight: | 68 g (including cable and socket) | ||
| Dimensions: | Probe Length: 6″ (150 mm) | ||
| Probe Diameter: 12 mm | |||
| Cable Length: 29.5″ | |||
The primary difference between Type J and Type K thermocouples is the measuring range, and the sensitivity. Type K is the most common general purpose thermocouple with a sensitivity of approximately 41 µV/°C. A wide variety of probes are available in its −50°C to +900°C / -58°F to +1652°F range. Type K wire color standard is yellow (+) and red (-). Type J has a more restricted range of −50 to +400°C, but higher sensitivity of about 50 µV/°C. Type J wire color standard is white (+) and red (-).
| Ambient | |||
| Type | Application | Temperature Range | Dimensions |
| J | Beaded wire for fast response in air and gas in difficult to access areas | -50 to 200ºC -58 to 392ºF | Cord Length: 36″ |
The primary difference between Type J and Type K thermocouples is the measuring range, and the sensitivity. Type K is the most common general-purpose thermocouple with a sensitivity of approximately 41 µV/°C.
A wide variety of probes are available in its −50°C to +900°C/ -58°F to +1652°F range. Type K wire color standard is yellow (+) and red (-). Type J has a more restricted range of −50 to +400°C, but higher sensitivity of about 50 µV/°C. Type J wire color standard is white (+) and red (-).
| Immersion & General Purpose Thermometer Probe | |||
|---|---|---|---|
| Type | Application | Temperature Range | Dimensions |
| J | Small | -50 to 300ºC -58 to 572ºF | Handle Length: 4.5″ (114 mm) Probe Length: 4″ (102 mm) Probe Diam: 2 mm Cord Length: 40″ |
The primary difference between Type J and Type K thermocouples is the measuring range, and the sensitivity. Type K is the most common general purpose thermocouple with a sensitivity of approximately 41 µV/°C.
A wide variety of probes are available in its −50°C to +900°C / -58°F to +1652°F range. Type K wire color standard is yellow (+) and red (-). Type J has a more restricted range of −50 to +400°C, but higher sensitivity of about 50 µV/°C. Type J wire color standard is white (+) and red (-).
| Ambient Thermometer Probe | |||
|---|---|---|---|
| Type | Application | Temperature Range | Dimensions |
| K | Fast response in air & gas. Sheath protected element | -50 to 600ºC -58 to 1112ºF | Handle Length: 4.5″ (114 mm) Probe Length: 8″ (203 mm) Probe Diam: 11 mm Max Cord Length: 40″ |
The primary difference between Type J and Type K thermocouples is the measuring range, and the sensitivity. Type K is the most common general-purpose thermocouple with a sensitivity of approximately 41 µV/°C. A wide variety of probes are available in its −50°C to +900°C / -58°F to +1652°F range. Type K wire color standard is yellow (+) and red (-). Type J has a more restricted range of −50 to +400°C, but higher sensitivity of about 50 µV/°C. Type J wire color standard is white (+) and red (-).
| Ambient | |||
| Type | Application | Temperature Range | Accuracy |
| K | Beaded wire for fast response in air and gas in difficult to access areas | -50 to 300ºC -58 to 572ºF Max. short-term operating temperature: 250°C (482°F) | ± 0.4% |
| It is an ultra fast response naked-bead thermocouple suitable for many general purpose applications. | |||
| Dimensions | Cord Length: 47″ | ||
The primary difference between Type J and Type K thermocouples is the measuring range, and the sensitivity. Type K is the most common general-purpose thermocouple with a sensitivity of approximately 41 µV/°C. A wide variety of probes are available in its −50°C to +900°C / -58°F to +1652°F range. Type K wire color standard is yellow (+) and red (-). Type J has a more restricted range of −50 to +400°C, but higher sensitivity of about 50 µV/°C. Type J wire color standard is white (+) and red (-).
| Immersion & General Purpose | |||
| Type | Application | Measurement Range | Accuracy |
| K | Large | -50 to 400ºC -58 to 752ºF | ± 0.75% |
| Dimensions | Handle Length: 5.2″ (133 mm) Probe Length: 6″ (152 mm) Probe Diam: 3 mm Cord Length: 40″ | ||
| Immersion & General Purpose | |||
| Type | Application | Temperature Range | Dimensions |
| K | Small | -50 to 300ºC -58 to 572ºF | Handle Length: 4.5″ (114 mm) Probe Length: 4″ (102 mm) Probe Diam: 2 mm Cord Length: 40″ |
The primary difference between Type J and Type K thermocouples is the measuring range, and the sensitivity. Type K is the most common general-purpose thermocouple with a sensitivity of approximately 41 µV/°C.
A wide variety of probes are available in its −50°C to +900°C / -58°F to +1652°F range. Type K wire color standard is yellow (+) and red (-). Type J has a more restricted range of −50 to +400°C, but higher sensitivity of about 50 µV/°C. Type J wire color standard is white (+) and red (-).
| Surface Probe | |||
|---|---|---|---|
| Type | Application | Temperature Range | Dimensions |
| K | Magnetic, for use on stationary metal surfaces | -50 to 250ºC -58 to 482ºF | Probe Length: 1.7″ (44 mm) Probe Width: 10 mm Max Cord Length: 45″ |
The primary difference between Type J and Type K thermocouples is the measuring range, and the sensitivity. Type K is the most common general-purpose thermocouple with a sensitivity of approximately 41 µV/°C. A wide variety of probes are available in its −50°C to +900°C / -58°F to +1652°F range. Type K wire color standard is yellow (+) and red (-). Type J has a more restricted range of −50 to +400°C, but higher sensitivity of about 50 µV/°C. Type J wire color standard is white (+) and red (-).
| Penetration | |||
| Type | Application | Temperature Range | Dimensions |
| K | Insertion | -50 to 400ºC -58 to 752ºF | Handle Length: 4.5″ Probe Length: 4″ Probe Diam: 3 mm Max Cord Length: 53″ |
The primary difference between Type J and Type K thermocouples is the measuring range, and the sensitivity. Type K is the most common general-purpose thermocouple with a sensitivity of approximately 41 µV/°C.
A wide variety of probes are available in its −50°C to +900°C / -58°F to +1652°F range. Type K wire color standard is yellow (+) and red (-). Type J has a more restricted range of −50 to +400°C, but higher sensitivity of about 50 µV/°C. Type J wire color standard is white (+) and red (-).
| Penetration Probe | |||
|---|---|---|---|
| Type | Application | Temperature Range | Dimensions |
| K | Large | -50 to 400ºC -58 to 752ºF | Handle Length: 4.5″ Probe Length: 6″ Probe Diam: 3 mm Max Cord Length: 53″ |
The primary difference between Type J and Type K thermocouples is the measuring range, and the sensitivity. Type K is the most common general-purpose thermocouple with a sensitivity of approximately 41 µV/°C.
A wide variety of probes are available in its −50°C to +900°C / -58°F to +1652°F range. Type K wire color standard is yellow (+) and red (-). Type J has a more restricted range of −50 to +400°C, but higher sensitivity of about 50 µV/°C. Type J wire color standard is white (+) and red (-).
| Penetration Thermometer Probe | |||
|---|---|---|---|
| Type | Application | Temperature Range | Dimensions |
| K | Small | -30 to 480ºC -22 to 896ºF | Handle Length: 4.5″ Probe Length: 3.25″ Probe Diam: 2 mm Cord Length: 44″ |
The primary difference between Type J and Type K thermocouples is the measuring range, and the sensitivity. Type K is the most common general-purpose thermocouple with a sensitivity of approximately 41 µV/°C.
A wide variety of probes are available in its −50°C to +900°C / -58°F to +1652°F range. Type K wire color standard is yellow (+) and red (-). Type J has a more restricted range of −50 to +400°C, but higher sensitivity of about 50 µV/°C. Type J wire color standard is white (+) and red (-).
| Surface Thermometer Probe | |||
|---|---|---|---|
| Type | Application | Temperature Range | Dimensions |
| K | Standard | -50 to 400ºC -58 to 752ºF | Handle Length: 4″ (102 mm) Probe Length: 8″ (203 mm) Probe Diam: 13 mm Max Cord Length: 45″ |
The primary difference between Type J and Type K thermocouples is the measuring range, and the sensitivity. Type K is the most common general-purpose thermocouple with a sensitivity of approximately 41 µV/°C.
A wide variety of probes are available in its −50°C to +900°C / -58°F to +1652°F range. Type K wire color standard is yellow (+) and red (-). Type J has a more restricted range of −50 to +400°C, but higher sensitivity of about 50 µV/°C. Type J wire color standard is white (+) and red (-).
| Surface Thermometer Probe | |||
|---|---|---|---|
| Type | Application | Temperature Range | Dimensions |
| K | Hard to access areas | -30 to 480ºC -22 to 896ºF | Handle Length: 5.5″ (140 mm) Probe Length: 8″ (203 mm) Probe Diam:13 mm Cord Length: 38″ |