Poor air quality may cause tiredness, inability to concentrate, and even illness (i.e., Sick Building Syndrome). Ideal for monitoring indoor air quality in homes, offices classrooms, hotels or anywhere air quality is important. Fresh air is especially important to help lessen the spread of contagions and maintain a healthy environment.
Provides audible alarms for CO2 threshold. Maintenance free sensor ensures long-term accuracy, stability and reliability. The compact design features a large display with a bar graph indicating CO2 trend for up to 24 hours. 3 backlight colors indicate air quality status with four additional user selectable backlight color choices. Calibrates easily to fresh air and comes with a USB power cable. Will stand on a desktop or can be wall mounted.
Dimensions: 4½” × 2 ½” × 1 ¼” (108 × 67 × 30 mm)
Weight: 3 oz (90 g)
Range | Resolution | Accuracy | |
Temperature | 0.0 º – 50º C (32 º – 122º F) | 0.1ºC/ºF | +/- 0.6 º C / 0.9º F |
RH | 5-9% RH | 1% RH | +/- 5%RH (@25º C, 10-90% RH) +/- 7%RH (@25º C, Other Range) |
CO2 | 200-5000 PPM | 1 PPM | +/- 50 PPM +/- 5% of reading (200-3000 PPM) Other range is 10% of reading |
Large display continually monitors the primary IAQ (Indoor Air Quality) parameters:
Poor air quality may cause tiredness, inability to concentrate, and even illness (i.e., Sick Building Syndrome). This instrument is ideal for monitoring indoor air quality in crowded public spaces with potentially high levels of CO2 (carbon dioxide) such as offices, factories, classrooms, hospitals and hotels. Recalls min/max CO2 levels and provides visual alarms for maximum CO2 threshold. Automatic Baseline Calibration (ABC) and maintenance free NDIR (non-dispersive infrared) CO2 sensor ensure long-term accuracy, stability and reliability. Comes with an AC adapter (800059) and will stand on a desk-top or wall mount.
Dimensions: 4½” × 4¼” × 1″ (108 × 115 × 25 mm)
Weight: 6 oz (170 g)
Range | Resolution | Accuracy | |
---|---|---|---|
Temperature | -10 to 50°C -14 to 122°F | 0.1°C & F | ±0.6°C (-10 to 50°C) otherwise ±1.2°C, ±2.5°F |
RH | 10% to 90% | 0.1% | ±5% (@25°C & 10 to 99% RH) otherwise ±7% |
CO2 | 0 to 9999 ppm | 1 ppm | ±75 ppm +5% of rdg (0 to 2000 ppm) |
Poor air quality may cause tiredness, inability to concentrate, and even illness (i.e., Sick Building Syndrome). This instrument is ideal for monitoring indoor air quality in crowded public spaces with potentially high levels of CO2 (carbon dioxide) such as offices, factories, classrooms, hospitals and hotels. Displays readings on a bright green LED display with 2½” high CO2 digits.
Also indicates general CO2 levels with green (good), yellow (fair), and red (poor) LED lights. User may set a maximum CO2 audible alarm and adjust temperature and RH readings to match any standard. Automatic Baseline Calibration (ABC) and maintenance free NDIR (non-dispersive infrared) CO2 sensor ensure long-term accuracy, stability and reliability. Can be wall mounted, or will stand on a shelf or desktop. Includes AC adaptor.
Dimensions: 12″ × 8½” × 2″ (304 × 216 × 51 mm)
Weight: 2.9 lbs (1315 g)
Range | Resolution | Accuracy | |
Temperature: | 0 to 50°C 32 to 122°F | 0.1°C & F | ±1°C (0 to 40°C) otherwise ±1.5°C |
RH: | 0.0% to 99.9% | 0.1% | ±5% RH (@25°C & 10 to 90% RH) otherwise ±7% RH |
CO2: | 0 to 9,999 ppm | 1 ppm | ±75 ppm +5% of rdg |
Operating Temperature RH: | 32 to 122°F 0 to 50°C <80% RH | ||
Storage Temperature: | -40 to 158°F -40 to 70°C |
Standards
Carbon Dioxide (CO2) Levels and Exposure Effects | |
250 to 350 ppm | Background (normal) outdoor air level. |
350 to 1,000 ppm | Typical level found in occupied spaces with good air exchange. |
1,000 to 2,000 ppm | Level associated with complaints of drowsiness and poor air. |
2,000 to 5,000 ppm | Level associated with headaches, sleepiness, and stagnant, stale, stuffy air. Poor concentration, loss of attention, increased heart rate and slight nausea may also be present. |
> 5,000 ppm | Exposure may lead to serious oxygen deprivation resulting in permanent brain damage, coma and even death. |
Backlit dual display enables you to choose between an upper display of air velocity, RH or CO2 and a lower display of air temperature, air volume, dew point or wet bulb temperature. Calculates min/max, multi-point and time weighted average on all parameters and has a hold function. View readings on your smartphone in real time via Bluetooth with free iOS and Android apps and export a summary the data together for later analysis. The app will also superimpose current readings of all parameters on your smart phone photo of the object being measured. Simple user calibration of CO2 and RH.
Also enables input of air pressure for accurate compensation of CO2 measurements. The CO2 sensor uses NDIR (non-dispersive infrared) waveguide technology to ensure long-term accuracy, and reliability. Comes in a hard carrying case with 4 AAA batteries.
Optional Air Cones
Air cones come in a set with one round cone for vents smaller than 7 ½” diameter, and one square cone for vents smaller than 12 ½” x 12 ½”. When attached to the cone the meter automatically calculates air volume without the need to input vent size. The optional extension rod can be used with the meter alone, or the cone, eliminating the need for a ladder.
Dimensions: 10½” × 4″ × 2″ (269 × 106 × 51 mm)
Weight: 7 oz (200 g)
Probe Diameter: 4″ (140mm)
Range | Resolution | Accuracy | |
---|---|---|---|
Air Speed | 0.20 to 30 m/s | 0.01 | ±1.5% rdg + 0.3 m/s (<20 m/s) |
Air Temperature | 14 to 140°C -10 to 60°F | 0.01 | 0.9°F 0.6°C |
Air Volume | 0 to 99999 m3/s (0 to 99999 cfm) | 0.1 (0-9999.9) or 1 (10000-99999) | |
RH | 0.1 to 99.9% | 0.01 | ±3% (10 to 90%) otherwise ±5% |
Dew Point | 8 to 140°F -5 to 59.5°C | 0.1 | |
Wet Bulb | -100 to 140°F -20 to 59.9°C | 0.1 | |
CO2 | 0 to 5000 ppm | 1 ppm | ±30 ppm ±5% of rdg |
Easily portable and designed for simple one-hand operation.
Reads oxygen in air for environmental studies, IAQ, bio-technology (for oxygen incubators and anaerobic cultivators), food storage and refrigeration, and testing fire alarm and fuel cell systems.
The fast, highly reliable, galvanic oxygen sensor is unaffected by acidic gases such as CO2. Simultaneously displays O2 concentration and air temperature in °C or °F. Features hold, min/max, a low battery indicator, ATC and auto-power-off. Comes with 4 AAA batteries and a soft carrying case with a belt loop and shoulder strap.
Dimensions: 7″ × 1½” × 1½” (178 × 38 × 38 mm)
Weight: 5.3 oz (150 g).
| Range | Resolution | Accuracy |
O2 | 0 to 30% | 0.1% | ± (1% reading + 0.2% O2) |
Temperature | 32 to 122°F 0 to 50°C | 0.1° | 1.5°F± 0.8°C |
Standards
Oxygen (O2) Levels and Exposure Effects | |
>23.5% | Significant fire and explosion risk |
19.5% | Minimum acceptable oxygen level. |
15 to 19% | Decreased ability to work strenuously. Impair coordination. Early symptoms. |
12 to 14% | Respiration increases. Poor judgment |
10 to 12% | Respiration increases. Lips blue. |
8 to 10% | Mental failure. Fainting. Nausea. Unconsciousness. Vomiting. |
6 to 8% | 8 minutes – fatal. 6 minutes – 50% fatal 4-5 minutes – possible recovery. |
4 to 6% | Coma in 40 seconds. Death |
Monitor Indoor Air Quality (IAQ) in public spaces with potentially high levels of CO2 (carbon dioxide).
Poor air quality may cause tiredness, inability to concentrate, and even illness (i.e., Sick Building Syndrome). This instrument is ideal for monitoring indoor air quality in crowded public spaces with potentially high levels of CO2 (carbon dioxide) such as offices, factories, classrooms, hospitals and hotels. The same measurement parameters can also be used to test air from HVAC equipment. Backlit simultaneous display of CO2 level, humidity and air temperature, or the user may choose a rotating display of dew point and wet bulb temperature instead of air temperature. Also calculates TWA (Time Weighted Average) and STEL (Short-Term Exposure Limit). Simple user calibration of CO2 and RH. Features audible CO2 threshold alarms, min/max/avg, hold and a computer interface. NDIR (non-dispersive infrared) technology ensures long-term accuracy, stability and reliability. In order to connect this model to a computer to stream data, you will need the USB Cable 840054 and Data Acquisition Software 840052. Comes in a hard carrying case with 4 AA batteries. Uses optional AC Adapter (840027).
Dimensions: 8½” × 2¾” × 2¼” (216 × 70 × 57 mm)
Weight: 9.6 oz (272 g)
Range | Resolution | Accuracy | |
Air Temperature | 14 to 140ºF -10 to 60ºC | 0.1 | 0.9ºF 0.6ºC |
RH | 0 to 100% | ±3% (10 to 90%) ±5% (otherwise) | |
Dew Point | 8 to 140ºF -13.3 to 60ºC | ||
Wet Bulb | -100 to 140ºF -73.4 to 60ºC | ||
CO2 | 0 to 5000 ppm | 1 ppm | ±30 ppm ±5% rdg |
Carbon Dioxide (CO2) Levels and Exposure Effects | |
250 to 350 ppm | Background (normal) outdoor air level. |
350 to 1,000 ppm | Typical level found in occupied spaces with good air exchange. |
1,000 to 2,000 ppm | Level associated with complaints of drowsiness and poor air. |
2,000 to 5,000 ppm | Level associated with headaches, sleepiness, and stagnant, stale, stuffy air. Poor concentration, loss of attention, increased heart rate and slight nausea may also be present. |
> 5,000 ppm | Exposure may lead to serious oxygen deprivation resulting in permanent brain damage, coma and even death. |
Poor air quality may cause tiredness, inability to concentrate, and even illness (i.e., Sick Building Syndrome). This instrument is ideal for measuring indoor air quality in crowded public spaces with potentially high levels of CO2 (carbon dioxide) such as offices, factories, classrooms, hospitals and hotels. The same measurement parameters can also be used to test air from HVAC equipment. Recalls the maximum and minimum CO2 readings and has a user selectable audible maximum alarm. Automatic Baseline Calibration (ABC) and maintenance free NDIR (non-dispersive infrared) CO2 sensor ensure long-term accuracy, stability and reliability. Calibrates to air and has a hold function. Records up to 32,000 data points of temperature, RH and CO2 that can be downloaded using a USB cable and software (included).
Comes complete with tripod screw, soft carrying case, 6 AAA batteries, AC Adapter (800059), USB computer cable and downloadable software. Please click the software download link above.
Range | Resolution | Accuracy | |
Temperature | -10 to 50°C 14 to 122°F | 0.1°C/F | ±1°C (±2°F) |
RH | 10% to 90% | 0.1% | ±5% (@25°C) |
CO2 | 0 to 9999 ppm | 1 ppm | ±75 ppm +5% of rdg (0 to 5000 ppm) |