This multi-test vial is designed to be used with the water bath, heat block or the Toxinometer®. With this configuration, the user dispenses 0.1 mL of dissolved LAL reagent into the appropriate reaction tube, then adding in 0.1 mL of the sample. This multi-test vial is ideal for a user testing a larger number of samples.
PYROSTAR™ ES-F 80 TEST KIT4 multi-test vials (2.0 mL) + 1 vial CSE (500 ng/vial) | ||
Catalog number | Gel Clot Sensitivity (EU/mL) | Kinetic Turbidimetric Quantitative Range (EU/mL)
|
WPEK4-20015 | 0.015 | 0.001 to 10 |
WPEK4-20003 | 0.03 | 0.01 to 10 |
WPEK4-20006 | 0.06 | |
WPEK4-20125 | 0.125 | |
WPEK4-20025 | 0.25 |
PYROSTAR™ ES-F 200 TEST KIT4 multi-test vials (5.2 mL) + 1 vial CSE (500 ng/vial) | ||
Catalog number | Gel Clot Sensitivity (EU/mL) | Kinetic Turbidimetric Quantitative Range (EU/mL) |
WPEK4-50015 | 0.015 | 0.001 to 10 |
WPEK4-50003 | 0.03 | 0.01 to 10 |
WPEK4-50006 | 0.06 | |
WPEK4-50125 | 0.125 | |
WPEK4-50025 | 0.25 |
PYROSTAR™ ES-F 2.0 ML BULK KIT100 multi-test vials (2.0 mL) | ||
Catalog number | Gel Clot Sensitivity (EU/mL) | Kinetic Turbidimetric Quantitative Range (EU/mL)
|
WPEM-20015 | 0.015 | 0.001 to 10 |
WPEM-20003 | 0.03 | 0.01 to 10 |
WPEM-20006 | 0.06 | |
WPEM-20125 | 0.125 | |
WPEM-20025 | 0.25 |
PYROSTAR™ ES-F 5.2 ML BULK KIT100 multi-test vials (5.2 mL) | ||
Catalog number | Gel Clot Sensitivity (EU/mL) | Kinetic Turbidimetric Quantitative Range (EU/mL)
|
WPEM-50015 | 0.015 | 0.001 to 10 |
WPEM-50003 | 0.03 | 0.01 to 10 |
WPEM-50006 | 0.06 | |
WPEM-50125 | 0.125 | |
WPEM-50025 | 0.25 |
Single-test vials come with pre-dispensed LAL reagent for a single measurement. This configuration is used by adding 0.2 mL of the sample directly to the reaction vial containing the lyophilized reagent. This single-test vial is designed to be used with our Toxinometer® Measurement System (Toxinometer®) to assist labs transitioning from a gel clot to a kinetic turbidimetric methodology. The single-test configuration is ideal to assay a small number of samples or for a less-experienced user.
PYROSTAR™ ES-F SINGLE-TEST KIT | ||
25 single-test vials + 1 vial CSE (500 ng/vial) | ||
Catalog Number | Gel Clot Sensitivity (EU/mL) | Kinetic Turbidimetric Quantitative Range (EU/mL) |
WPESK-0015 | 0.015 | 0.001 to 10 |
WPESK-0003 | 0.03 | 0.01 to 10 |
WPESK-0125 | 0.125 | 0.01 to 10 |
WPESK-0025 | 0.25 | 0.01 to 10 |
This multi-test vial is designed to be used with the microplate reader. To use this configuration, dispense 0.05 mL of the sample into microplate following 0.05 mL of dissolved LAL reagent. This assay is ideal for testing a larger number of samples in one run.
PYROSTAR™ ES-F/PLATE 160 TEST KIT4 multi-test vials (2 mL) + 1 vial CSE (500 ng/vial) | |
Catalog number | Kinetic Turbidimetric Quantitative Range (EU/mL) |
WPEPK4-20015 | 0.01 to 10 |
PYROSTAR™ ES-F/PLATE 400 TEST KIT4 multi-test vials (5.2 mL) + 1 vial CSE (500 ng/vial) | |
Catalog number | Kinetic Turbidimetric Quantitative Range (EU/mL) |
WPEPK4-50015 | 0.01 to 10 |
This multi-test vial is designed to be used with the Toxinometer® or a microplate reader.
To use this configuration with a microplate reader, dispense 0.05 mL of the sample into a microplate containing 0.05 mL of dissolved LAL reagent. When utilizing the Toxinometer®, the user dispenses 0.1 mL of dissolved LAL reagent into the appropriate reaction tube followed by 0.1 mL of the sample. The multi-test vial is ideal for a user with a larger number of samples or products that are turbid.
LIMULUS COLOR KY TEST KIT3 multi-test vials (2.0 mL) + 1 vial CSE (500 ng/vial) | ||
Catalog number | Kinetic Chromogenic | Number of Tests |
291-53101 | 0.0005 to 5 | 60 tests |
Limulus Color KY single-test vials come with pre-dispensed LAL reagent for a single measurement. This configuration is used by adding 0.2 mL of the sample directly to the reaction vial containing the lyophilized reagent. This single-test vial is ideal for user testing a smaller number of samples or one that is less-experienced.
LIMULUS COLOR KY TEST KIT25 single-test vials + 1 vial CSE (500 ng/vial) | ||
Catalog number | Kinetic Chromogenic Quantitative Range (EU/mL) | Number of Tests |
291-53601 | 0.0002 to 2 | 25 tests |
The Limulus PS Single Test is composed of LAL endotoxin-specific single-test vials and an affinity resin suspension called PyroSep™, designed to overcome any product interference by adsorbing potential endotoxin in samples while washing away the inhibitory components. When using this product, the endotoxin in the sample is adsorbed onto a capillary column filled with PyroSep™ (an affinity adsorbent with histidine bound to a water-insoluble support via a spacer). Inhibitory substances contained in the sample are washed away, allowing the adsorbed endotoxin to be measured with the single-test format LAL reagent.
LIMULUS PS SINGLE TEST | |
Catalog Number | Contents
|
299-54501 | 20 LAL ES single-test vials PyroSep™ resin suspension LAL reconstitution solution Wash solution Sample diluent 20 glass capillary columns |
PS ACCESSORY KIT (OPTIONAL) | |
294-33311 | 12 syringes (20 mL) 12 T-shape stopcocks R Type 20 Dedicated adapters 12 Bulldog clips 25 Polystyrene tubes (5 mL) 25 Polystyrene tubes (14 mL) Test tube rack |
Q: Is this test easy to perform for users with no experience in LAL testing?
A: This test is a bit more complex; it includes one extra step to ensure that the endotoxin is removed from the sample. It is more suitable for users experienced with endotoxin testing.
Q: Can this product be used with PYROSTAR™ ES-F Single?
A: No, this product cannot be used with PYROSTAR™ ES-F.