The most accurate refractometer in the world is now even more stylish, smart, and functional, Featuring intuitive touch screen technology, the new RX-i series makes navigation and selection a breeze. The RX-i series come with newly added functions, such as USB flash drive and self-diagnosis capability.
This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. The warranty period can be extended to three (3) years if the product is registered with ATAGO.
FDA 21 CFR Part 11 Software Included in Standard Delivery.
| Model | RX-5000i-Plus |
|---|---|
| Cat.No. | 3275 |
| Range | Refractive index (nD) : 1.324200 to 1.580000 Brix : 0.000 to 100.000% |
| Resolution | Refractive index (nD) : 0.000001 Brix : 0.001% Temperature: 0.01°C |
| Accuracy | Refractive index (nD) : ±0.000020 Brix : ±0.010% |
| Temperature control range | 5.00 to 75.00°C |
|---|---|
| Dimensions & Weight | 37×26×14cm, 6.6kg |
| Output | • Printer (for ATAGO digital printers) • Computer -USB |
| Warranty | 2 years standard (3 years with product registration) excluding touchscreen |
| Pre-programmed special scales | Glucose Fructose HFCS-55 HFCS-42 Inverted Sugar Honey moisture Hydrogen peroxide Sodium hydroxide Sodium chloride(w/w) Sodium chloride(w/v) Salinity Ethyl alcohol(w/w) Ethyl alcohol(v/v) Ethylene glycol Propylene glycol Glycerin Urea Urine S.G. Copper sulfate S.G. Vol%FSII(fuel system icing inhibitor)based on ASTM D5006 |
The most accurate refractometer in the world is now even more stylish, smart, and functional,featuring intuitive touch screen technology, the new RX-i series makes navigation and selection a breeze.The RX-5000i measures with the same accuracy level as the RX-5000α ±0.03% Brix and ±0.00004 nD.The RX-i series come with newly added functions, such as USB flash drive and self-diagnosis capability.This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. The warranty period can be extended to three (3) years if the product is registered with ATAGO.FDA 21 CFR Part 11 Software Included in Standard Delivery.
| Model | RX-5000i |
|---|---|
| Cat.No. | 3276 |
| Range | Refractive index (nD) : 1.324200 to 1.580000 Brix : 0.00 to 100.00% |
| Resolution | Refractive index (nD) : 0.000001 Brix : 0.01% Temperature: 0.01°C |
| Accuracy | Refractive index (nD) : ±0.000040 Brix : ±0.03% |
| Temperature control range | 5.00 to 75.00°C |
|---|---|
| Dimensions & Weight | 37×26×14cm, 6.6kg |
| Output | • Printer (for ATAGO digital printers) • Computer -USB |
| Warranty | 2 years standard (3 years with product registration) excluding touchscreen |
| Pre-programmed special scales | Glucose Fructose HFCS-55 HFCS-42 Inverted Sugar Honey moisture Hydrogen peroxide Sodium hydroxide Sodium chloride(w/w) Sodium chloride(w/v) Salinity Ethyl alcohol(w/w) Ethyl alcohol(v/v) Ethylene glycol Propylene glycol Glycerin Urea Urine S.G. Copper sulfate S.G. Vol%FSII(fuel system icing inhibitor)based on ASTM D5006 |
Featuring intuitive touch screen technology, the new RX-i series makes navigation and selection a breeze. The RX-i series come with newly added functions, such as USB flash drive and self-diagnosis capability.The RX-9000i features both high accuracy and wide measurement range.This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. The warranty period can be extended to three (3) years if the product is registered with ATAGO.
FDA 21 CFR Part 11 Software Included in Standard Delivery.
| Model | RX-9000i |
|---|---|
| Cat.No. | 3278 |
| Range | Refractive index (nD) : 1.299800 to 1.715000 Brix : 0.00 to 100.00% |
| Resolution | Refractive index (nD) : 0.000001 Brix : 0.01% Temperature : 0.01°C |
| Measurement Accuracy (nD) | ±0.000040 (nD 1.33299 to1.42009 at 10.00 to 30.00°C) ±0.00010 (For ranges other than the above) |
|---|---|
| Measurement Accuracy Brix | ±0.03% ±0.05% (For the Brix 50.01 to 95.00%) (Temp at 10.00 to 30.00°C) |
| Temperature control range | 5.00 to 75.00°C |
| Dimensions & Weight | 37×26×14cm, 7.0kg |
| Output | • Printer (for ATAGO digital printers) • Computer -USB |
| Warranty | 2 years standard (3 years with product registration) excluding touchscreen |
| Pre-programmed special scales | Glucose Fructose HFCS-55 HFCS-42 Inverted Sugar Honey moisture Hydrogen peroxide Sodium hydroxide Sodium chloride(w/w) Sodium chloride(w/v) Salinity Ethyl alcohol(w/w) Ethyl alcohol(v/v) Ethylene glycol Propylene glycol Glycerin Urea Urine S.G. Copper sulfate S.G. Vol%FSII(fuel system icing inhibitor)based on ASTM D5006 |
Featuring intuitive touch screen technology, the new RX-i series makes navigation and selection a breeze.The RX-i series come with newly added functions, such as USB flash drive and self-diagnosis capability.The RX-7000i features an even wider refractive index range than its predecessor.This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. The warranty period can be extended to three (3) years if the product is registered with ATAGO.
FDA 21 CFR Part 11 Software Included in Standard Delivery.
| Model | RX-7000i |
|---|---|
| Cat.No. | 3279 |
| Range | Refractive index (nD) : 1.299800 to 1.715000 Brix : 0.00 to 100.00% |
| Resolution | Refractive index (nD) : 0.000001 Brix : 0.01% Temperature: 0.01°C |
| Accuracy | Refractive index (nD) : ±0.000100 Brix : ±0.1% |
| Temperature control range | 5.00 to 75.00°C |
|---|---|
| Dimensions & Weight | 37×26×14cm, 7.0kg |
| Output | • Printer (for ATAGO digital printers) • Computer -USB |
| Warranty | 2 years standard (3 years with product registration) excluding touchscreen |
| Pre-programmed special scales | Glucose Fructose HFCS-55 HFCS-42 Inverted Sugar Honey moisture Hydrogen peroxide Sodium hydroxide Sodium chloride(w/w) Sodium chloride(w/v) Salinity Ethyl alcohol(w/w) Ethyl alcohol(v/v) Ethylene glycol Propylene glycol Glycerin Urea Urine S.G. Copper sulfate S.G. Vol%FSII(fuel system icing inhibitor)based on ASTM D5006 |
| Power Supply | Size AAA alkaline battery × 2 |
|---|---|
| International Protection Class | IP67 |
| Dimensions & Weight | 22(Φ)×490(W)mm, 400g (main unit only) |
The NEW RX-5000α (alpha)-Plus features improved accuracy over the RX-5000α-Plus, with Brix ±0.010 and nD ±0.00002. Is has a thermo-module to control temperature, a constant temperature water bath is not necessary.It displays the top-and-bottom-limit-bar for your set control range.FDA 21 CFR Part 11 Software Included in Standard Delivery.This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. The warranty period can be extended to three (3) years if the product is registered with ATAGO.
| Model | RX-5000α-Plus |
|---|---|
| Cat.No. | 3266 |
| Range | Refractive index (nD) : 1.32700 to 1.58000 Brix : 0.000 to 100.000% |
| Resolution | Refractive index (nD) : 0.00001 Brix : 0.005% Temperature : 0.01°C |
| Accuracy | Refractive index (nD) : ±0.00002 Brix : ±0.010% |
| Temperature control range | 5.00 to 60.00°C |
|---|---|
| Dimensions & Weight | 37×26×14cm, 6.4kg |
| Output | • Printer (for ATAGO digital printers) • Computer – RS-232C Connection to a USB port requires a USB to RS-232 adapter (optional) |
| Warranty | 2 years standard (3 years with product registration) |
The NEW RX-5000α (alpha)-Plus features improved accuracy over the RX-5000α-Plus, with Brix ±0.010 and nD ±0.00002. Is has a thermo-module to control temperature, a constant temperature water bath is not necessary.It displays the top-and-bottom-limit-bar for your set control range.FDA 21 CFR Part 11 Software Included in Standard Delivery.This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. The warranty period can be extended to three (3) years if the product is registered with ATAGO.
| Model | RX-5000α-Plus |
|---|---|
| Cat.No. | 3266 |
| Range | Refractive index (nD) : 1.32700 to 1.58000 Brix : 0.000 to 100.000% |
| Resolution | Refractive index (nD) : 0.00001 Brix : 0.005% Temperature : 0.01°C |
| Accuracy | Refractive index (nD) : ±0.00002 Brix : ±0.010% |
| Temperature control range | 5.00 to 60.00°C |
|---|---|
| Dimensions & Weight | 37×26×14cm, 6.4kg |
| Output | • Printer (for ATAGO digital printers) • Computer – RS-232C Connection to a USB port requires a USB to RS-232 adapter (optional) |
| Warranty | 2 years standard (3 years with product registration) |
The RX-9000α is a fully automatic digital refractometer with the highest level of accuracy of its kind. This is designed with a wide measurement range, measurement temperature range, and highest measurement accuracy, which is suitable for multiple sample types ; such as measuring oils and fats with high melting points, aroma oils of high refractive index and organic solvents, meeting demands for high accuracy measurements.It has a built-in Peltier thermo module for maintaining a constant sample temperature while taking measurements. This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. The warranty period can be extended to three (3) years if the product is registered with ATAGO.FDA 21 CFR Part 11 Software Included in Standard Delivery.
| Model | RX-9000α |
|---|---|
| Cat.No. | 3263 |
| Range | Refractive index (nD) : 1.29980 to 1.71500 Brix : 0.00 to 100.00% |
| Resolution | Refractive index (nD) : 0.00001 Brix : 0.01% Temperature: 0.01°C |
| Accuracy | Refractive index(nD): ±0.00004 (0.00010 for the nD higher than 1.42009) Brix±0.03% (±0.05% for the Brix higher than Brix 50.01) |
| Temperature control range | 5.00 to 70.00°C |
|---|---|
| Dimensions & Weight | 37×26×14cm, 6.8kg |
| Output | • Printer (for ATAGO digital printers) • Computer – RS-232C Connection to a USB port requires a USB to RS-232 adapter (optional) |
| Warranty | 2 years standard (3 years with product registration) |
The RX-7000α (alpha) is an improved (upgraded) model for a measurement range of refractive index and measurement temperature of an RX-5000α (alpha). The thermo module for constant temperature is equipped.It is best for measuring oils and fats of high melt point, higher refractive index perfumes, organic solvents, etc.
This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. The warranty period can be extended to three (3) years if the product is registered with ATAGO.
FDA 21 CFR Part 11 Software Included in Standard Delivery.
| Model | RX-7000α |
|---|---|
| Cat.No. | 3262 |
| Range | Refractive index (nD) : 1.29980 to 1.71500 Brix : 0.00 to 100.00% |
| Resolution | Refractive index (nD) : 0.00001 (0.0001)* Brix : 0.01% (0.1%)* Temperature: 0.01°C |
| Accuracy | Refractive index (nD) : ±0.0001 Brix : ±0.1% |
| Temperature control range | 5.00 to 70.00°C |
|---|---|
| Dimensions & Weight | 37×26×14cm, 6.8kg |
| Output | • Printer (for ATAGO digital printers) • Computer – RS-232C Connection to a USB port requires a USB to RS-232 adapter (optional) |
| Warranty | 2 years standard (3 years with product registration) |
The NEW RX-007α (alpha) is suitable for measuring water soluble samples with very low concentrations (5.000% or less) such as tea (green tea, black tea, oolong tea) and low sugar beverages at a very high accuracy of ±0.005%.This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. This warranty does not cover or apply to the prism. The warranty period can be extended to three (3) years if the product is registered with ATAGO.
FDA 21 CFR Part 11 Software Included in Standard Delivery.
| Model | RX-007α |
|---|---|
| Cat.No. | 3921 |
| Range | Brix : 0.000 to 5.000% Refractive index (RI) : 1.330150 to 1.341500 |
| Resolution | Brix : 0.001% Refractive index (RI) : 0.000001 Temperature : 0.01°C |
| Accuracy | Brix : ±0.005% Refractive index (RI) : 0.000010 (at 20°C) (under specified ambient temperature and constant temperature) |
| Temperature control range | 15.00 to 30.00°C |
|---|---|
| Dimensions & Weight | 37×26×14cm, 6.7kg |
| Output | • Printer (for ATAGO digital printers) • Computer – RS-232C Connection to a USB port requires a USB to RS-232 adapter (optional) |
| Warranty | 2 years standard (3 years with product registration) excluding prism |
The NEW RX-5000α-Bev is a re-designed version of the conventional RX-5000α. A flat sample stage replaced the sample well to make it easier to wipe off the sample and to allow for a faster and easier clean up. The RX-5000α-Bev is ideal for measuring beverages and is equipped with all the standard features of the RX-5000α.
This product comes standard with a two (2) year limited warranty against manufacturer’s defects from the date of the original purchase. The warranty period can be extended to three (3) years if the product is registered with ATAGO.
FDA 21 CFR Part 11 Software Included in Standard Delivery.
| Model | RX-5000α-Bev |
|---|---|
| Cat.No. | 3271 |
| Range | Refractive index (nD) : 1.32700 to 1.58000 Brix : 0.000 to 100.00% |
| Resolution | Refractive index (nD) : 0.00001 Brix : 0.01% Temperature: 0.01°C |
| Accuracy | Refractive index (nD) : ±0.00004 Brix : ±0.03% |
| Temperature control range | 5.00 to 60.00°C |
|---|---|
| Dimensions & Weight | 37×26×14cm, 6.1kg |
| Output | • Printer (for ATAGO digital printers) • Computer – RS-232C Connection to a USB port requires a USB to RS-232 adapter (optional) |
| Warranty | 2 years standard (3 years with product registration) |
This model measures solutions of low concentration up to 2% at an extremely high accuracy level of ±0.005%. It is recommended for such samples as unsweetened tea and surfactants.2 types of solutions – distilled water as the standard solution and the sample liquid to be measured – are injected into the instrument with syringes.By using a standard solution other than distilled water, solutions of higher concentration can also be measured.
| Model | DD-7 |
|---|---|
| Cat.No. | 3930 |
| Range | 0.000 to 2.000% for sucrose solution.it is possible to measure samples with refractive index up to 1.50 (nD) by reference solutuion. |
| Resolution | Brix : 0.001% |
| Accuracy | Brix : ±0.005 (for sucrose solution at 30°C) |
| Method of measurement | Differential optical refraction |
|---|---|
| Measurement Temperature | 15.00 to 40.00℃ |
| Dimensions & Weight | 36×35×14cm, 6,2kg |
| Output | • Digital Printer DP-AD (Optional) • RS-232C |