Gas detection in a compact body
Employs a highly sensitive controlled potential electrolysis method used for electrochemical analysis. It is able to accurately detect even the faintest amount of carbon monoxide.
| Measurement range | 0 – 300 ppm (enhanced range : 301 – 1999 ppm) |
|---|---|
| Measurement method | Controlled potential electrolysis method |
| Sampling method | Diffusion |
| Indicating accuracy | +/- 5% of full scale at time of calibration |
| Operating Temperature / Humidity range | Temperature : -10 – 40 ℃ Relative humidity : 30 – 90 %RH |
| Weight | 60g(including batteries) |
| Dimensions | 77(W) x 21(D) x 42(H) mm(Excluding protrusions) |
Comes with controlled potential electrolysis sensor.
Carbon monoxide detector employs a highly sensitive controlled potential electrolysis method used for electrochemical analysis. It is able to accurately detect even the faintest amount of carbon monoxide.
| Measurement range | 0 – 300ppm (enhanced range: 301 – 999ppm) |
|---|---|
| Measurement method | Controlled potential electrolysis method |
| Sampling method | Diffusion |
| Indicating accuracy | +/- 10% of full scale at time of calibration |
| Display | Digital LCD |
| Explosion proof | Certified by Japan Ministry of Health, Labour and Welfare (Class Ex ia ⅡC T3 Ga / Certification No.TC22880) |
| Operating Temperature / Humidity range | Temperature : -10 – 40 ℃ Relative humidity : 30 – 90 %RH |
| Power source | One AAA alkaline battery provides about 3500 hours of operation (when no alarm signal is emitted) |
| Dimensions | 48(W) x 37(D) x 105(H) mm |
| Weight | 110g |