Fully automatic and cloud-enabled extractors, available in 3 and 6 positions that guarantee security, accuracy and precision in the determination of extractable matter according to Randall and Twisselmann.
The SER 158 Series automatic solvent extractors in 3 and 6 positions are the accurate and precise solution for quantitative and qualitative extractable matter determination according to Randall method, analyzing up to 5 times faster than traditional Soxhlet.
The solid-liquid extraction process removes the soluble components from solids using a liquid solvent in 5 steps. The SER 158 works in accordance with international standards such as AOAC, ISO, EPA, APHA, UNI.
Safe and powerful heating combined with advanced software and security processes guarantee reproducible extraction processes.
SER 158 is fully automated to maximize productivity and free operator time. Just Load&Go!
The exclusive 7″ ControlPadTM of the SER 158 has an intuitive User Interface that facilitates the set-up and interaction with the analyzer.
The SER 158 is designed to work unattended 24/7 with Load&Go technologies, minimizing necessary operator intervention. Integrated yet removable, the ControlPadTM can be connected with a balance and barcode reader for maximum automation and traceability.
Choose from the pre-installed methods, create new ones and mark your favorites for a fast start-up. Each extraction step is visualized on the ControlPadTM along with a great set of information and options.
Results are immediately calculated and stored on the on-board memory. Three USB ports are available along with an Ethernet connection for data transfer to external devices.
The SER 158 safe SolventXpress™ technology allows smart solvent dispensing for solvent addition guaranteeing minimum exposure to solvents and ensuring operator safety.
The condensed solvent at the end of the analysis is collected in the cooled recovery tank in the back of the instrument and the solvent output is completely automatic with one click on the ControlPadTM.
The SER 158 is hermetically sealed and the protective transparent cover preserves from spills and hot solvents. Advanced sensors constantly monitor the extraction process and ensure a safe analysis during all the steps.
SafeEnd™ technology of the SER 158 prevents extracted matter burnings automatically raising the cups after the removing step.
The SER 158 compact design saves precious space in your lab and especially under the fume hood!
The SER 158 is the best in its category in terms of space savings thanks to VELP engineering and the completely automatic analysis step and solvent management.
The SER 158 is designed to work automatically and unattended and with the connectivity option to VELP Ermes cloud platform, you will be able to monitor and control your analyses from a virtual cockpit wherever you are, anytime you need to avoiding routine instrument check and download of data.
VELP Ermes is available for PC, smartphone and tablet.
115-230 V / 50-60 Hz
cod. S303A0380
115-230 V / 50-60 Hz
cod. S303A0390
115-230 V / 50-60 Hz
cod. F303A0380
115-230 V / 50-60 Hz
cod. F303A0390
The SER 158 automatic solvent extractor is equipped with a wide range of accessories designed to make its daily use as easy as possible and guarantee a high versatility of use.
Choose your preferred size of glasses and thimbles as well as gaskets made of high-quality materials that can be adapted to any application, as in the case of the high-quality Vaflon, which is suitable for a very wide range of solvents.
In addition to the standard accessories, the SER 158 extractor has several optional accessories to satisfy every need and guarantee the execution of the analysis in maximum safety.
POSITIONS: | SER 158/3 3-positions SER 158/6 6-positions |
MAX. CAPACITY: | SER 158/3 21 samples/day/unit SER 158/6 42 samples/day/unit |
SCALABILITY: | SER 158/3 12-pos. (up to 4 units) SER 158/6 24-pos. (up to 4 units) |
DISPLAY: | 7” color touch screen – extractable ControlPad |
ACCEPTED SOLVENTS: | Capable of being used with the majority of solvents |
SOLVENT RECOVERY: | > 90% |
MEASUREMENT RANGE: | 0.1-100% |
REPRODUCIBILITY (RSD): | ≤ 1% |
AUTOMATION: | Immersion, Removing, Washing, Recovery, Cooling |
LIGHTING: | LED lights show active positions |
HEATING ELEMENT: | Glass ceramic – positions independent switch on/off |
SAMPLE SIZE: | 0.5 to 15 g in 33×80 mm thimbles (generally 2-3 g) |
SEALS: | Viton, Butyl, and Vaflon |
CONDENSERS: | Titanium (VELP Patent Pending) |
CONNECTIVITY: | Cloud via LAN |
INTERFACES: | 3 x USB (balance, mouse, USB stick), Ethernet (Pc) |
RESULT CALCULATION: | Automatic, Archived on ControlPad |
WATER CONSUMPTION: | from 1.0 l/min |
DIMENSIONS (WXHXD): | SER 158/3 358x546x450 mm – 14×21,5×17,7 inch SER 158/6 546x546x450 mm – 21,5×21,5×17,7 inch |
DIMENSIONS WITH CONTROLPAD: | SER 158/3 358x546x570 mm – 14×21,5×22,4 inch SER 158/6 546x546x570 mm – 21,5×21,5×22,4 inch |
WEIGHT (SER 158/CONTROLPAD): | SER 158/3 Kg 29 / 1 – 64 / 2,2 lb SER 158/6 Kg 36 / 1 – 80,3 / 2,2 lb |
POWER SUPPLY: | SER 158/3 115/230 – 50/60 V-Hz SER 158/6 115/230 – 50/60 V-Hz |
POWER CONSUMPTION: | SER 158/3 630/850 W SER 158/6 630/850 W |
Solvent extraction system suitable for the separation of a substance or a group of elements from solid and semi-solid samples according to the Randall technique.
The SER 148/3 and SER 148/6 can be used to separate a substance or a group of elements from solid and semi-solid samples according to the Randall technique (consisting of Immersion, washing and solvent Recovery).
As for the automatic version SER 158, the main field of application is the determination of the content of soluble products such as fats, detergents, plasticizers and pesticides in food, animal feeds, detergents, rubber and plastic formulas, pharmaceutical products, soil.
The SER 148 Series is a semi-automatic solution with no compromises on operator safety (IP55) and solvent consumption also guaranteeing a limited cost per analysis.
Combined to HU6 Hydrolysis Unit, is possible to use the same crucibles to prevent any possible sample loss between the two units.
Perform single or multiple solvent extractions with Randall method, an improvement of Soxhlet technique, as hot solvents are used to speed up the analysis. In fact, the fast solubilization made by hot solvent permits a considerable reduction of the extraction time (approx. 90 minutes).
The extraction is made by immersion of the sample in the boiling solvent, followed by a rinsing phase with cold solvent.
Maximum reproducibility is ensured, as well as a high recovery rate of the solvent used.
SER Series can be used with a wide range of sample types and with a variety of solvents, for increased flexibility.
230 V / 50-60 Hz
cod. F30300240
115 V / 50-60 Hz
cod. F30310240
230 V / 50-60 Hz
cod. F30300242
115 V / 50-60 Hz
cod. F30310242
cod. A00000308
cod. A00000309
cod. A00000142
cod. A00001142
cod. A00000313
cod. A00001145
cod. A00000073
cod. A00000318
cod. A00001147
cod. A00001009
cod. A00000011
cod. A00000310
cod. A00001149
cod. A00000061
cod. A00000307
NUMBER OF SAMPLES: | SER 148/3 3 positions SER 148/6 6 positions |
2 DISPLAYS: | working temperature / settable parameters |
REPRODUCIBILITY (RSD): | ≤ 1% |
SOLVENT RECOVERY: | from 50 to 75% |
MAX VOLUME EXTRACTION CUP: | 150 ml |
NUMBER OF PROGRAMS: | 29 |
WORKING TEMPERATURE: | from 100 to 260 °C |
COOLING WATER: | 2 l/min |
SAMPLE QUANTITY: | from 0,5 to 15 g (generally 2-3 g) |
SOLVENT VOLUME: | from 30 to 100 ml |
IMMERSION TIME: | from 0 to 999 minutes |
WASHING TIME: | from 0 to 999 minutes |
RECOVERY TIME: | from 0 to 999 minutes |
CONSTRUCTION MATERIAL: | epoxy painted stainless steel structure |
DIMENSIONS (WXHXD): | SER 148/3 480x620x390 mm (18.9×24.4×15.4 in) SER 148/6 700x620x390 mm (27.6×24.4×15.4 in) |
WEIGHT: | SER 148/3 30 Kg (66 lb) SER 148/6 40 Kg (88 lb) |
POWER: | SER 148/3 500 W SER 148/6 950 W |
Optimum solution for the acid/basic hydrolysis of food and feed samples prior to solvent extraction for total fat analysis.
The VELP Scientifica Hydrolysis Unit HU 6 is the ideal solution for the prior to solvent extraction for the determination of the total fat content, in order to free the fat molecules ready for extraction.
This procedure is required in a number of AOAC Official Methods to determine the fat content of food samples such as meat, cheese, seafood, chocolate, cereal flours, etc.
The HU 6 performs hydrolysis in complete safety and handles six samples at the same time in order to maximize productivity.
230 V / 50-60 Hz
cod. F30300110
115 V / 50-60 Hz
cod. F30310110
CONSTRUCTION MATERIAL: | epoxy painted stainless steel structure |
NUMBER OF SAMPLES: | 6 samples |
SET TEMPERATURE: | display visualization |
COUNTDOWN: | display visualization |
DISPLAY: | LCD |
NUMBER OF PROGRAMS: | 20 |
SELECTABLE LANGUAGE: | I, F, UK, E, D, T |
TEMPERATURE RANGE: | from room temp. to 200 °C |
TEMPERATURE CALIBRATION: | automatic |
STABILITY OF THE HEATING BLOCK TEMPERATURE: | ± 0,5°C |
HOMOGENEITY OF THE HEATING BLOCK TEMPERATURE: | ± 0,5°C |
PRECISION OF THE HEATING BLOCK TEMPERATURE: | ± 0,5°C |
REACHING OF SET TEMPERATURE: | acoustic and visual signal |
POWER: | 1350 W |
DIMENSIONS (WXHXD): | 355x590x450 mm (14.0×23.2×17.7 in) |
WEIGHT: | 14.5 Kg / 32.0 lb |