The medical waste treatment workstation is based on microwave disinfection, steam as a supplement to microorganisms undifferentiated disinfection. It can realize a series of operations from waste input, crushing, disinfection, pumping and discharging, etc. The treated waste can directly enter the domestic waste for power generation or burial. The device is reserved for IoT big data interface, which is convenient for users to read data remotely and understand the real-time status of machine operation.
•The use of imported high-strength, highly wear-resistant blades
•Crushing particle size up to 2cM
• Adopt microwave + high temperature steam double action
• The killing rate of microorganisms such as spores can reach log6
• Disinfection process without harmful gases and wastewater generation microwave
• Real-time monitoring of leaks in the sterilization uni
• At the same time with sound and light alarm
• Abnormal alarm and stop protection
• Reserved GPS+GDS positioning, double guarantee sterilization
• Full process display, data collection
Model | Voltage (V) | Dimensions | Rating | Net Weight |
YFXDG200 | 380V/50 | 2240 x 1640 x 1460(1080)mm | 14KW | <1t |
Secure, Fast & Reliable Vaccination Facility Guaranteed Vaccination Safety
It is suitable for vaccination in vaccination centers, hospitals, CDC, schools, large enterprises and other institutions; the shelter is movable and applicable for vaccinating in large batches.
Top Layout View
The shelter is divided into three areas:registration area, vaccination area and cold chain area. Pre-check and registration of vaccination are conducted in the registration area. Vaccination is carried out in the vaccination area, and solar direct drive refrigerator is placed in the cold chain area.
Independent monitoring of each operation area to achieve real-time supervision and inspection of the whole process of vaccination.
Equipped with air purification sterilizer and ultraviolet disinfection, the cabin environment is safer.
Model | Power Supply(V/Hz) | Power(W) | Exterior Dimensions (W*D*H mm) | Interior Dimensions (W*D*H mm) | Temperature(ºC) | Humidity(%) | Sound Level(dB(A)) | Clean Class |
Intelligent Vaccination Shelter | 220 (110)/50 (60) | 2500 | 6,100*2,400*2,600 | 5,700*2,300*2,200 | 18~26 | 30~70 | ≤60 | ISO level 8 |
Designed for vaccination of children in remote areas, routine physical examination of pregnant women and children, water-supply station and healthcare vaccination facility.
Equipped with solar direct drive refrigerator with long holdover time
Equipped with a number of storage cabinets for storage of inoculation cotton swabs, disposable needles and other items
Independent monitoring of each operation area to achieve real-time supervision and inspection of the whole process of vaccination, diagnosis and treat
Model | Power Supply | Exterior Dimensions(W*D*H)(mm) | Interior Dimensions(W*D*H)(mm) | Solar Panel Power(W) | Nominal Capacity(Wh) | Maximum Power Output(W) |
Mobile clinic | 220/50Hz | 6100*2400*2600 | 5700*2300*2200 | 1500;Colloidal battery | 14400 | 2000 |
Layout Plan
High strength, corrosion resistance, tight sealing, and excellent thermal insulation
Model | Cabin Type | Exterior Dimensions(mm) | 24h Testing Capacity | Power Supply (V/Hz) | Clean Class |
YJF-12X1H | Single cabin | 12192x2438x2896 | 3000 | 380/50 | ISO 8 |
Interior View
Interior Layout Design
Model | Power Supply | Power(W) | Exterior Dimensions(W*D*H)(mm) | Interior Dimensions(W*D*H)(mm) | Weight(kg) |
Mobile Solar Lab | 220V/50HZ | 4000 | 10200*2250*2350 | 10000*2050*2150 | 10000 |
The unit is primarily used for daily disinfection of public places such as hospitals, community health service centers, airports, hotels and subways.
The atomization disinfection unit uses the robot as the carrier to autonomously move and deploy
multi-point disinfection tasks. This is achieved by diluting th e disinfectant to form tiny particles (mist), which can effectively kill microorganisms, bacteria, and viruses attached to the surface of an object. A ccording to the actual disinfection needs of the location, it can autonomously plan the disinfection route, and is a fully automated mobile indoor unmanned disinfection carrier. The unit can sterilize 360°within the indoor environment and can disinfect 1000m3 areas in 15 minutes, reducing manual contact and avoiding the risk of personnel infection.
Model | Remote Intelligent Control | Atomized Particle Size(μm) | The Amount of Mist | Product Weight (Kg) | Product Size (W×D×H mm) |
HBOT11A | Support | 2~5 | Rotation adjustment 800~3000mL/h | 42 | 540×360×1368 |
WBOT11U | Support | 2~5 | Three gear adjustment (1200/2000/3000mL/h) | 37 | 450×450×1360 |
This product is suitable for cold chain transportation of drugs, vaccines, biological products, medical raw materials, fresh food and other products with strict requirements on temperature control.
Double drive refrigeration system, can be powered by diesel generator or 220V AC
Safe and reliable
Firm structure, suitable for complex road conditions
Low fuel consumption, high horsepower and low transportation cost
+2°C~+8°C accurate temperature control, high uniformity
Thickened insulation layer, excellent insulation performance
The health care solution improving medical services by reaching remote and hard to reach locations, such as towns, small villages and mountainous regions.
Solution
Model | Operating Temp(°C) | Storage Temp(°C) | Vaccine Capacity(vial) | Refrigerating Volume (L) | Freezing Volume(L) | Freeze Protection Grade | Duration | Charging Time (h) | Double Tanks(L) | Fuel Consumption (L/km) | Maximum Mileage (km) |
Inoculation Refrigerator | 5~43 | 2~8 | 200 | ||||||||
Solar Direct Drive Combined Refrigerator | 300 | 37.5 | 32 | A | |||||||
Power Supply (battery) | 3 refrigerators running for 1.5days (6h/day) | 10 | |||||||||
Medical Vehicle | 10 | 18/100 | 100 |
P2+ mobile nucleic acid testing vehicle is designed and manufactured in accordance with the requirements of the enhanced BSL-2 laboratory. It can detect the nucleic acid of various pathogenic microorganisms, including the novel coronavirus, and provide a fast, safe, accurate and efficient technical inspection platform for epidemic prevention and control. It is suitable for nucleic acid detection in various emergency situations including CDC, hospitals, airports, railway and bus stations, schools and border ports.
The intelligent pressure control system ensures directional indoor airflow with the inlet air and exhaust air are filtered with high efficiency to avoid cross contamination and to satisfy the quality requirements of the nucleic acid test environment.
Model | Power Supply(V/Hz) | Power(W) | Exterior Dimensions (W*D*H mm) | Interior Dimensions (W*D*H mm) | Temperature(ºC) | Humidity(%) | Sound Level(dB(A)) | Clean Class |
P2+ Mobile Nucleic Acid Testing Vehicle | 220 (110)/50 (60) | 2500 | 6,100*2,400*2,600 | 5,700*2,300*2,200 | 18~26 | 30~70 | ≤60 | ISO level 8 |
Bacterial and viruses inactivation rate>99. 9% to reduce the infection rate of the vaccination staff; can reach class 100000 cleanliness after continuously operating for 1 hour, and release healthy negative ions, providing clean air for users to experience forest air quality. Applicable for schools, community hospitals, etc.
hydroxyl groups and active oxygen to have the bacteria, germs, viruses and mold oxidized and decomposed.
Model | Voltage (V) | Noise level dB (A) | Applicable volume (m3) | Negative ion concentration | Clean class | Ultraviolet lamp life (h) |
YKJX-Y500 | 220/50 | ≤55 | ≤60 | 3*106 | 100000 | 6000 |
• Highly sensitive infrared probe
• Noncontact measurement
• 1 second measurement
One Button Measurement in 1 Second
Memory Storage
Replaceable Battery
℃/℉ Switch
Hot Tip
LED Display
Intelligent Accurate
Automatic Shutdown
Model | Measurement range (°C) | Product Weight (g) | Memory (groups) | Power supply | Automatic power-off (s) |
AET-R1B1 | 32.0~42.2 | 88 (exclude battery) | 32 | 2*AAA (DC 3V) | 60 |
AET-R1D1 | 32.0~42.2 | 47 (exclude battery) | 32 | 2*AAA Batteries (DC 3V) | 60 |
UFR106 | 32.0~43.0 | 75(exclude batteries) | 20 | 2*AAA alkaline battery |
Applicable for the safe sample swab of biological samples in hospitals, testing institutions, high-speed trains, railway stations, airports and highway junctions.
Model | Power Supply(V/Hz) | Positive Pressure(Pa) | Filtration Class | Exterior Dimension(W*D*H mm | HEPA Class | Exterior Dimension (W*D*H mm) |
HCYC-1500 | 220/50 | >15 | H13 | 1490*1550*2410 | ||
HCYC-1200 | 220/50 | G4+U15 | 1200*1400*2700 | |||
HCYZ-160S | 110~220/50/60 | >30±5 (Infinitely adjustable-speed) | G4+H14 | 1600*1600*2200 |
Medical oxygen administered by the concentrator is beneficial to cure respiratory, heart, cardiovascular and chronic pulmonary diseases, as well as other diseases requiring concentrated oxygen as key examples.
Medical oxygen administered by the concentrator is beneficial to cure respiratory, heart, cardiovascular and chronic pulmonary diseases, as well as other diseases requiring concentrated oxygen as key examples.
High quality humidifier with 6PSI pressure release
Imported lithium molecular sieve durable, high efficiency
Operates continuously for 24h* 365days
Model | Flow (L/min) | Purity | Voltage Frequency (V/Hz) |
CP303 | 0.5-3 | 0-3L/min, 93±3% | 220/50 |
CP502 | 0.5 | 0-5L/min, 93±3% | 220/50 |
CP801 | 0-8 | 0-8L/min, 93±3% | 220/50 |
CP101 | 0-10 | 0-10L/min, 93±3% | 220/50 |
·Low-noise design
·One-button start
·Memory storage
·ABS Material +LCD big screen display
·WHO Standards
Model | Product weight (g) | Memory (groups) | Measurement range | Power supply | Automatic power-off (s) |
BSX583 | 410 (battery included) | 2*99 | 0~290mmHg (0~38.66kPa) Pulse 40~180 beats/min | 4*AA battery(DC 6V) | 30 |
U80H | 230 | 2*99 | 0-299 mmHg (0-37.30kPa) Pulse40-199 beats/min | 4*AAA batteries, 1.5 V AC adapter Input 100-240V AC 50/60Hz Output 6V DC 1A | 180 |
B15 | 292.5 | 2*120 | 280mmHg (0-37.30kPa) Pulse40-199 beats/min | 4*AA batteries, 1.5 V AC adapter Input 100-240V AC 50/60Hz Output 5V DC 1A | 60 |
Haier Biomedical Mobile Biosafety Laboratory has the characteristics of flexibility, rapid response, safety and reliability, which can quickly reach around the epidemic area,and quickly carry out the sampling, isolation and verification of diseases.
The vehicle is a laboratory of negative pressure, can achieve BSL – 2S biological safety laboratory protection level, meets the requirements of biosafety laboratory structure and facilities, equipment safety operation procedures, can protect the staff who handles materials contain pathogenic microorganism and toxins, and protect the surrounding environment from pollution.
Model | Overall dimensions of the vehicle (mm) | Vehicle weight (kg) | Wheelbase (mm) | Chassis engine maximum power (kW) | Maximum speed (km/h) |
Mobile P2 Biology Lab Unit | 11980*2500*3960 | 17700 | 1800*5600 | 228 | 89 |
Haier Biomedical Eye Surgery Vehicle is a large-scale medical vehicle that integrates an operating room, a disinfection and cleaning room and an examination room. The vehicle is equipped with professional inspection and screening equipment for eye disease screening. Cataract patients can receive professional medical services at their doorstep, even in remote areas.
Model | Overall dimensions of the vehicle (mm) | Vehicle weight (kg) | Drive form | Chassis engine maximum power (kW) | Extended box width (mm) | Maximum speed (km/h) |
Mobile Ophthalmic Surgery Unit | 9940*2470*3780 | 13500 | 4X2 | 155 | 650 | 89 |
Equipped with X-ray machine, color Doppler ultrasound, ECG, biochemistry equipment, gynecological examination bed, traditional Chinese medicine diagnosis and treatment equipment, eye, nose and throat equipment and other equipment according to requirements, to fully meet the needs of various physical examinations, and also to show the overall image and comprehensive strength of the hospital.
Chassis optional: Shandeka, Dongfeng, Qingling, Benz. Interior style, layout according to customer’s needs.
Model | Overall dimensions of the vehicle (mm) | Vehicle weight (kg) | Wheelbase (mm) | Chassis engine maximum power (kW) | Extended box width (mm) | Maximum speed (km/h) |
Mobile Medical Examination Unit | 9940*2470*3780 | 13500 | 5600 | 155 | 650 | 89 |
The mobile negative pressure ICU can provide isolation and treatment places for critical patients. It is a professional mobile ward equipped with the best nursing, treatment and rehabilitation services. The ward is equipped with air supply purification devices and exhaust air purification devices, and the virus killing rate is 99.99%.
The vehicle environment meets the requirements of cleanliness and air sanitation and disinfection in the clean room of the hospital. The purification and elimination rate of 0.3μm dust particles is as high as 99.97% and the sterilization rate is over 99.9%. It has the functions of sterilization, antibacterial, constant temperature, constant humidity, constant pressure, heat recovery, high efficiency and energy saving, which can effectively ensure the air quality and safety of the ward.
Model | Overall dimensions of the vehicle (mm) | Emission Standards | Carriage | Engine displacement (ml) |
Mobile ICU Ward Unit | 9990*2500*3840 | Chinese Standard Ⅵ、GB3847-2005 | steel structure + thermalinsulation board | 6870 |
Breast cancer and cervical cancer examination unit are equipped with an independent motor, which provides high-quality support for the realization of door-to-door physical examination and the promotion of the two cancers’ screening in remote areas. Internal configuration:Complete equipment for mammography and reprography;Ultrasound device offering state-of-the-art tissue elasticity imaging.High resolution digital video colposcope on telescopic arm;Portable device to treat cervical precancer(LEEP)
Model | Overall dimensions of the vehicle (mm) | Vehicle weight (kg) | X-ray protection | Engine standard | Fuel type |
Mobile Gynecological Examination Vehicle | 12100*2550*3800 | 25000 | lead plate | European Standard II | Diesel fuel |
As the core part of the mobile hospital, the general operating unit is the operating room for medical rescue. It is equipped with a comprehensive operating room, surgical shadowless lamps and related equipment; auxiliary devices such as oxygen supply system and air laminar flow purification device are installed, and the operating room reaches the 10,000-level purification standard.
Appendectomy, gastric resection, intestinal incision, thyroidectomy, hernia incision, cholecystectomy, tumor removal, internal fixation of fractures, and gynecological midwifery and other aseptic operations.
Model | Overall dimensions of the vehicle (mm) | Vehicle weight (kg) | Inner size (mm) | Extended box width (mm) | Maximum speed (km/h) |
Mobile General Surgery Unit | 11990*2500*3970 | 13500 | 9307*2365*2105 | 900 | 89 |
As the core part of the mobile hospital, the general operating unit is the operating room for medical rescue. It is equipped with a comprehensive operating room, surgical shadowless lamps and related equipment; auxiliary devices such as oxygen supply system and air laminar flow purification device are installed, and the operating room reaches the 10,000-level purification standard.
Appendectomy, gastric resection, intestinal incision, thyroidectomy, hernia incision, cholecystectomy, tumor removal, internal fixation of fractures, and gynecological midwifery and other aseptic operations.
Model | Overall dimensions of the vehicle (mm) | Vehicle weight (kg) | Inner size (mm) | Extended box width (mm) | Maximum speed (km/h) |
Mobile General Surgery Unit | 11990*2500*3970 | 13500 | 9307*2365*2105 | 900 | 89 |
The mobile CT unit can be used for imaging diagnosis of diseases of various systems in the whole body, especially for lung examination during the epidemic. At the same time, it is easy to move and transport, reducing the risk of infection when going to the hospital for examination.
Model | Overall Dimensions of the Vehicle (mm) | Vehicle Weight (kg) | Suspension System | Cab Occupants | Maximum Speed (km/h) |
Mobile CT Examination Vehicle | 11985*2550*3980 | 30400 | air suspension | 3 | 89 |
The 5G mobile stroke unit is to integrate mobile CT(Mobile Computed Tomography,MCT) and related testing instruments on the ambulance. Under the 5G network, it forms a treatment unit that integrates neurological symptomology examination, CT diagnosis and intravenous thrombolysis treatment.
The 5G mobile stroke unit adopts mobile medical innovation technology, mainly including: small mobile CT, scanner, inspection and monitoring medical equipment with information transmission function, 5G network, consultation center, remote stroke treatment center and other mobile medical technology and auxiliary equipment.
Model | Overall Dimensions of the Vehicle (mm) | Vehicle Weight (kg) | Maximum Speed (km/h) | Seat (Person) | CT | Medical Cabin |
Emergency Stroke Vehicle | 5990*2300*2900 | 6050 | 120 | 7 | 16 rows of mobile CT | Lead protection – protection level meets the requirements of GBZ264- 2015 standard |
Detection of a wide range of diseases, extended coverage of remote areas, and quick results. It is a supplementary choice for fixed sampling and biological laboratories.
Model | Dimension | Max. Speed | Fuel Consumption | Vehicle Weight | Drive Mode | Rated Power |