The device operates as a small and reliable platform to perform in vitro release tests and permeation experiments. This device meets all parameters of USP <1724> which allows precise simulation of drug diffusion processes in creams gels and patches. The system includes automatic preheating along with covered dissolving cups and it provides synchronous dosing for precise reproducible outcomes. The system’s design logic manages to reduce turbulent conditions and stops bubbles from forming which leads to dependable experimental outcomes. The system can store an unlimited amount of data and implements validation requirements according to FDA 21 CFR Part 11 to deliver strict pharmaceutical quality evaluation.
Length ×Width× Height(Fully Raised):~ 63 cm × 56cm ×96 cm | Dissolution Vessel Number: 8 |
Setting Range: 20-250 rpm (RPM) | RPM Resolution: 0.01RPM |
Steady Speed Error: ≤±0.3RPM | Temp. Accuracy: ≤±0.2℃ |
Temp. Resolution: 0.01 ℃ | Level: < 0.5° |
Vessel Verticality: 90°±0.5° | Shaft Verticality: 90°±0.5° |
Centering Deviation: < ±2.0 mm | Depth Positioning Deviation: < ±1.0 mm |
Shaft Wobble: < ±1.0 mm | Basket Wobble: < ±1.0 mm |
The RT806 is structured as a small-sized Vertical Franz Diffusion Cell system that includes heating functionalities with a built-in stirrer module. The device comes with a portable layout that makes it easy to place in any location for convenient operation. The system delivers detailed temperature and speed management needed for reliable transdermal testing. The system meets the performance requirements outlined in USP<1724> for the simulation of in vitro release and permeation procedures. Bubbles are prevented through the filling point design which results in dependable experimental outcomes.
Length ×Width× Height(Fully Raised): 63 cm × 56cm ×96 cm | Dissolution Vessel Number: 8 |
Setting Range: 20-250 rpm (RPM) | RPM Resolution: 0.01RPM |
Steady Speed Error: ≤±0.3RPM | Temp. Accuracy: ≤±0.2℃ |
Temp. Resolution: 0.01 ℃ | Level: < 0.5° |
Vessel Verticality: 90°±0.5° | Shaft Verticality: 90°±0.5° |
Centering Deviation: < ±2.0 mm | Depth Positioning Deviation: < ±1.0 mm |
Shaft Wobble: < ±1.0 mm | Basket Wobble: < ±1.0 mm |
The RT700 Flow-through Cell Dissolution System operates as a precise evaluation instrument that examines sustained-release products along with suspensions and liposomal drugs. The system allows testing with open-loop and closed-loop sampling operations to suit diverse dissolution requirements. It operates with seven flow cells which support accurate analysis through dual flow rate testing functions. This system includes water bath heaters which are integrated with real-time temperature control systems for accurate environmental monitoring. The patented filtration method operates by reducing back pressure so samples can process optimally.
Length ×Width× Height: ~ 80 cm × 62 cm ×60 cm | Temperature resolution: 0.1 ℃ |
Number of channels: 7 | Temperature control error:<±0.2℃ |
Temperature control range: room temperature +5°C-50°C | Temperature difference between the cells: <±0.5℃ |
Both open-loop mode and closed-loop mode are available |
Length × Width × Height:~98cm× 63cm×55cm | Velocityresolution: 0.1mL/min |
The stirring working position:8 | Velocity error: <±5% |
Stirring speed error: ≤± 10% | Temperature control range: room temperature +5°C-50°C |
Velocity range: 1~40mL/min | Temperature probe error: ≤± 0.5 ℃ |
Temperature resolution: 0.1 ℃ |
Length × Width × Height:~75cm×63 cm×56 cm | Maximum sampling times: 45(closed-loop mode), unlimited(open-loop mode) |
Number of channels: 7 | Sampling volume error: ≤± 2% (closed-loop mode), ≤± 5% (open-loop mode) |
Test tube type:70 ml sample bottle,10 ml test tube, Liquid Phase Vial | Pump type: syringe pump |
Meet the requirements of FDA21 CFR Part 11 |
The RT806 is structured as a small-sized Vertical Franz Diffusion Cell system that includes heating functionalities with a built-in stirrer module. The device comes with a portable layout that makes it easy to place in any location for convenient operation. The system delivers detailed temperature and speed management needed for reliable transdermal testing. The system meets the performance requirements outlined in USP<1724> for the simulation of in vitro release and permeation procedures. Bubbles are prevented through the filling point design which results in dependable experimental outcomes.
Length ×Width× Height: ~ 80 cm × 62 cm ×60 cm | Length ×Width× Height: ~ 80 cm × 62 cm ×60 cm |
Number of channels: 7 | Number of channels: 7 |
Temperature resolution: 0.1 ℃ | Temperature resolution: 0.1 ℃ |
Length ×Width× Height: ~ 98cm × 63 cm ×55 cm | Length ×Width× Height: ~ 98cm × 63 cm ×55 cm |
Stirring speed error: ≤± 10% | Stirring speed error: ≤± 10% |
Velocity resolution: 0.1mL/min | Velocity resolution: 0.1mL/min |
Temperature probe error: ≤± 0.5 ℃ | Temperature probe error: ≤± 0.5 ℃ |
Length ×Width× Height: ~75cm × 63 cm ×56 cm | Length ×Width× Height: ~75cm × 63 cm ×56 cm |
Test tube type: 70 ml sample bottle, 10 ml test tube, liquid phase vial | Test tube type: 70 ml sample bottle, 10 ml test tube, liquid phase vial |
Sampling volume error: ≤± 2% (closed-loop mode), ≤± 5% (open-loop mode ) | Sampling volume error: ≤± 2% (closed-loop mode), ≤± 5% (open-loop mode ) |
*Meet the requirements of FDA21 CFR Part 11 |
The RT3 Reciprocating Cylinder operates as an advanced dissolution testing equipment that duplicates in vivo mechanical stress conditions by offering exact control of bicurious motions. The device integrates an automatic vessel cover which reduces evaporation losses while offering single-piece water baths that promote efficient heating. Users can modify the reciprocating stroke together with the rate and immersion time through flexible settings accessible by the system. A precise filtration device with high accuracy filters drug matter to generate proper test results. The device operates through an 8.4-inch touchscreen interface that makes operation easy by meeting all requirements from FDA 21 CFR Part 11.
Length ×Width× Height(Fully Raised): 80cm × 63cm ×100 cm | Dissolution Vessel Row Number: 7 tubes ×6 Rows(300mL Stand Vessel) |
Dissolution System Level: ≤ 0.3° | Shaft Verticality: ≤ 90°± 0.5° |
Temperature Control Range: Ambient Temperature ~ 50℃ | Temp. Resolution: 0.1 ℃ |
Temp. Accuracy: ≤ ± 0.2℃ | Vessels’ Temp. Difference: ≤ ± 0.5℃ |
Adjustable Range of Reciprocating Stroke: 2 ~ 10 cm | Error of Reciprocating Stroke: ≤ ± 0.1 cm |
Adjustable Range of Reciprocating Rate: 4 ~ 60 DPM | Error of Reciprocating Rate: ≤ ±5% |
Maximum Running Time: 600 (Hours) |
|
Meet the requirements of FDA21 CFR Part 11 |
Manufactured for precise dissolution tests with automated samples and filtering mechanisms is the RT3-AT Reciprocating Cylinder Dissolution System. This unit has an integrated coaxial bracket that enables fast mount replacements for holders alongside automatic vessel lids that protect against evaporation over time. The design incorporates a single-piece water bath which provides uniform heating properties and full drainage. The equipment operates with a high-precision sampling pump as well as an advanced Teflon pipeline system which prevents sample adsorption and maintains accurate results. Users can adjust the parameters for reciprocating stroke position alongside rate immersion duration and drainage duration according to FDA 21 CFR Part 11 standards.
Length ×Width× Height(Fully Raised): 80cm × 63cm ×100 cm | Dissolution Vessel Row Number: 7 tubes×6 Rows (300mL Stand Vessel) |
Dissolution System Level: ≤ 0.3° | Shaft Verticality: ≤ 90°± 0.5° |
Temperature Control Range: Room Temperature ~ 50℃ | Temp. Resolution: 0.1 ℃ |
Temp. Accuracy: ≤ ± 0.2℃ | Vessels Temp. Difference: ≤ ± 0.5℃ |
Adjustable Range of Reciprocating Stroke: 2 ~ 10 cm | Error of Reciprocating Stroke: ≤ ± 0.1 cm |
Adjustable Range of Reciprocating Rate: 4 ~ 60 DPM | Error of Reciprocating Rate: ≤ ±5% |
Maximum Running Time: 600 (Hours) |
Maximum Settable Sampling Number: 30 Times | Maximum Sampling Volume: 1~10ml |
Sampling Precision: ≤±1% | Sample Collector: Suitable for 10ml Test Tube or HPLC Vial |
Meeting FDA21 CFR Part 11 |
The RT612 Dissolution Tester serves as a machine consisting of single or dual control methods to perform accurate 12-position dissolution testing. The system fulfills the requirements of ChP (0931) USP (711/724) and EP (2.9.3/4) for pharmaceutical quality control assessments. The system performs automated drug delivery and operates with real-time controls of speed and temperature and unlimited storage capacity. The tester boasts an advanced structure that both lessens fluid turbulence and improves user-friendliness.
Length ×Width× Height(Fully Raised):92cm ×56cm ×96cm | Dissolution Vessel Number: 12 |
Setting Range: 20-250 rpm (RPM) | RPM Resolution: 0.01RPM |
Steady Speed Error: ≤±0.3RPM | Temp. Accuracy: ≤±0.2℃ |
Temp. Resolution: 0.01 ℃ | Level: < 0.5° |
Vessel Verticality: 90°±0.5° | Shaft Verticality: 90°±0.5° |
Centering Deviation: < ±2.0 mm | Depth Positioning Deviation: < ±1.0 mm |
Shaft Wobble: < ±1.0 mm | Basket Wobble: < ±1.0 mm |
Meeting FDA21 CFR Part 11 |
RT612-ST Automated Dissolution Tester serves as a precise pharmaceutical dissolution testing system that operates through 12 different positions. The device operates with automatic dosage functions together with real-time instrumentation of speed and temperature levels as well as adjustable sampling capabilities. The built-in co-axial paddle basket design enables method changes through adjustments free of height modifications.
Length ×Width× Height(Fully Raised):~ 92 cm × 56cm ×96 cm | Dissolution Vessel Number: 12 |
Setting Range:20-250 rpm (RPM) | RPM Resolution: 0.01RPM |
Steady Speed Error:≤±0.3RPM | Temp. Accuracy: ≤±0.2℃ |
Temp. Resolution: 0.01 ℃ | Level: < 0.5° |
Vessel Verticality: 90°±0.5° | Shaft Verticality: 90°±0.5° |
Centering Deviation: < ±2.0 mm | Depth Positioning Deviation: < ±1.0 mm |
Shaft Wobble: < ±1.0 mm | Basket Wobble: < ±1.0 mm |
Length ×Width× Height: 40 cm ×70cm ×70 cm | Maximum Settable Sample Number: 20 |
Sampling Range: 1 ~ 20ml | Minimum Sampling Interval: First Sampling Point: 3 minutes |
Maximum Working Time: 720 hours | Sampling Precision: ≤±1% |
Meeting FDA21 CFR Part 11 |
The RT630-HT02 Drug Dissolution Testing Equipment operates as a precise dual-module automatic sampling system which satisfies all requirements from Chp (0931), USP (711/724), and EP (2.9.3/4). The device runs two autonomous dissolution tests simultaneously which supports distinct devices and speeds and solvents and sampling points for optimized testing results
Length ×Width× Height (Fully Raised): 95cm × 65cm ×82 cm | Dissolution Vessel Number: 14 (12 dissolution levels+2 thermostatic refill levels) |
Setting Range: 20-250 rpm (RPM) | RPM Resolution: 0.01RPM |
Steady Speed Error: ≤±0.3RPM | Temp. Accuracy: ≤±0.2℃ |
Temp. Resolution: 0.01 ℃ | Level: < 0.5° |
Vessel Verticality: 90°±0.5° | Shaft Verticality: 90°±0.5° |
Centering Deviation: < ±2.0 mm | Depth Positioning Deviation: < ±1.0 mm |
Shaft Wobble: < ±1.0 mm | Basket Wobble: < ±1.0 mm |
Length ×Width× Height: 40 cm × 70cm ×50 cm | Maximum Settable Sample Number: 36 |
Sampling Range: 1 ~ 20ml | Minimum Sampling Interval: 4 minutes |
Maximum Working Time: 720 hours | Sampling Precision: ≤±1% |
Meeting FDA21 CFR Part 11 |
The RT630-HT02 Dissolution Quality Control Tester is a 14-positions, dual-module, auto-sampling dissolution system. It fully meets the testing requirements in Chp (0931), USP (711/724), EP (2.9.3/4). Supports two independent dissolution tests at the same time and storage and online automatic replacement of secondary filters. Meets the needs of high-precision and high-efficiency dissolution testing.
Length ×Width× Height (Fully Raised): ~95cm × 65cm ×82 cm | Dissolution Vessel Number: 14 (12 dissolution levels+2 thermostatic refill levels) |
Setting Range: 20-250 rpm (RPM) | RPM Resolution: 0.01 RPM |
Steady Speed Error: ≤±0.3 RPM | Temp. Accuracy: ≤±0.2℃ |
Temp. Resolution: 0.01 ℃ | Level: < 0.5° |
Vessel Verticality: 90°±0.5° | Shaft Verticality: 90°±0.5° |
Centering Deviation: < ±2.0 mm | Depth Positioning Deviation: < ±1.0 mm |
Shaft Wobble: < ±1.0 mm | Basket Wobble: < ±1.0 mm |
Length ×Width× Height: 32 cm × 65cm ×61 cm(single-unit) | Maximum Settable Sample Number: 36 |
Sampling Range: 1 ~ 20ml | Minimum Sampling Interval: 4 minutes |
Maximum Working Time: 720 hours | Sampling Precision: ≤±1% |
The RT600-UV Online Drug Dissolution Tester design along with the performance of RT7 Flow-Through Cell Dissolution System fulfills requirements stated in Chinese Pharmacopoeia 2020’s sixth dissolution method and USP dissolution apparatus 4 and European Pharmacopoeia dissolution apparatus 4. One RT7 Flow-Through Cell Dissolution System supports both open-loop method and closed-loop method operation through its automatic sampling work station without equipment removal which enables testing of different sample types following various flow-through cell methods.
Length ×Width× Height: ~ 80 cm × 62 cm ×60 cm | Length ×Width× Height: ~ 80 cm × 62 cm ×60 cm |
Number of channels: 7 | Number of channels: 7 |
Temperature resolution: 0.1 ℃ | Temperature resolution: 0.1 ℃ |
Length ×Width× Height: ~ 98cm × 63 cm ×55 cm | Length ×Width× Height: ~ 98cm × 63 cm ×55 cm |
Stirring speed error: ≤± 10% | Stirring speed error: ≤± 10% |
Velocity resolution: 0.1mL/min | Velocity resolution: 0.1mL/min |
Temperature probe error: ≤± 0.5 ℃ | Temperature probe error: ≤± 0.5 ℃ |
Length ×Width× Height: ~75cm × 63 cm ×56 cm | Length ×Width× Height: ~75cm × 63 cm ×56 cm |
Test tube type: 70 ml sample bottle, 10 ml test tube, liquid phase vial | Test tube type: 70 ml sample bottle, 10 ml test tube, liquid phase vial |
Sampling volume error: ≤± 2% (closed-loop mode), ≤± 5% (open-loop mode ) | Sampling volume error: ≤± 2% (closed-loop mode), ≤± 5% (open-loop mode ) |
*Meet the requirements of FDA21 CFR Part 11 |
The T8 Drug Release Testing Equipment serves as a laboratory tool for manual and single-drive operations to run drug release tests on eight different samples according to Chp (0931), USP (711/724), and EP (2.9.3/4) standards. This testing equipment supports all essential standards of Chp (0931), USP (711/724), and EP (2.9.3/4) together with unlimited storage for methods and experiments. Its small size along with light weight enables this instrument to fit in restricted laboratory areas.
Length ×Width× Height (Fully Raised): 65cm × 56cm ×100cm | Dissolution Vessel Number: 8 |
Setting Range: 20-250 rpm (RPM) | RPM Resolution: 0.01RPM |
Steady Speed Error: ≤±1 RPM | Temperature adjustment range: room temperature -50 ℃ |
Temp. Accuracy: ≤±0.5℃ | Temp. Resolution: 0.01 ℃ |
Level: < 0.5° | Vessel Verticality: 90°±0.5° |
Shaft Verticality: 90°±0.5° | Centering Deviation: < ±2.0 mm |
Depth Positioning Deviation: < ±1.0 mm | Shaft Wobble: < ±1.0 mm |
Basket Wobble: < ±1.0 mm |
Comes with built-in operation video guidance to improve the efficiency of user training. |
The RT500 Degassing and Media Preparation System functions as a high-tech unit that warms dissolution media to perform degassing while dispensing large volumes of up to 25L without interrupting the operation. This system provides accurate liquid volume control along with efficient heating features as well as it fulfills USP media degassing standards. User-friendly control features in the system lead to faster preparation times and better workflow effectiveness. Through its flow control system, the device provides real-time monitoring of liquid entry and discharge operations.
Length ×Width× Height: 60 cm × 55 cm ×79 cm | Temp. Control Rang: Room Temp. ~ 45℃ |
Temp. Resolution: 0.1 ℃ | Measure Range of System Pressure: 0.02~ 0.09 Mpa |
Pressure Resolution:0.01 Mpa | Degassing Volume: 2 ~ 25L |
Degassing Time: 8 ~ 60min | Degassing Temp.: 2 ~ 45℃ |
Vacuum Degree: 0.02~ 0.04 Mpa |
RT510 Automated Media Preparation System functions as a lightweight high-efficiency solvent-handling system that operates with most dissolution meters. The system combines heating functions and degassing and dispensing functions into one process so operators no longer need to perform manual steps to complete media preparation and save time.It enables fast and efficient media preparation through its ability to degas unlimited volumes at a rate exceeding 900 mL per minute. The system performs accurate control to produce consistent solvents that have oxygen levels under 3 ppm. The platform makes it easy for laboratory teams to operate efficiently.
Length ×Width× Height: 58 cm × 28 cm ×42 cm | Temp. Control Rang: Room Temp. ~ 50℃ |
Temp. Control Precision: Error: ≤ ±1℃ | Temp. Resolution: 0.1 ℃ |
Volume Range of Medium Distribution: 100 ~ 1000 mL | Volume Precision of Medium Distribution: Error ≤ 1% |
Control Range of Vacuum Degree: 80~90 kPa | Control Precision of Vacuum Degree: Error ≤ 1% |
Resolution of Vacuum Degree: 0.1 kPa | Degassing Rate: ≥ 900 mL/min |
Degassing Effect: Oxygen ≤ 3ppm |
The RT200 Dissolution Mechanical Calibration Tool Kit functions as a specialized validity check system for RT6 series dissolution testers. The tool kit contains measurement modules that obtained certification from metrology organizations to enable compliance with calibration standards. This kit allows for precise measurement of dissolution meter level as well as verticality and wobbling while assessing coaxiality and height rotational speed and temperature uniformity. The testing device combines reliable design with components that confirm that dissolution testers satisfy regulatory mechanical standards. Laboratory technicians find this device excellent because of its portable dimensions and convenient format.
RT260 Dissolution Mechanical Calibration Workstation serves as a precise testing system for RT6 series dissolution testers. The workplace generates test reports automatically after receiving real-time calibration data through wireless transmission. The automated system eliminates the need for manual recording thus guaranteeing data accuracy and maintaining adherence to both standards of data integrity