Metrological parameters
Maximum capacity [Max] | 1.5 kg – 300kg |
Minimum load | 10g – 2kg |
Readability [d] | 0.5g -100g |
Tare range | -1.5 kg – -300kg |
OIML Class Physical parameters | III |
Display | 5” graphic colour |
Weighing pan dimensions | 300×300 mm – 400×500mm |
Net weight | 12.3kg -18.1kg |
Gross weight | 13.3kg – 20.3kg |
Protection class | IP 65 construction, IP 66/68 indicator |
ATEX Certification | II 2G Ex ib IIB T4 Gb |
IECEx Certification | Ex ic IIB T4 Gc |
Indicator | PUE HX5.EX-1 |
Weighing pan material Communication interface | stainless steel AISI304 |
Communication interface Electrical parameters | 2×RS232, RS485 |
Power supply | 100 — 240 V AC 50 / 60 Hz |
Power consumption max. Environmental conditions | 15 W |
Operating temperature | -10 — +40 °C |
Relative humidity Construction | 10% — 85% RH no condensation |
Construction | mild steel St3S |
Metrological parameters
Maximum capacity [Max] | 1.5 kg – 300kg |
Minimum load | 10g-2kg |
Readability [d] | 0.5g -100g |
Tare range | -1.5 kg – -300kg |
OIML Class Physical parameters | III |
Display | 5” graphic colour |
Weighing pan dimensions | 300×300 mm – 400×500mm |
Net weight | 12.3kg -18.1kg |
Gross weight | 13.3kg – 20.3kg |
Protection class | IP 65 construction, IP 66/68 indicator |
ATEX Certification | II 2G Ex ib IIB T4 Gb |
IECEx Certification | Ex ic IIB T4 Gc |
Indicator | PUE HX5.EX-1 |
Weighing pan material Communication interface | stainless steel AISI304 |
Communication interface Electrical parameters | 2×RS232, RS485 |
Power supply | 100 — 240 V AC 50 / 60 Hz |
Power consumption max. Environmental conditions | 15 W |
Operating temperature | -10 — +40 °C |
Relative humidity Construction | 10% — 85% RH no condensation |
Construction | mild steel St3S |
Maximum capacity [Max] | 60kg -6000kg |
Minimum load | 400g – 40kg |
Readability [d] | 20g – 2000g |
Tare range | -60kg – -6000kg |
Display | 5” graphic colour
|
Weighing pan dimensions | 1000×1000mm -1500×2000mm |
Net weight | 87.8 kg – 237.8kg |
Gross weight | 88kg – 238kg |
Protection class | IP 65 construction, IP 66/68 indicator
|
ATEX Certification | II 2G Ex ib IIB T4 Gb
|
IECEx Certification | Ex ib IIB T4 Gb
|
Indicator | PUE HX5.EX-1
|
Communication interface | 2×RS232, RS485
|
Power supply | 100 — 240 V AC 50 / 60 Hz
|
Power consumption max. | 15 W
|
Operating temperature | -10 — +40 °C |
Relative humidity | 10% — 85% RH no condensation
|
Construction | mild steel St3S
|
Maximum capacity [Max] | 60kg – 6000kg |
Minimum load | 400g – 40kg |
Readability [d] | 20g – 2000g |
Tare range | -60kg – -6000kg |
Display | 5” graphic colour
|
Weighing pan dimensions | 800×800mm – 1500×2000mm |
Net weight | 62.8kg – 287.8kg |
Gross weight | 63kg -288kg |
Protection class | IP 67 construction, IP 66/68 indicator
|
ATEX Certification | II 2G Ex ib IIB T4 Gb
|
IECEx Certification | Ex ib IIB T4 Gb
|
Indicator | PUE HX5.EX-1
|
Communication interface | 2×RS232, RS485
|
Power supply | 100 — 240 V AC 50 / 60 Hz
|
Power consumption max. | 15 W
|
Operating temperature | -10 — +40 °C |
Relative humidity | 10% — 85% RH no condensation
|
Construction | Stal stainless steel AISI304
|
Maximum capacity [Max] | 600kg – 3000kg |
Minimum load | 4kg – 20kg |
Readability [d] | 200g – 1000g |
Tare range | -600kg – (-3000)kg |
OIML Class | III
|
Display | 5” graphic colour
|
Weighing pan dimensions | 840×1200 mm |
Packaging dimensions | 1400×900×430 mm |
Net weight | 49.8 kg |
Gross weight | 50 kg |
Protection class | IP 65 construction, IP 66/68 indicator
|
ATEX Certification | II 2G Ex ib IIB T4 Gb
|
IECEx Certification | Ex ib IIB T4 Gb
|
Indicator | PUE HX5.EX-1
|
Communication interface | 2×RS232, RS485
|
Power supply | 100 — 240 V AC 50 / 60 Hz
|
Power consumption max. | 15 W
|
Operating temperature | -10 — +40 °C |
Relative humidity | 10% — 85% RH no condensation
|
Construction | mild steel St3S
|
Maximum capacity [Max] | 3kg – 150kg |
Minimum load | 20g – 1kg |
Readability [d] | 1g – 50g |
Tare range | -3kg – (-150)kg |
OIML Class | III
|
Display | 5” graphic colour
|
Weighing pan dimensions | 250×300mm – 500×500mm |
Net weight | 14.3kg – 24.8kg |
Gross weight | 16kg – 28.5kg |
Protection class | IP 68 construction, IP 66/68 indicator
|
ATEX Certification | II 2G Ex ib IIB T4 Gb
|
IECEx Certification | Ex ib IIB T4 Gb
|
Indicator | PUE HX5.EX-1
|
Weighing pan material | stainless steel AISI316
|
Communication interface | 2×RS232, RS485
|
Power supply | 100 — 240 V AC 50 / 60 Hz
|
Power consumption max. | 15 W
|
Operating temperature | -10 — +40 °C |
Relative humidity | 10% — 85% RH no condensation
|
Construction | Stal stainless steel AISI316
|
Maximum capacity [Max] | 60kg – 6000kg |
Minimum load | 400g – 40kg |
Readability [d] | 20g – 2000g |
Tare range | -60kg – (-6000)kg |
Display | 5” graphic colour
|
Weighing pan dimensions | 800×800mm – 1500×2000mm |
Net weight | 62.8kg – 352.8kg |
Gross weight | 63kg – 353kg |
Protection class | IP 68 construction, IP 66/68 indicator
|
ATEX Certification | II 2G Ex ib IIB T4 Gb
|
IECEx Certification | Ex ib IIB T4 Gb
|
Indicator | PUE HX5.EX-1
|
Communication interface | 2×RS232, RS485
|
Power supply | 100 — 240 V AC 50 / 60 Hz
|
Power consumption max. | 15 W
|
Operating temperature | -10 — +40 °C |
Relative humidity | 10% — 85% RH no condensation
|
Construction | Stal stainless steel AISI304
|
Maximum capacity [Max] | 60kg – 1500kg |
Minimum load | 400g – 10kg |
Readability [d] | 20g – 500g |
Tare range | -60kg – (-1500)kg |
OIML Class | III
|
Display | 5” graphic colour
|
Weighing pan dimensions | 840×860mm – 1500×1500mm |
Device dimensions | 1710×1160×76mm – 2450×1820×77mm |
Net weight | 72.8kg – 192.8kg |
Gross weight | 73kg – 193kg |
Protection class | IP 67 construction, IP 66/68 indicator
|
ATEX Certification | II 2G Ex ib IIB T4 Gb
|
IECEx Certification | Ex ib IIB T4 Gb
|
Indicator | PUE HX5.EX-1
|
Communication interface | 2×RS232, RS485
|
Power supply | 100 — 240 V AC 50 / 60 Hz
|
Power consumption max. | 15 W
|
Operating temperature | -10 — +40 °C |
Relative humidity | 10% — 85% RH no condensation
|
Construction | Stal stainless steel AISI304
|
Maximum capacity [Max] | 600kg – 3000kg |
Minimum load | 4kg – 20kg |
Readability [d] | 200g – 1000g |
Tare range | -600kg – (-3000)kg |
OIML Class | III
|
Display | 5” graphic colour
|
Weighing pan dimensions | 860×1200mm |
Packaging dimensions | 1400×900×430mm |
Net weight | 49.8kg |
Gross weight | 50kg |
Protection class | IP 68 construction, IP 66/68 indicator
|
ATEX Certification | II 2G Ex ib IIB T4 Gb
|
IECEx Certification | Ex ib IIB T4 Gb
|
Indicator | PUE HX5.EX-1
|
Communication interface | 2×RS232, RS485
|
Power supply | 100 — 240 V AC 50 / 60 Hz
|
Power consumption max. | 15 W
|
Operating temperature | -10 — +40 °C |
Relative humidity | 10% — 85% RH no condensation
|
Construction | Stal stainless steel AISI304
|
Maximum capacity [Max] | 600kg – 6000kg |
Minimum load | 4kg – 40kg |
Readability [d] | 200g – 2000g |
Tare range | -600kg – (-6000)kg |
OIML Class | III
|
Display | 5” graphic colour
|
Weighing pan dimensions | 2 pcs 1.2 m – 2 pcs 2.5 m |
Net weight | 43.8kg – 139.8kg |
Gross weight | 44kg – 140kg |
Protection class | IP 68 construction, IP 66/68 indicator
|
ATEX Certification | II 2G Ex ib IIB T4 Gb
|
IECEx Certification | Ex ib IIB T4 Gb
|
Indicator | PUE HX5.EX-1
|
Communication interface | 2×RS232, RS485
|
Power supply | 100 — 240 V AC 50 / 60 Hz
|
Power consumption max. | 15 W
|
Operating temperature | -10 — +40 °C |
Relative humidity | 10% — 85% RH no condensation
|
Construction | Stal stainless steel AISI304
|
The series of HRP professional high resolution platforms suits every single branch of industry requiring high accuracy, precision and repeatability of measurement in challenging industrial environment. Platforms of HRP series are a perfect partner of yours.
Automatic adjustment performed by means of an internal adjustment weight is a warranty for a remarkably effective operation and repeatability of indications. You save your time and avoid the inconvenience of manual operation.
The platform design complies with 2014/34/UE directive and IECEx certification system. Depending on the construction, the device can be used in environment filled with explosive gases and dusts, classified as zones: 2 and 22.
The platform is equipped with an intrinsically safe RS 485 communication interface enabling connection of the platform with a PUE HX5.EX terminal.
HRP can be connected to the mains only via an intrinsically safe power supply, PM02.EX-1 -2 or PM02.EX-2-2.\
Maximum capacity [Max] | 16kg – 2000 kg |
Minimum load | 5g – 200kg |
Preload range | 4kg – 20g |
Readability [d] | 0.1g – 20g |
Tare range | -16kg – (-2000)kg |
Repeatability | 0.1g – 30g |
Linearity | ±0.1g – ±60g |
Stabilization time | 2s – |
Adjustment | internal (automatic) |
Protection class | IP 66/67 |
ATEX Certification | ll 3G Ex ic IIC T4 Gc |
IECEx Certification | Ex ic IIC T4 Gc |
Weighing pan material | stainless steel AISI304 |
Communication interface | RS485 |
Power supply | 100 — 240 V AC 50 / 60 Hz |
Operating temperature | +10 — +40 °C |
Relative humidity | 15% — 80% |
Housing | stainless steel |
Weighing pan dimensions | 360×280 mm |
Device dimensions | 360×313×170 mm |
Net weight | 18.7 kg |
PUE HX5.EX terminal is a constructional component of industrial multifunctional load cell scales. It is the most modern RADWAG solution to be used in areas endangered with explosive atmosphere. The HX5.EX is compliant with ATEX directive regulations. The terminal is intended for operation in environment filled with explosive gases and dust, and can be placed in zones: 1/21 and 2/22.
Standard version of the terminal is equipped with 2 serial intrinsically safe RS232 communication interfaces, and with one intrinsically safe RS485 interface. They facilitate communication with equipment predetermined for use in hazardous areas. Possibility to add digital inputs/outputs expands the range of instruments compatible with the terminal by robotic elements compliant with ATEX directive. For more demanding customers, RADWAG has developed IM01.EX module, installed in the safe area, which extends the available connector range by Ethernet, USB, 4-20mA/0-10V analog outputs, Profibus DP and additional digital inputs/outputs. This enables communication between the terminal and external devices such as barcode scanners, printers, external displays, control buttons, light signalling towers, other controlling/signalling devices, systems for automatic process control and superior IT systems.
Models
There are 4 different models:
Mechanical Design
The housing, made of AISI 304 stainless steel, ensures high ingress protection, IP66 / IP68 (up to 1.5 m immersion). The terminal features 5″ colour LCD, covered with polycarbonate protecting it against shocks, and a membrane keypad. Ease of operation, clear menu and intuitive information arrangement on the display guarantee comfort of operation. Hermetic intrinsically safe interface connectors are located on the back side of the housing. Stable bracket enables mounting the terminal either on a flat horizontal surface or on the wall. The device tilt can be easily adjusted.
Power Supply
The PUE HX5.EX terminal can be connected to the mains only with a certified intrinsically safe power supply, manufactured by RADWAG:
IM01.EX Communication Module
The terminal’s interface range can be expanded using IM01.EX communication module, connected to the terminal via an intrinsically safe RS485 interface, placed outside the hazardous area.
Models:
Multifunctional Software
Terminal software facilitates processes such as weighing, parts counting, dosing, and percent weighing. Terminal’s information system is based on databases (users, products, weighings, packaging, formulations, customers) and ALIBI memory which guarantees stored data safety. The interfaces enable communication between the terminal and the accessories intended for operation in the hazardous and non-hazardous areas. Accessories: barcode scanners, printers, external displays, control buttons, light signalling towers and other controlling/signalling devices. The terminal can communicate with systems for automatic process control and superior IT systems.
Maximum quantity of verification units | 6000 e
|
OIML Class | III
|
Maximum quantity of divisions from converter | 100 000
|
Maximum increase of signal | 19.5 mV
|
Minimum volatge per verification unit | 0.4 µV
|
Minimum load cell impedance | 80 Ω
|
Maximum load cell impedance | 1200 Ω
|
Connection of load cells | 4 or 6 wires + shield
|
Display | 5” graphic colour
|
Device dimensions | 329×231×120 mm |
Packaging dimensions | 640×310×220 mm |
Net weight | 7.8 kg |
Gross weight | 8.8 kg |
Protection class | IP 66 / IP 68
|
ATEX Certification | II 2G Ex ib IIC T4 Gb (gases)
|
Working in zones | 1, 2 (gases); 21, 22 (dusts)
|
Communication interface | 2×RS232, RS485
|
Operating temperature | -10 — +40 °C |
Housing | stainless steel
|
Protection class | IP66 / IP68
|
ATEX Certification | II (2)G [Ex ib Gb] IIC
|
Working in zones | –
|
Power supply | 100 — 240 V AC 50 / 60 Hz
|
Power consumption max. | 15 W
|
Operating temperature | -20 — +40 °C |
Storage temperature | -20 — +60 °C |
Relative humidity | 10% — 85% RH no condensation
|
Housing | stainless steel
|
Device dimensions | 216×174×64 mm |
With use of IM01.EX communication module it is possible to expand communication interfaces range of the HX5.EX indicator. The module is installed outside the hazardous area, and connected to the indicator using intrinsically safe interface.
IM01.EX allows to establish communication between the scale and various accessories, e.g. barcode scanners, printers, displays, control buttons, light signalling towers, buzzers and other controlling/signalling devices. It also enables connection with systems of automatic adjustment and control of industrial processes, and with superior IT systems.
IM01.EX-1 interfaces:
Protection class | IP 66 / IP 68 (1.5m)
|
ATEX Certification | II (2)G [Ex ib] IIC Gb
|
Inputs/Outputs | 4IN / 4OUT
|
USB | ×1
|
Ethernet | ×1
|
RS232 | ×2
|
Power supply | 100 — 240 V AC 50 / 60 Hz
|
Power consumption max. | 10 W
|
Operating temperature | -10 — +40 °C |
Storage temperature | -20 — +60 °C |
Relative humidity | 10% — 85% RH no condensation
|
Housing | aluminum
|
Device dimensions | 222×146×81 mm |
Net weight | 1.9 kg |
Gross weight | 2.5 kg |