Maximum capacity [Max] | 21g |
Minimum load | 100µg |
Readability [d] | 1µg |
Tare range | -21g |
Verification scale interval [e] | 1mg |
Standard repeatability [5% Max] | 1µg |
Standard repeatability [Max] | 3µg |
Permissible repeatability [5% Max] | 1.6µg |
Permissible repeatability [Max] | 4µg |
Linearity | ±7µg |
Eccentric load deviation | 7µg |
Stabilization time | max 10 s |
Adjustment | internal (automatic)
|
OIML Class | I
|
Standard minimum weight (USP) | 2mg |
Standard minimum weight (U=1%, k=2) | 0.2mg |
Protection class | IP 43
|
Levelling system | automatic – Reflex Level System
|
Display | 5.7” resistive colour touchscreen
|
Weighing chamber dimensions | ø90×90mm |
Weighing pan dimensions | ø26mm |
Packaging dimensions | 660×660×455mm |
Net weight | 9.1kg |
Gross weight | 16.6kg |
Communication interface | 2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi®
|
Power supply | 100 — 240 V AC 50 / 60 Hz
|
Power consumption max. | 10 W
|
Operating temperature | +10 — +40 °C |
Operating temperature change rate | ±0.3°C/1h (±1°C/8h)
|
Relative humidity change rate | ±1%/h (±4%/8h)
|
The MYA 21.4Y.P microbalance is a professional-class device for the most demanding applications that guarantees the highest quality, precision and reliability. It is equipped with an adapter enabling calibration and/or verification of piston pipettes by means of gravimetric method.
Use of the pipette calibration adapter reduces maximum capacity of the balance by the mass of the weighing vessel.
Faster measurement with the new CPU
4Y balances feature Dual Core 2 x 1 GHz processor which delivers noticeable performance improvements including faster operation and shorter stabilization time retaining high repeatability values.
16 GB RAM – more data management possibilities
16 GB RAM offers possibility of recording data in a form of complex reports. Time and statistic data diagrams on series of weighments are another useful option.
The best possible repeatability and USP regulations conformity
The best weighing accuracy and repeatability – with sd ≤ 1d combined with USP regulations conformity (Section 41 and 1251) make 4Y balances a new standard for mass measurement quality.
Ergonomics and safety
Wireless communication between balance terminal and a weighing unit make it possible to comfortably operate 4Y series balances in laminar air flow cabinets and fume cupboards.
Remote control operation
Wireless Connection module offers wireless transfer of data recorded by 4Y balance to any portable device powered by iOS or Android systems using special applications intended for data management.
Data safety
Every single 4Y balance features ALIBI memory designed to provide protection and automatic recording of your measurements. Options such as data preview, copying and archiving are also
available to users.
Filter weighing option
This innovative solution enables the user to easily swap the weighing chamber with the chamber for filter weighing, which considerably expands the MYA 4Y microbalance functionality. The filter weighing chamber is characterized by high ingress protection. Large open-work weighing pan allows precise weighing of filters of various dimensions (max ø100). It is made of stainless steel which makes the chamber resistant to chemicals, colour change and scratches. The additional chamber does not come standard with the MYA 4Y microbalance.
Maximum capacity [Max] | 21g |
Minimum load | 100µg |
Readability [d] | 1µg |
Tare range | -21g |
Verification scale interval [e] | 1mg |
Standard repeatability [5% Max] | 1µg |
Standard repeatability [Max] | 3µg |
Permissible repeatability [5% Max] | 1.6µg |
Permissible repeatability [Max] | 4µg |
Linearity | ±7µg |
Eccentric load deviation | 7µg |
Stabilization time | max 10 s |
Adjustment | internal (automatic)
|
OIML Class | I
|
Standard minimum weight (USP) | 2mg |
Standard minimum weight (U=1%, k=2) | 0.2mg |
Protection class | IP 43
|
Levelling system | semi-automatic – LevelSENSING
|
Display | 5.7” resistive colour touchscreen
|
Weighing chamber dimensions | ø90×90mm |
Weighing pan dimensions | ø26mm |
Packaging dimensions | 660×660×455mm |
Net weight | 9.1kg |
Gross weight | 16.6kg |
Communication interface | 2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi®
|
Power supply | 100 — 240 V AC 50 / 60 Hz
|
Power consumption max. | 10 W
|
Operating temperature | +10 — +40 °C |
Operating temperature change rate | ±0.3°C/1h (±1°C/8h)
|
Relative humidity change rate | ±1%/h (±4%/8h)
|
Maximum capacity [Max] | 6 / 21g – 53g |
Minimum load | 0.1mg – 0.5mg |
Readability [d] | 1 / 2µg – 1µg |
Tare range | -21g – (-53)g |
Verification scale interval [e] | 1mg – 2.2µg |
Standard repeatability [5% Max] | 1.3µg – 6µg |
Standard repeatability [Max] | 3.5µg – 3.4µg |
Permissible repeatability [5% Max] | 2µg – 8µg |
Permissible repeatability [Max] | 5µg |
Linearity | ±9µg – ±20µg |
Eccentric load deviation | 15µg – 20µg |
Stabilization time | ~ 3.5s |
Adjustment | internal (automatic)
|
OIML Class | I
|
Standard minimum weight (USP) | 2.6mg – 4.4mg |
Standard minimum weight (U=1%, k=2) | 0.26mg – 0.44mg |
Protection class | IP 43
|
Levelling system | automatic – Reflex Level System
|
Display | 5.7” resistive colour touchscreen
|
Weighing chamber dimensions | 199×170×217mm |
Weighing pan dimensions | ø26mm |
Packaging dimensions | 720×385×485mm |
Net weight | 14.5kg |
Gross weight | 18.9kg |
Communication interface | 2×RS232, 2×USB-A, Ethernet, 4 IN / 4 OUT (digital), Wi-Fi®
|
Power supply | 100 — 240 V AC 50 / 60 Hz
|
Power consumption max. | 10 W
|
Operating temperature | +10 — +40 °C |
Relative humidity | 20% — 80%
|
Selected volume1 of apparatus under test V | Resolution mg | Repeatability and linearity mg | Recommended balance | |||||
1 µl ≤ V ≤ 10 µl | 0.001 | 0.002 | MYA 21.4Y PLUS MYA 21.4Y | XA 6/21.4Y.M.A PLUS XA 6/21.4Y.M PLUS | ||||
10 µl < V ≤ 100 µl | 0.01 | 0.02 | XA 82/220.4Y.A PLUS XA 82/220.4Y PLUS | XA 120/250.4Y.A PLUS XA 120/250.4Y PLUS | ||||
100 µl < V ≤ 1000 µl | 0.1 | 0.2 | ||||||
1 ml < V ≤ 10 ml | 0.1 | 0.2 | ||||||
Adapter for pipette calibration | MY 11 | XA 11 | XA 17 | XA 100 | XA 17 | XA 100 | ||
Maximum vessel capacity | 11 ml | 11 ml | 17 ml | 100 ml | 17 ml | 100 ml | ||
Weighing vessel mass | ~10 g | ~10 g | ~11 g | ~65 g | ~11 g | ~65 g |
Application:
Calibration of automatic pipettes:
Unit contents:
Physical parameters
Length | 1350mm – 1100mm |
Width | 750mm |
Height | 1100 mm |
R-PIPETTES PC software is a RADWAG proprietary solution for determination of errors of pipette volume measurement (batchers) in accordance with the standard ISO 8655. The software supports calibration of fixed volume pipettes (single channel) and adjustable volume pipettes (1, 8, 12 channel).
The program features database of RADWAG pipettes and enables defining custom pipette models.
RADWAG pipettes are modern measuring equipment designed and manufactured in accordance with strict standards concerning manufacturing cleanliness and biodegradability of the product.
The pipettes represent a new line of the ‘liquid handling’ product group, designed to quickly measure and transport liquids of small volume. They are characterized by high dosing accuracy and ergonomic, solid design. The pipette mechanism ensures exceptional accuracy and repeatability with reduced pressure on the pipetting button.
All the pipettes are inspected for the conformity with the requirements of PN-EN ISO 8655 standard for dosing accuracy and repeatability. Each pipette is delivered with a test report featuring measurements results. The enclosed user manual contains a description of the pipetting techniques as well as verification and adjustment procedures that can be carried out by the user.
Calibration certificates, issued by the accredited calibration laboratory are available on request.
Metrological parameters
Volume | 0.5 μl — 10 μl /500 μl — 5000 μl
|
Systematic error | 2.0% / 0.5% – 2.5% / 1.0%
|
Random error | 1.5% / 0.8% – 0.6% / 0.15%
|
Tips | 10 μl – 5000 μl
|
OMNITIP™ – Bulk BT 1000, blue. 1000 µl, 250 tips in bulk.