Integrated MARS sensor for precise analysis of the best-sold model of Scope Electric®, for its compact size and low price and precise analysis.
Integrated MARS sensor for precise analysis of the best-sold model of Scope Electric®, for its compact size and low price and precise analysis.
Possibility to work at 220V, as well as 110V. Option to be powered by a car-battery for on-field analysis. Measurement start, without pushing a button. Made by ornamented INOX sheet.
INOX button and connection materials, ready to endure a humid environment.
Built-in device to cope with the electricity malfunctions. Automatic cleaning with “MilkoScope-Flush” concentrate. Message and sound signal for need of cleaning, after a certain period of work.
Calibration possibility from the analyzer’s built-in menu. Has 3 calibration channels, which can be calibrated for 3 types of milk.
PC-connection option, via software and cable, included in the kit. Perfect for all types of animal milk, as well as for special calibrations.
Thermal printer option.
pH-meter option.
Measuring Ranges: | Теchnical Overview: | ||
Fat: | 0% – 12% | Sample Volume: | 5-12 ml. |
Protein: | 0% – 7% | Sample Speed: | 65 sec. |
Lactose: | 0% – 7% | Sample Temperature: | 5 – 30°C |
Solids-Non-Fat (SNF): | 0% – 15% | Humidity: | 0 – 80% RH |
Solids: | 0% – 5% | Database Processing: | RS 232 port |
Density: | 1000-1200 kg/m3 | Power Supply: | 110/230VAC±10%,50/60Hz |
Added Water: | 0% – 100% | Power Consumption: | 30W |
Freezing Point: | -0,400 tо -0,700°C | Dimension: | H=270 mm,W=130 mm,D=280 mm |
Sample Temperature: | 5 – 30°C | Weight: | 3 kg |
Accuracy: | Кit: | |||
Fat: | ±0.03% | against Rose Gottlieb | Мilk Analyzer | |
Protein: | ±0.03% | against Kjeldahl | Power Supply Cable 220V | |
Lactose: | ±0.03% | against Polarimetry | Serial Cable to PC | 1piece |
Solids-Non-Fat (SNF): | ±0.05% | against Drying Oven | Sample Cup | 1piece |
Solids: | ±0.03% | against Gravimetric | Waste Container | 1piece |
Density: | ±0,3 kg/m3 | against pycnometer | Spare Hose | 1piece |
Added Water: | ±2% | against cryoscope | Cleaning Concentrate | 1piece |
Freezing Point: | 0,005 °C | User’s Manual | ||
CD with software |
Integrated MARS sensor for precise analysis. The innovative design and the built-in MARS sensor, make Julie C3™ Automatic very comfortable and easy for work.
Integrated MARS sensor for precise analysis. The innovative design and the built-in MARS sensor, make Julie C3™ Automatic very comfortable and easy for work. It is only necessary to tilt the automatic pipette into the special sample-cup and the measurement starts automatically. The sucked sample is not returned into the sample-cup, but goes into a waste-container. This helps for the lower littering of the milk’s way into the system.
The new sample pushes the previous one into the waste container and doesn’t affect the analysis results, even when there is a big difference in the Fat values of the two samples.This helps for the better accuracy of the milk analyzer. Julie C3™ Automatic is made entirely of 3 mm. aluminum sheet, equipped with laser-engraved INOX buttons.It has INOX connection parts, that can endure being in a humid place.
Automatic cleaning with “MilkoScope-Flush” concentrate. Message and sound signal for need of cleaning, after a certain period of work.
Has 3 calibration channels, which can be calibrated for 3 types of milk. Calibration possibility from the analyzer’s built-in menu. PC-connection option, via software and cable, included in the kit.
Julie C3™ Automatic is suitable for all types of animal milk. Perfect for all types of animal milk and for special calibrations. Thermal printer option.
pH-meter option.
Measuring Ranges: | Теchnical Overview: | ||
Fat: | 0% – 25% | Sample Volume: | 5-12 ml. |
Protein: | 0% – 15% | Sample Speed: | 60 sec. |
Lactose: | 0% – 20% | Sample Temperature: | 5 – 30°C |
Solids-Non-Fat (SNF): | 0% – 50% | Humidity: | 0 – 80% RH |
Solids: | 0% – 10% | Database Processing: | RS 232 port |
Density: | 1000-1200 kg/m3 | Power Supply: | 110/230VAC±10%,50/60Hz |
Added Water: | 0% – 100% | Power Consumption: | 40W |
Freezing Point: | -0,400 tо -0,700°C | Dimension: | H=310 mm,W=270 mm,D=270 mm |
Sample Temperature: | 5 – 30°C | Weight: | 5,2 kg |
pH: | 0 – 14 pH |
Accuracy: | Кit: | |||
Fat: | ±0.02% | against Rose Gottlieb | Мilk Analyzer | |
Protein: | ±0.02% | against Kjeldahl | Power Supply Cable 220V | |
Lactose: | ±0.02% | against Polarimetry | Serial Cable to PC | 1piece |
Solids-Non-Fat (SNF): | ±0.05% | against Drying Oven | RS 232 Cable | 1piece |
Solids: | ±0.02% | against Gravimetric | Thermal Printer Paper Roll | 1piece |
Density: | ±0,2 kg/m3 | against pycnometer | Sample Cup | 1piece |
Added Water: | ±1% | against cryoscope | Waste Container | 1piece |
Freezing Point: | 0,005 °C | Spare Hose | 1piece | |
pH: | ±0.02%pH | Cleaning Concentrate | ||
pH probe | ||||
pH solutions | ||||
User’s Manual | ||||
CD with software |
The new Julie C5™Automatic is a professional-class milk analyzer. The integrated MARS sensor contributes for the accurate performance of the milk analyzer.
The new Julie C5™Automatic is a professional-class milk analyzer. The integrated MARS sensor contributes for the accurate performance of the milk analyzer.
To start the analysis, it is not necessary to push a start-button. It is enough to put the sample-cup into the measurement-spot and the automatic pipette starts the analysis alone.
The measured sample is not returned back, but goes into a waste-container, that is included into the analyzer’s kit. This contributes for the accuracy of the measurement.
Even the biggest difference in the Fat-values of two samples does not affect the accuracy of the results. The milk suction is implemented by a high-class pump. It is made in a way, so to work for long years, without getting out of order. After a certain period of time, it must not be repaired, which is a must, when using peristaltic pumps, used by other milk analyzers manufacturers.
Julie C5™ is made of 3 mm. aluminum sheet. The software control is done by laser-engraved INOX buttons. All the milk analyzer’s connection parts are made of INOX that make the machine easy to use in a humid environment.
Julie C5™ has 3 calibration channels, which can be calibrated for 3 types of milk, at the base of the client’s choice.
Calibration possibility from the analyzer’s built-in menu. PC-connection option, via software and cable, included in the kit. Automatic cleaning with “MilkoScope-Flush” concentrate. Message and sound signal for need of cleaning, after a certain period of work. The milk analyzer has a built-in system to cope with the electricity malfunctions. Without this system, the results’ accuracy, will not be actual.
The new Julie C5™Automatic, model 2017, is equipped with new, high-quality printer, placed on the front-panel of the milk analyzer. It can print, by the operator’s choice, all the results of the measured parameters. It can be turned on and off by a special button on the analyzer’s keypad.
The new Julie C5™Automatic, model 2017 is suitable for work in the laboratory of big milk-processing plants, as well as in certified labs.
This milk analyzer is perfect for measuring all the types of animal milks, plant milks and special calibrations.
pH-meter option.
Measuring Ranges: | Теchnical Overview: | ||
Fat: | 0% – 20% | Sample Volume: | 5-15 ml. |
Protein: | 0% – 15% | Sample Speed: | 60 sec. |
Lactose: | 0% – 20% | Sample Temperature: | 5 – 30°C |
Solids-Non-Fat (SNF): | 0% – 20% | Humidity: | 0 – 80% RH |
Solids: | 0% – 10% | Database Processing: | RS 232 port |
Density: | 1000-1200 kg/m3 | Power Supply: | 110/230VAC±10%,50/60Hz |
Added Water: | 0% – 100% | Power Consumption: | 40W |
Freezing Point: | -0,400 tо -0,700°C | Dimension: | H=310 mm,W=270 mm,D=180 mm |
Sample Temperature: | 5 – 30°C | Weight: | 3,7 kg |
Accuracy: | Кit: | |||
Fat: | ±0.02% | against Rose Gottlieb | Мilk Analyzer | |
Protein: | ±0.02% | against Kjeldahl | Power Supply Cable 220V | |
Lactose: | ±0.02% | against Polarimetry | Serial Cable to PC | 1piece |
Solids-Non-Fat (SNF): | ±0.05% | against Drying Oven | RS 232 Cable | 1piece |
Solids: | ±0.02% | against Gravimetric | Thermal Printer Paper Roll | 1piece |
Density: | ±0,3 kg/m3 | against pycnometer | Sample Cup | 1piece |
Added Water: | ±1% | against cryoscope | Waste Container | 1piece |
Freezing Point: | 0,005 °C | Spare Hose | 1piece | |
Cleaning Concentrate | ||||
User’s Manual | ||||
CD with software |
The new Julie Z9 has an excellent accuracy and repeatability of the measured results. The new Z9 software automatically resets the machine at a certain period of time.
In the Julie Z9, we use two new peristaltic pumps, made by the best Japanese company for such pumps.
Now, the new Julie Z9 has an excellent accuracy and repeatability of the measured results.
The new Z9 software automatically resets the machine at a certain period of time.
It also cleans the analyzer automatically without human interference.
The new Z9 works with a measuring sensor and elements of a Japanese company, made with UV-technology.
With this sensor, the measured results are very precise and the calibrations never shift with time.
Knowing the quality of the new Z9, we bravely give one years of warranty of the milk analyzer and we are sure that our clients will enjoy working with it.
Measuring Ranges: | Теchnical Overview: | ||
Fat: | 0% – 50% | Sample Volume: | 3-12 ml. |
Protein: | 0% – 15% | Sample Speed: | 50 sec. |
Lactose: | 0% – 20% | Sample Temperature: | 5 – 40°C |
Solids-Non-Fat (SNF): | 0% – 50% | Humidity: | 0 – 80% RH |
Solids: | 0% – 10% | Database Processing: | RS 232 port |
Density: | 1000-1200 kg/m3 | Power Supply: | 110/230VAC±10%,50/60Hz |
Added Water: | 0% – 100% | Power Consumption: | 80W |
Freezing Point: | -0,400 tо -0,700°C | Dimension: | H=475 mm,W=375 mm,D=445 mm |
Sample Temperature: | 5 – 30°C | Weight: | 11,1 kg |
Accuracy: | Кit: | |||
Fat: | ±0.01% | against Rose Gottlieb | Мilk Analyzer | |
Protein: | ±0.01% | against Kjeldahl | Power Supply Cable 220V | |
Lactose: | ±0.01% | against Polarimetry | Serial Cable to PC | 1piece |
Solids-Non-Fat (SNF): | ±0.01% | against Drying Oven | RS 232 Cable | 1piece |
Solids: | ±0.01% | against Gravimetric | Thermal Printer Paper Roll | 1piece |
Density: | ±0,1 kg/m3 | against pycnometer | Sample Cup | 1piece |
Added Water: | ±1% | against cryoscope | Waste Container | 1piece |
Freezing Point: | 0,005 °C | Spare Hose | 1piece | |
Cleaning Concentrate | ||||
Hose for Waste Container | 1piece | |||
Containers for Flushing Solution | 2 piece | |||
User’s Manual | ||||
CD with software |
Julie X™ is a high-precision, pre-calibrated milk analyzer for analysis of milk and dairy products.
Milk Analyzer, featuring HIBRID nanooptics technology! Julie X™ is a high-precision, pre-calibrated milk analyzer
for analysis of milk and dairy products.
Julie X™ offers a cost effective way for quality control of:
|
|
The new Julie X ™ is the only milk analyzer capable of analyzing cream with up to 60% fat without diluting in water. It can also be calibrated for three customer selected products.
Julie X™ is calibrated according to established standard methods for milk analysis:
Roesse Gottlieb – for fat
Kieldahl – for protein
HPCL – for lactose
Oven drying – for total solids
Cryoscopy – for freezing point
MEASURED PARAMETERS
Parameter | Accuracy (Resolution) | Range | Consistency (Repeatability) |
Fat | 0.01% | 0.00% – 60.00% | ± 0.01 |
SNF | 0.01% | 0.00% – 60.00% | ± 0.01 |
Protein | 0.01% | 0.00% – 25.00% | ± 0.01 |
Lactose | 0.01% | 0.00% – 25.00% | ± 0.01 |
Density | 0.0001 | 1.0400 | ± 0.001 |
Solids | 0.01% | 0.00% – 5.00% | ± 0.01 |
Freezing Point | 0.001 °C | -1.000 °C to 0.000 °C | ± 0.001 °C |
Sample volume: 10 ml
Sample temperature: 2 to 45 °C
Dimensions (W x D x H): 42 x 40 x 37 cm
Weight: 11 kg
Power supply: 12V = 6A, 72W
Human Milk Analyzer, featuring HIBRID nanooptics technology! Julie X HMA™ is a high-precision milk analyzer for human milk analysis, offered at one tenth of the price of other devices for measuring human milk.
Human Milk Analyzer, featuring. HIBRID nanooptics technology! Julie X HMA™ is a high-precision milk analyzer for human
milk analysis, offered at one tenth of the price of other devices for measuring human milk.
Only with a 5 ml of sample material, within 60 seconds you get measured results for:
The results are instantly shown on the display and can also be printed or transferred to a PC via USB connection.
Julie X HMA™ is calibrated according to established standard methods for human milk:
Roesse Gottlieb – for fat
Kieldahl – for protein
HPCL – for lactose
Oven drying – for total solids
Cryoscopy – for freezing point
MEASURED PARAMETERS
Parameter | Accuracy (Resolution) | Range | Consistency (Repeatability) |
Fat | 0.01% | 0.00% – 20.00% | ± 0.01 |
SNF | 0.01% | 0.00% – 20.00% | ± 0.01 |
Protein | 0.01% | 0.00% – 25.00% | ± 0.01 |
Lactose | 0.01% | 0.00% – 25.00% | ± 0.01 |
Density | 0.0001 | 1.0400 | ± 0.001 |
Solids | 0.01% | 0.00% – 5.00% | ± 0.01 |
Freezing Point | 0.001 °C | -1.000 °C to 0.000 °C | ± 0.001 °C |
Sample volume: 5 ml
Sample temperature: 2 to 45 °C
Dimensions (W x D x H): 42 x 40 x 37 cm
Weight: 11 kg
Power supply: 12V = 6A, 72W
The solution prepared from this concentrate excellently cleanses and disinfects the measuring system of the MilkoScope Milk analyzers and prolongs their life.
The solution prepared from this concentrate excellently cleanses and disinfects the measuring system of the MilkoScope Milk analyzers and prolongs their life.
One liter of the concentrate is enough for the preparation of 200 liters of MilkoScope – Flush cleaning solution.
Please use this solution, following the instructions of Scope Electric®.
We offer the MilkScope – Flush cleaning concentrate in bottles of 500 ml. (for the preparation of 100 l. MilkoScope – Flush cleaning solution) and in bottles of 1000 ml. (for the preparation of 200 l. MilkoScope – Flush cleaning solution).
When you purchase a milk analyzer, you receive 1 bottle (500 ml.) of the MilkoScope – Flush cleaning concentrate.