Model | Model WM-040-1004 (IR) |
Light Source | IR LED (860 nm) |
Regulatory Compliance | ISO 7027 |
Measuring Principle | Nephelometric (Multipath 90° BLAC) |
Measuring Range | 0.01 – 4000 NTU (FNU) |
Resolution | Auto ranging: 0.01-9.99: 0.01 NTU ; 10.0-99.9: 0.1 NTU ; 100-4000: 1 NTU |
Accuracy | ± 1.8 % of reading + straylight |
Repeatability | < 1 % or ± 0.01 NTU |
Stray Light | < 0.014 NTU |
Display Units | NTU, FNU, Degrees, mg/L Kaolin, mg/L PSL |
Response Time | 7 seconds |
Reading Modes | Single, Signal Averaging, Fast-Settling |
Calibration Options | Full-range calibration from 0 – 4000 NTU |
Detector | Silicon Photodiode |
Ratio Mode | Yes |
Sample Required | 10 mL (0.4 oz) |
Display | Full-Colour Touchscreen |
Display Size | 55 x 95 mm (W x H) |
Interfaces | USB-A USB-C |
Data Logger | 250 measurements, all calibrations, verifications and factory-restore actions |
Data Transfer Format | .csv |
Power Save Mode | Yes |
Auto – OFF | Selectable |
Power Supply | 4 batteries (AA) 3 NiMH-battery pack (AA) Universal (90 – 240 VAC), via external power supply |
Environmental Conditions | Temperature: 0 – 50 °C (32 – 122 °F) Humidity: 0 – 90 % at 30 °C, noncondensing Humidity: 0 – 80 % at 40 °C, noncondensing Humidity: 0 – 70 % at 60 °C, noncondensing |
Protection Class | IP 67 (Instrument) |
Compliance | CE CSA FCC A RoHS TÜV UL WEE |
Languages User Interface | German, English, French, Spanish, Portuguese, Chinese, Japanese, Dutch, Turkish, Polish |
Languages Quick Start Guide | German, English, French, Spanish, Italian, Portuguese, Chinese, Dutch, Turkish, Russian |
Languages Full User Manual | German, English, French, Spanish, Italian, Portuguese, Chinese, Dutch, Turkish, Russian |
Dimensions | 155 x 83 x 225 mm |
Weight | 804 g (898 g with four AA alkaline batteries) |
Weight with Packaging | (898 g with four AA alkaline batteries) |
Model | Model WM-040-1001 (WL) |
Light Source | White LED |
Regulatory Compliance | EPA approved (alternative to US EPA 180.1) |
Measuring Principle | Nephelometric (Multipath 90° BLAC) |
Measuring Range | 0.01 – 4000 NTU (FNU) |
Resolution | Auto ranging: 0.01-9.99: 0.01 NTU ; 10.0-99.9: 0.1 NTU ; 100-4000: 1 NTU |
Accuracy | ± 1.8 % of reading + straylight |
Repeatability | < 1 % or ± 0.01 NTU |
Stray Light | < 0.014 NTU |
Display Units | NTU, FNU, Degrees, mg/L Kaolin, mg/L PSL |
Response Time | 7 seconds |
Reading Modes | Single, Signal Averaging, Fast-Settling |
Calibration Options | Full-range calibration from 0 – 4000 NTU |
Detector | Silicon Photodiode |
Ratio Mode | Yes |
Sample Required | 10 mL (0.4 oz) |
Display | Full-Colour Touchscreen |
Display Size | 55 x 95 mm (W x H) |
Interfaces | USB-A USB-C |
Data Logger | 250 measurements, all calibrations, verifications and factory-restore actions |
Data Transfer Format | .csv |
Power Save Mode | Yes |
Auto – OFF | Selectable |
Power Supply | 4 batteries (AA) 3 NiMH-battery pack (AA) Universal (90 – 240 VAC), via external power supply |
Environmental Conditions | Temperature: 0 – 50 °C (32 – 122 °F) Humidity: 0 – 90 % at 30 °C, noncondensing Humidity: 0 – 80 % at 40 °C, noncondensing Humidity: 0 – 70 % at 60 °C, noncondensing |
Compliance | CE CSA FCC A RoHS TÜV UL WEE |
Languages User Interface | German, English, French, Spanish, Portuguese, Chinese, Japanese, Dutch, Turkish, Polish |
Languages Quick Start Guide | German, English, French, Spanish, Italian, Portuguese, Chinese, Dutch, Turkish, Russian |
Languages Full User Manual | German, English, French, Spanish, Italian, Portuguese, Chinese, Dutch, Turkish, Russian |
Dimensions | 155 x 83 x 225 mm |
Weight | 804 g (898 g with four AA alkaline batteries) |
Weight with Packaging | (898 g with four AA alkaline batteries) |
The compact Lovibond® infrared turbidity measuring instrument TB 211 IR for fast and accurate on-site analysis. It is measured as provided in EN ISO 7027, the scattered light at an angle of 90 °.
The wide measuring range from 0.01 to 1100 TE / F = NTU = FNU with a detection limit of 0.01 NTU allows the use of the device in different areas, from drinking water to wastewater.
Since the measurements are made by means of infrared light, both colored and colorless water samples can be measured. A direct transfer of the measurement results to a PC is through the USB interface TB 211 IR easy to set up. The necessary USB cable is already part of the delivery.
Optics | temperaturecompensated LED ( λ = 860 nm) and photosensor amplifier in water proof sample chamber, infrared light |
Measuring Principle | nephelometric (90° scattered light) |
Measuring Range | 0,01-1100 NTU (Autorange) |
Accuracy | ± 2.5 % of reading, or ± 0.01 NTU, whichever is bigger, in the range of 0.01 – 500 NTU ; ± 5 % of reading in the range of 500 – 1000 NTU |
Suitable Vials | Round Cuvettes 24 mm |
Display | backlit LCD |
Interfaces | Micro-USB |
Operation | polycarbonate membrane, splash proof |
Auto – OFF | Yes |
Internal Storage | internal ring memory for 125 data sets |
Power Supply | 9 V-block |
Clock | Real Time Clock and Date |
Portability | Portable |
Environmental Conditions | 5 – 40 °C at 30 – 90 % relative humidity (non condensing) |
Compliance | CE |
Dimensions | 110 x 55 x 190 mm |
Weight | 400 g (Basic unit) |
Weight with Packaging | (Basic unit) |
Turbidity is measured according to EN ISO 7027 by nephelometric means (90° scattered light). The infrared light-source permits measurement of coloured and colour-free samples. The automatic measurement range detection facility (Autorange) enables direct turbidity measurement from 0.01 to 1100 NTU with an accuracy of ± 2 %
up to 500 NTU and ± 5 % thereafter. A large graphic display, a choice of several different languages and user-friendly operating instructions make the device extremely easy to use. Software updates (for example: languages) can be downloaded free of charge from our website www.lovibond.com.
Optics | Turbidity is measured according to EN ISO 7027 by nephelometric means (90° scattered light) |
Measuring Principle | nephelometric (90° scattered light) |
Measuring Range | 0.01 – 1100 NTU (Autorange) |
Accuracy | ± 2 % of reading, or ± 0.01 NTU, whichever is bigger, in the range of 0.01 – 500 NTU ; ± 5 % of reading in the range of 500 – 1000 NTU |
Suitable Vials | Round Cuvettes 24 mm |
Display | Graphic-Display |
Interfaces | RS 232 |
Operation | acid and solvent resistant; membrane keypad |
Auto – OFF | Yes |
Calibration | automatic overall range adjustment with Standard-Set T-Cal |
Updates | Software update via Internet |
Internal Storage | 1000 data sets |
Power Supply | 7 NiMH-battery pack (AA/Mignon) Universal (90 – 240 VAC), via external power supply |
Clock | Real Time Clock |
Portability | Benchtop |
Environmental Conditions | 5 – 40 °C at 30 – 90 % relative humidity (non condensing) |
Compliance | CE |
Dimensions | 265 x 195 x 70 mm |
Weight | 1000 g (incl. batteries) |
Weight with Packaging | (incl. batteries) |
Turbidity is measured according to EN ISO 7027 by nephelometric means (90° scattered light). The infrared light-source permits measurement of coloured and colour-free samples. The automatic measurement range detection facility (Autorange) enables direct turbidity measurement from 0.01 to 1100 NTU with an accuracy of ± 2 %
up to 500 NTU and ± 5 % thereafter. A large graphic display, a choice of several different languages and user-friendly operating instructions make the device extremely easy to use. Software updates (for example: languages) can be downloaded free of charge from our website www.lovibond.com.
Optics | Turbidity is measured according to EN ISO 7027 by nephelometric means (90° scattered light) |
Measuring Principle | nephelometric (90° scattered light) |
Measuring Range | 0.01 – 1100 NTU (Autorange) |
Accuracy | ± 2 % of reading, or ± 0.01 NTU, whichever is bigger, in the range of 0.01 – 500 NTU ; ± 5 % of reading in the range of 500 – 1000 NTU |
Suitable Vials | Round Cuvettes 24 mm |
Display | Graphic-Display |
Interfaces | RS 232 |
Operation | acid and solvent resistant; membrane keypad |
Auto – OFF | Yes |
Calibration | automatic overall range adjustment with Standard-Set T-Cal |
Updates | Software update via Internet |
Internal Storage | 1000 data sets |
Power Supply | 7 NiMH-battery pack (AA/Mignon) Universal (90 – 240 VAC), via external power supply |
Clock | Real Time Clock |
Portability | Benchtop |
Environmental Conditions | 5 – 40 °C at 30 – 90 % relative humidity (non condensing) |
Compliance | CE |
Dimensions | 265 x 195 x 70 mm |
Weight | 1000 g (incl. batteries) |
Weight with Packaging | (incl. batteries) |
The TB 250 WL allows easy turbidity measurement in either the field or in the laboratory. Using a „white light“ source and 90° detection, the TB 250 WL meets the specifications for EPA turbidity measurement (EPA Standard 180.1). A power efficient micro-circuit design allows the instrument to yield 5000 tests on 4-AA alkaline batte-
ries with an estimated 7-10 year bulb life. Integrated diagnostics confirm proper operation and accuracy. The instrument features an Auto-Ranging feature that automatically selects the correct turbidity range for your sample. Calibration is simple with the included calibration standards. The instrument comes with all required items for testing including the TB 250 WL Turbidimeter, sample cuvettes, batteries, calibration set, operators manual and carrying case.
Measuring Principle | nephelometric (90° scattered light) |
Measuring Range | 0,01 bis 1100 NTU |
Display | large LCD display |
Operation | 5 key polycarbonate membrane, splash proof |
Auto – OFF | Yes |
Power Supply | 4 batteries (AA) |
Portability | Portable |
Environmental Conditions | 0 – 50 °C at 0 – 90 % relative humidity (non condensing) |
Compliance | CE |
Dimensions | 95 x 45 x 210 mm |
Weight | 450 g (Basic unit) |
Weight with Packaging | (Basic unit) |