Professional air purification equipment suitable for pharmaceuticals, medical and health industries, scientific research laboratories of universities and colleges as well as other related fields.
Available in all countries and regions from 100 to 230V, 50/60Hz
Dual DC fans
Dual wind speed sensors
Dual Ultra High Efficiency Filters (ULPA)
One-piece welded cabinet construction
Platform arm rest frame. comfortable to use,relieves fatigue.
● The inner liner is manufactured with stainless steel one-piece structure design,12mm large arc transition,no dead angles to clean.
● The work surface is manufactured with high quality 304 stainless steel,without any fixed screws,preventing any accumulation pollutants.
● The cabinet is manufactured with cold rolled steel plate with corrosion resistant epoxy resin powder sprayed on the surface,which is resistant to acid and alkali corrosion.
Model | Power Supply (V/Hz) | Power of Blower (W) | Downflow Velocity (m/s) | Exhaust Filter Typical Efficiency | Main Filter Typical Efficiency | Airflow Circulation | Size(Width) | Sash Opening |
HR900-IIA2-N | 100~230/50/60 | DC 190W 112W | 0.35 | ULPA,U15,99.9995%@0.12um | ULPA ,U15,99.9995%@0.12um | 70% Downflow, 30% Exhaust | 1040mm | 890mm |
HR1800-IIA2-N | 100~230/50/60 | DC 120W 112W | 0.35 | ULPA,U15,99.9995%@0.12um | ULPA,U15,99.9995%@0.12um | 70% Downflow, 30% Exhaust | 1940mm | 1830mm |
HR1200-IIA2-N | 100~230/50/60 | DC 120W 112W | 0.35 | ULPA,U15,99.9995%@0.12um | ULPA,U15,99.9995%@0.12um | 70% Downflow, 30% Exhaust | 1340mm | 1230mm |
The X series of standard Class II microbiological safety cabinets are suitable for basic cell biology, microbiology, biomedicine, biosafety laboratories and other laboratories. It is the most basic protection and isolation equipment for biosafety.
Dual: SMI pressure sensors, light airflow speed sensors, EBM DC fans, ULPA filters, lights
Intelligent constant air velocity function
Airflow blocking patented technology
HEPA filter service life warning function
UV lamp service life warning and one-touch timer function
With an Operational Front Window Interlocking with the UV Lamp, LED Lamp and Fan Intelligently to Ensure Better Security
Model | Power Supply (V/Hz) | Power of Blower (W) | Downflow Velocity (m/s) | Exhaust Filter Typical Efficiency | Main Filter Typical Efficiency | Airflow Circulation | Size(Width) | Blowers | Sash Opening |
HR1200-IIA2-X | 220/60;220/50 | DC 120 112 | 0.3 | ULPA,U15,99.9995%@0.12um | ULPA,U15,99.9995%@0.12um | 70% Downflow, 30% Exhaust | 1336mm | Dual | 1230mm |
HR1500-IIA2-X | 220/60;220/50 | DC 190 112 | 0.33 | ULPA,U15,99.9995%@0.12um | ULPA,U15,99.9995%@0.12um | 70% Downflow, 30% Exhaust | 1636mm | Dual | 1530mm |
HR1800-IIA2-X | 220/60;220/50 | DC 120 112 | 0.3 | ULPA,U15,99.9995%@0.12um | ULPA,U15,99.9995%@0.12um | 70% Downflow, 30% Exhaust | 1936mm | Dual | 1830mm |
Energy efficient Class II microbiological safety cabinet with two DC fans, dual exhaust HEPAs and long lasting LED lights. Suitable for microbiology, biomedicine, biosafety laboratories and other laboratories. It offers three levels of protection – operator, product and environment.
● The HR1200-IIA2 double exhaust filtered biological safety cabinet utilises two highly efficient HEPA exhaust filters and one ULPA downflow filter to provide three levels of protection; operator, product and environment.
● As there is no need for external ducting, this is a cost- effective solution.
● The unit is certified to the EN 12469 standard. It uses energy efficient DC fans, as well as LED lights to ensure for optimal performance with a low noise output and reduce energy consumption. The ergonomic design ensures maximum comfort and alleviates operator fatigue.
● The units utilise side air design on the upper edge and on both sides of the front window to eliminate ‘blind spots’. This prevents crossflow between inside and outside air thus reducing the risk of contamination. The compartmented working surface can easily be removed for sterilization and cleaning.
● E.U. EN12469 Standard Certification.
● The main filter uses a damp-proof, fire-proof glass fibre ULPA filter, the filtering efficiency for ≥0.12μm particulate matter is ≥99.9995% which provides cleaner air and safer samples.
● EC fan operates with lower noise and better uniformity air flow.
● LCD screen displays various parameters and clear operational conditions.
● Ultraviolet light can be set with one single key to automate on/off time, and sterilization time interval from 0 to 24 hours, reducing downtime.
● The product features an interlocking function between the ultraviolet sterilization, fluorescent lamp, front window and fan motor meaning the UV lamp can only come on when illuminating lamp is off. This failsafe removes the risk of incorrect operation.
● Equipped with multiple visual and sound alert functions, it is clear and easy to understand. Alarms include filter and UV end-of-life alerts, fan turned-off after door opening alert and door open alarm.
● Two IP44 rated waterproof sockets with timed on/off function to improve safety and conserve energy.
● 10° angled front window provides a comfortable work space for operators.
● Adjustable height stands with hidden mechanism to avoid contamination.
● Universal castors with self-levelling feet for convenient moving.
● Drop-down front window design for easier cleaning of the upper edge of glass.
● Removable hand rest reduces arm fatigue and does not interfere with air inflow.
● Optional accessories include water valve (manual/electric), air valve and VHP sterilizer.
● Optional electric door or electric underframe.
● Fan turn-off alarm after door opening.
● Abnormal door height alarm.
● Door open more than limit.
● Blocked filter alarm.
● Damaged filter alert.
● Filter and UV end-of-life alert.
● Front glass blocks ultraviolet .
Model | Power Supply (V/Hz) | Power of Blower (W) | Downflow Velocity (m/s) | Exhaust Filter Typical Efficiency | Main Filter Typical Efficiency | Airflow Circulation | Size(Width) | Blowers | Sash Opening |
HR1200-IIA2-D | 220/60;220/50 | DC 190, DC 170 | 0.3 | TWO HEPA,H14,99.995%@0.3um | ULPA,U15,99.9995%@0.12um | 70% Downflow, 30% Exhaust | 1380mm | Single | 1310mm |
These are standard Class II microbiological safety cabinets suitable for basic cell biology, microbiology, biomedicine, biosafety laboratories and other laboratories. It is the most basic protection and isolation equipment for biosafety.
● Certified to EN12469.
● Damp-proof, fire-proof glass fibre HEPA filter with a filtering efficiency for ≥0.3μm particulate matter is ≥99.995% provides cleaner air and safer samples.
● Dual DC fans allow for better air flow uniformity and operate with lower noise.
● LCD screen displays various parameters and clear operational conditions.
● UV lamp can be set with one single key to activate/deactivate automatically at specified sterilization intervals from 0min to 24hrs, to minimize the waiting time.
● The product features an interlocking function between the ultraviolet sterilization, fluorescent lamp, front window and fan motor meaning the UV lamp can only come on when the illuminating lamp is off. This failsafe removes the risk of incorrect operation.
● Multiple audible and visual alarms: hardware malfunction alarm, operating parameter overrun alarm, filter/UV lamp lifecycle ending alarm, etc.
● Two IP44 rated water-proof sockets with timed on/off function for improved safety and energy conservation.
● Optional electric door or electric underframe.
● 10 angled front window provides a comfortable work space for operators.
● Adjustable height stand with hidden mechanism to avoid contamination.
● Universal castor for convenient moving.
● Drop-down front window design for easier cleaning of the upper edge of glass.
● Removable hand rest reduces arm fatigue and does not interfere with air inflow.
● Optional accessories include water valve (manual/ electric), air valve, VHP sterilizer and electric door function (door electric motor and foot switch).
Model | Power Supply (V/Hz) | Power of Blower (W) | Downflow Velocity (m/s) | Exhaust Filter Typical Efficiency | Main Filter Typical Efficiency | Airflow Circulation | Size(Width) | Blowers | Sash Opening |
HR1200-IIA2-S | 220/60;220/50 | DC 120 112 | 0.3 | HEPA ,H14,99.995%@0.3um | HEPA ,H14,99.995%@0.3um | 70% Downflow, 30% Exhaust | 1380mm | Single | 1310mm |
HR900-IIA2 | 220/50 | AC-L=330,M=465,H=735 | 0.33 | ULPA,U15,99.9995%@0.12um | ULPA,U15,99.9995%@0.12um | 70% Downflow, 30% Exhaust;70% Downflow | 1080mm | Single | 920mm |
HR1200-IIA2 | 220/50 | AC-L=330,M=465,H=735 | 0.34 | HEPA ,H14,99.995%@0.3um | ULPA,U15,99.9995%@0.12um | 70% Downflow, 30% Exhaust | 1380mm | Single | 1220mm |
HR1500-IIA2 | 220/50 | AC 650 | 0.31 | HEPA ,H14,99.995%@0.3um | ULPA,U15,99.9995%@0.12um | 70% Downflow, 30% Exhaust | 1680mm | Single | 1520mm |
The Haier Biomedical Biological Safety Cabinet is designed to protect the operator, laboratory environment and samples from being exposed to the infective aerosol produced from samples with bacteria strains, diagnostic materials, and other infective substances. It provides the operator with comfortable and safer working conditions. It is widely used in medical health, disease prevention, food safety, biological pharmacy and environment monitoring.
Ultra-efficient air filter (ULPA)
Superior filtering effects 99.9995% for 0.12μm particles
Volute forward centrifugal fan
Sound and light alarm function
UV lamp sterilization timed startup
Ergonomic 10 degrees tilt design
With CE and TÜV SÜD Mark Certification
● Stainless steel work surface without screws ensures no accumulation of contaminant
● Removable air in-flow plate is easy to clean and disinfect
● Internal wall is constructed of a single piece stainless steel, with 12mm arc angle corners which allows for more effective cleaning
● The volume of liquid tank is over 4L, equipped with outlet valve for convenient cleaning and maintenance
● Concaved work surface, waste liquid easily collected
● Adjustable stand (0-75mm) without exposed screw thread, reduces risk of contamination
● American AAF ULPA filter
● Tested to a typical efficiency of 99.9995% for 0.12 micron particles
● Provides FED STD 209E class 1 (or ISO14644.1 class 3) clean air to work surface in a stable vertical laminar flow to protect samples
● The exhaust ULPA filter traps biohazard particles acquired from the work surface before air is exhausted to the room, offering personnel and environmental protection
● The blower system is designed for high performance operation, maximum energy efficiency and minimal maintenance
● Self cooling system reduces energy consumption while enhancing reliability
Model | Power Supply (V/Hz) | Power of Blower (W) | Downflow Velocity (m/s) | Exhaust Filter Typical Efficiency | Main Filter Typical Efficiency | Airflow Circulation | Size(Width) | Blowers | Sash Opening |
HR40-IIA2 | 115/60;220/60;220/50 | AC 540/625 | 0.28;0.3 | HEPA ,H14,99.995%@0.3um | ULPA,U15,99.9995%@0.12um | 70% Downflow, 30% Exhaust | 1360mm | Single | 1167mm |
HR30-IIA2 | 220/60;220/50 | AC 540/625 | 0.3 | HEPA ,H14,99.995%@0.3um | ULPA,U15,99.9995%@0.12um | 70% Downflow, 30% Exhaust | Size(Width)1100mm | Single | 900mm |
HR40-IIB2 | 220/60;220/50 | AC115 | 0.3 | HEPA ,H14,99.995%@0.3um | ULPA,U15,99.9995%@0.12um | 100% Exhaust | 1360mm | Single | 1167mm |
Professional air purification equipment suitable for the test environments of small spaces and single person operations, such as virus sampling warehouses, sampling stations at airports and railway stations, on-board laboratories, and other space limited organizations.
Standard Electric Glass Door
Interlocking Function
2 Valve Interfaces
Air Velocity Sensor
Uniform Airflflow
Adopts AAF filters, class 1 cleanliness, provides strong protection for people, environment and samples
EBM fan, combined with professional air distribution design, has lower noise and more uniform air flow
AAF filter, high efficiency and uniformity, low resistance
Model | Power supply (V/Hz) | Airflow Circulation | InflowVelocity (m/s) | Lighting Intensity (Lux) | Internal Dimensions (W*D*H) | External Dimensions (W*D*H) |
HR700-IIA2 | 220/50/60 | 70%Downflow,30%Exhaust | 0.45 | ≥650 | 600*550*540(mm) | 700*710*1200(mm) |