Developed in collaboration with the TOTAL Research Center, this sulfur analyzer meets the essential need of oil refineries. Users participation in its design justifies its performances, robustness and ease of use.
It allows to:
Analyzer according the Standards ASTM D5453, ASTM D6667, ASTM D7183, ISO 20 846
Your tranquility counts: with our new analyzers, you no longer need to choose an analysis method or a measurement range depending on the concentration of your samples.
The analyzer will do it automatically.
Principle Sulur: UV Fluorescence
Detection Limit: 5 ppb to 10% Accuracy / RSD:
Injections : 20 to 80 µl liquids | 10 ml gas | 20µL LPG For solid samples, with 0.5 to 100 mg boats | Supply Gas:
Electric: 110 V / 230 V Temperature :
|
Thanks to the new generation of 2E detectors, we have developed an analyzer to measure both sulfur and nitrogen simultaneously on a single sample.
This elemental analyzer allows:
Analyser according the standards ASTM D5453, ASTM D6667, ASTM D7183, ISO 20846, ASTM D4629, ASTM D6069, ASTM D5176, ASTM D5762, NF EN 12260
It automatically and rapidly measures the very low levels of sulfur / nitrogen in petroleum products: up to 10 ppb of sulfur and 10 ppb of nitrogen. It can also be associated with the liquid injector or the liquid automatic sampler, or the Gas / LPG AUTOMATIC sampler.
Your tranquility counts: with our new analyzers, you no longer need to choose an analysis method or a measurement range depending on the concentration of your samples.
The analyzer will do it automatically.
Principle Sulur/Nitrogen : UV Fluorescence / Chemiluminescence
Detection Limit:5 ppb S / 5 ppb N to 10% Quantification :10 ppb S / 10 ppb N to 10%
Accuracy S/ RSD S:
Accuracy N / RSD N:
| Injections : 20 to 80 µl liquids | 10ml gas | 20µL LPG
Supply Gas:
Electric: 110 V / 230 V
Temperature :
|
Our Multi-E analyzer allows the analysis of Sulfur, Nitrogen and Total Chlorine.
1 SINGLE device = 3 elements measured = save time, space and money!
Sulfur and Nitrogen Analysis:
Thanks to the new generations of 2E detectors, we have developed an analyzer allowing us to measure these two elements quickly and reliably: Sulfur by UV Fluorescence and Nitrogen by Chemiluminescence.
Total Chlorine Analysis:
The Multi-E , in addition to Sulphur and Nitrogen, can measure total Chlorine (and other halogens) by argentometric coulometry. Its measurement capacity extends from traces (< 0.5 ppm) to basic elemental chlorine (> 80%, without dilution).
Thanks to its optimized design, you can analyze sulfur, nitrogen, and chlorine simultaneously. Thanks to its two separate combustion lines, you’ll be protected from any potential interference or pollution. Each combustion line has its own automatic injector with up to six positions.
This Multi-E Analyzer allows you to:
|
|
The Multi-E Analyzer complies with the following standards:
– For Sulfur : ASTM D5453, ASTM D6667, ASTM D 7183, ISO 20 846
– For Nitrogen: ASTM D4629, ASTM D6069, ASTM D5176, ASTM D5762, NF EN 12260
– For Chlorine: ASTM D4929, ASTM D5808, ASTM D5194, ASTM D6721, UOP 779, ISO 9562, NF EN 12260, NF EN 14077
It automatically and quickly measures very low sulfur/nitrogen/chlorine levels in petroleum products, oils, water and other products…: up to 10 ppb of sulfur and 10 ppb of nitrogen. For chlorine, its detection limit is < 0.1 ppm at more than 80%.
It can also be associated with the injector or the liquid sampler, or even with the Gas/LPG sampler.
Choose peace of mind: With our new analyzers, you no longer need to choose an analysis method or measurement range based on the concentration of your samples.
The analyzer does this automatically.
Sulfur/Nitrogen Principle: UV Fluorescence / Chemiluminescence
Detection limit: 5 ppb S / 5 ppb N at 10% Quantification: 10 ppb S / 10 ppb N at 10%
Precision S / Standard deviation S:
Precision N / Standard deviation N:
Injections: 20 to 80 µl liquid | 10 ml gas | 20µL LPG | Chlorine Principle: Coulometry
Detection limit: 50 ppb to more than 80% Quantification: < 0.1 ppm to more than 80%
Gas supply:
Electric: 110V / 230V
Temperature :
|
Designed to meet the specific needs of petroleum refineries, this nitrogen analyzer was developed in collaboration with TOTAL Research Center.
This participation of the end user in its design justifies it’s high level of performance, robustness and ease of use.
It allows to:
Nitrogen analyzer by Chemiluminescence, according ASTM D4629, ASTM D6069, ASTM D5176, ASTM D5762, NF EN 12260
It can be combined with the liquid automatic sampler, or the Gas / LPG AUTOMATIC sampler.
Your tranquility counts: with our new analyzers, you no longer need to choose an analysis method or a measurement range depending on the concentration of your samples.
The analyzer will do it automatically.
Principle Nitrogen: Chemiluminescence
Detection Limit: 5 ppb to 10%
Accuracy / RSD:
Injections : 20 to 80 µl liquids | 10 ml gas | 20µL LPG
For solid samples, with 0.5 to 100 mg boats | Supply Gas:
Electric: 110 V / 230 V
Temperature :
|
The HELIOS CL, is an analyzer used to measure total chlorine (and other halogens) by means of coulometric method.
Its measuring capacity extends from traces (<0.5 ppm) to the high concentrations of total chlorine (> 80%). It is also used to measure chlorine On Chlorinated PVC-C. In addition to the accessories for measuring EOX and POX, we offer complete equipment for AOX dosing by agitation and absorption.
Chlorine and AOX analyzer according to the standard ASTM D4929, ASTM D5808, ASTM D5194, ASTM D6721, UOP 779, ISO 9562, NF EN 12260, NF EN 14077
This analyzer is compose with two furnaces, and ensures complete combustion of your samples. The furnace F1 constitutes a real micro reactor, allowing a great flexibility of use. It allows you to program controlled pyrolysis and combustion of your samples through temperature sequences. With this technology, you will no longer generate soot regardless of the nature of the sample and the position of the furnace (vertical or horizontal)
Principle Chlorine: Coulometry
Injections : 20 to 80 µl liquids | 20µL LPG | 0.5 to 100mg
Supply Gas:
| Electric: 110 V / 230 V
Temperature :
|
Our apparatus having an Oxy-hydrogen burner is used to determine total sulfur by the Wickbold method.
This test method covers the determination of total sulfides in liquefied petroleum gases containing more than 1 μg / g. Samples must contain less than 100 μg / g of halogen.
Standards ASTM D2784, AFNOR M41-009, ISO 4260, IP 243, DIN 51408
The normative references for this equipment are relatively old, but they are still current in a number of laboratories, in industry and research. This equipment offers the possibility for laboratories to acquire, at a reduced cost, equipment for the determination of total sulfur and possibly fluorine.
Other Sulfur / Nitrogen Measurement Equipment
RACKS SO2 and NO2: Measuring racks of continuous sulfur or nitrogen in gases, alimentary CO2 for example. With a built-in permeation bench and certified COS tube.
Principle: WICKBOLD Method
Sulfur measurement in:
Safety:
|
Supply Gas:
Electric: 110 V / 230 V
Température: Stainless steel Burner, up to 2000°C |
In collaboration with the French Petroleum Institute (I.F.P), we have developed one of the first gas and LPG automatic samplers that meets the requirements of ASTM D666. This equipment is not restricted to the brand ERALY only, it can be used on other brands devices as well. It is easy to use and requires very little maintenance.
We offer it for sampling and injecting gas and/or LPG.
In order to respond specifically to some of your needs, you can also buy it either for gas alone or for LPG alone, at a reduced price.
By listening to the needs and requests of our customers, we have developed a liquid automatic sampler with 25 to 50 positions.
It allows to:
In the same spirit, we have developed a Mini-Auto Sampler “Mini-D” for our customers with a relatively small number of samples.
This will offer them the possibility to automate their operations at a lower cost, because our “Mini-D” can automatically inject between 5 and 7 different samples.