Testers

Testers
  • EC/TDS/Salinity
  • Dissolved Oxygen
  • Multiparameter
  • Application Specific
  • pH/ORP
  • ISE
  • EC/TDS/Salinity
  • Dissolved Oxygen
  • Multiparameter
  • Autosampler Titrators
  • Karl Fischer Titrators
  • Mini Titrators
  • Potentiometric Titrators
  • Benchtops
  • Checker Colorimeters
  • Portable Photometers
  • Spectrophotometers
  • Benchtops Turbidimeters
  • Portable Turbidimeters
  • Testers
  • Thermocouples
  • Thermistors
  • Pt100
  • Monitors
  • Backpacks Labs
  • Single Parameters
  • ABS Plastic
  • Stainless Steel
  • Monitors
  • Dataloggers
  • Controllers and Transmitters
  • Dosing Pumps
  • Mini Controllers
  • PCA Chlorine
  • Probes
  • Swimming Pool and Spa Controllers
  • pH
  • ORP
  • ISE
  • TDS
  • Dissolved Oxygen
  • Temperature
  • Multiparameter
  • Bluetooth
  • Photometric Probes
  • Checker HC
  • Chemical Test Kits
  • Photometers
  • Titration
  • Calibration Solutions
  • Fill Solutions
  • Storage Solutions
  • Cleaning Solutions
  • Sample Prep Solutions
  • ISE Solutions
  • Titration Solutions
  • CAL Check Standards
  • Checker HC Colorimeters
  • COD Meters
  • Dissolved Oxygen
  • ISE Meters
  • Lab Supply
  • Multiparameter Meters
  • pH Meters
  • Photometers
  • Resistivity
  • Testers
  • Thermometers
  • Titrators
  • Turbidity Meters

EC/TDS Testers

Soil Test™ Direct Soil EC Tester - HI98331

Soil Test™ Direct Soil EC Tester - HI98331

The HI98331 features a stainless steel penetration electrode that provides the ability to take direct measurements in soil. When calibration is needed, simply submerge the electrode tip into calibration solution and and enter calibration mode for automatic 1 point calibration.

Electrolytic conductivity, abbreviated as EC, is a measurement made in which electrical charges of particles in a medium are moved under the influence of a potential difference. EC is a measure of concentration, however, it is non-specic for ion type. An ion is a charged particle present in the solution that contributes to the current flow. Ions are formed when a salt such as sodium chloride is dissolved in water to form particles having electrical charges. Sodium chloride, separates into Na+ and Cl

Electrical conductance, the ability of a substance to conduct an electrical current is the reciprocal of electrical resistance. “Conductance” and “Resistance” depend on the geometrical dimensions of the substance being measured. Conductivity and resistivity are “normalized” terms that are used to denote a bulk intrinsic property of a substance. This is the measurement a standardized EC probe on a Conductivity or resistivity meter provides. Conductivity measurements can be used to provide additional industry specific measurements; TDS, Salinity and USP compliant conductivity. Many of Hanna’s meters provide these measurements also.

Features at-a-glance:

One-point calibration

  • Automatic calibration to 1413 µS/cm conductivity standard

Automatic Temperature Compensation (ATC)

  • Samples automatically compensated for temperature variations
  • Uses a fixed 2%/℃ temperature correction coefficient

Stainless steel penetration electrode

  • Allows for direct measurement in soil

Marine Salinity Waterproof Tester - HI98319

Marine Salinity Waterproof Tester - HI98319

Salinity measurements calculated from a conductivity measurement using known tables

Choice of measurement units displayed in parts per thousand (ppt), Practical Salinity Units (PSU), or specific gravity (S.G.)

Automatic Temperature Compensation (ATC), displays temperature in ℃ or ℉

Amperometric graphite sensor reduces polarization effects and does not oxidize

Large LCD displays stability indicator, low-battery indicator, and calibration tags

Dedicated calibration button with automatic recognition of the 35.00 ppt calibration solution in calibration mode

Supplied complete with meter and calibration sachets in a durable plastic storage case.

GroLine Waterproof EC/TDS Tester - HI98318

GroLine Waterproof EC/TDS Tester - HI98318

The GroLine Waterproof EC/TDS Tester is made specifically for hydroponics, provides a simple, inexpensive solution to measure fertilizer concentration in a nutrient solution.

The HI98318 EC/TDS tester has a graphite sensor that reduces the polarization effect common with amperometric testers that use two stainless steel pins.

Automatic calibration is achieved easily. Simply submerge the sensor in calibration solution and the meter will automatically detect the calibration standard (5.00 mS/cm in Quick Cal mode or 1.41 mS/cm in standard calibration mode). Temperature is automatically compensated for with the integrated temperature sensor.

Features at-a-glance

  • Waterproof
  • Fast Automatic Temperature Compensation with exposed temperature probe
  • Graphite sensors that reduce polarization effects
  • 0.5 (500 ppm) and 0.7 (700 ppm) selectable EC to TDS conversion factors
  • Single point automatic calibration using Quick Cal standard or 1.41 mS/cm in standard calibration mode
  • 250 hour battery life

Pool Line EC/TDS Tester (High Range) - HI983124

Pool Line EC/TDS Tester (High Range) - HI983124

User selected EC to TDS conversion factor from 0.45 or 1.00

User selected temperature compensation coefficient β (BETA)

Replaceable, amperometric, graphite EC/TDS sensor

Automatic Temperature Compensation (ATC) displays temperature in ℃ or ℉

Large LCD displays stability indicator, low battery indicator, and calibration tags

Battery Error Prevention System (BEPS) with battery % level displayed at startup

Auto-off feature automatically shuts off the meter after 8 minutes of non-use to maximize battery life

DiST® 6 EC/TDS/Temperature Tester (0.00 to 20.00 mS/cm) - HI98312

When the original DiST® (Dissolved Solids Tester) was first introduced, conductivity and total dissolved solids measurements became easy and affordable. The DiST’s ease of use, in combination with it’s affordability, made it the standard in EC and TDS measurement. Hanna continues the standard in EC and TDS testing with the DiST®6.

These testers include features such as:

  • a replaceable graphite electrode
  • adjustable TDS ratio
  • ℃ or ℉ measurements
  • Automatic Temperature Compensation (ATC) with adjustable β
  • battery level indicator
  • stability indicator
  • automatic shut-off
  • automatic calibration.

The graphite conductivity electrode offers greater accuracy by resisting contamination by salt deposits in the sample. All of these features are packed in a floating, waterproof casing. These 3-in-1 testers are unmatched in EC/TDS/ temperature measurements.

Features at-a-glance

  • Waterproof and designed to float
  • Automatic Temperature Compensation
  • HOLD button to freeze readings on the display
  • BEPS Alerts the user of low battery power that could adversely affect readings

DiST® 5 EC/TDS/Temperature Tester (0-3999 µS/cm) - HI98311

When the original DiST® (Dissolved Solids Tester) was first introduced, conductivity and total dissolved solids measurements became easy and affordable. The DiST’s ease of use, in combination with its affordability, made it the standard in EC and TDS measurement. Hanna continues the standard in EC and TDS testing with the DiST®5.

This tester includes features such as a replaceable graphite electrode, adjustable TDS ratio, ℃ or ℉ measurement, Automatic Temperature Compensation (ATC) with adjustable β, battery level indicator, stability indicator, automatic shut-off and automatic calibration.

The graphite conductivity electrode offers greater accuracy by resisting contamination by salt deposits in the sample. All of these features are packed in a floating, waterproof casing. This 3-in-1 tester is unmatched in EC, TDS, and temperature measurements.

 

Features at-a-glance

  • Waterproof and designed to float
  • Automatic Temperature Compensation
  • HOLD button to freeze readings on the display
  • BEPS Alerts the user of low battery power that could adversely affect readings

Ultra Pure Water (UPW) Tester (0.000-1.999 µS/cm) - HI98309

The HI98309 uses a conductometric measurement to determine the purity of water. The HI98309 Ultra Pure Water tester (UPW) enables users to check the purity of water, best suited for electronics and semiconductor industries. This tester is housed in durable casing that provides excellent protection against harsh industrial environments.

The HI98309 features an amperometric graphite electrode that provides better repeatability in measurements, since they do not oxidize. An amperometric measurement of EC is based on Ohm’s Law, I = V/R, where R depends on the distance between two pins and their surface. Oxidation changes both the distance and surface, which will affect accuracy. The non-oxidizing graphite pins are able to provide an optimal surface for accurate, dependable results. When calibration is needed, simply submerge the electrode tip into calibration solution and adjust the trimmer on the side of the tester.

Electrolytic conductivity, abbreviated as EC, is a measurement made in which electrical charges on atomic or larger sized particles in a medium are moved under the influence of a potential difference. EC is a measure of concentration however it is non-specic for ion type. An ion is a charged particle present in the solution that contributes to the current flow. Ions are formed when a salt such as sodium chloride is dissolved in water to form particles having electrical charges. Sodium chloride, separates into Na+ and Cl-. This is a simplified definition for the measurement is affected by many things such as the type of ionic compound(s) dissolved in the water; the ions mobility, the solution viscosity, temperature as well as concentration.

Electrical conductance, the ability of a substance to conduct an electrical current is the reciprocal of electrical resistance. “Conductance” and “Resistance” depend on the geometrical dimensions of the substance being measured. Conductivity and resistivity are “normalized” terms that are used to denote a bulk intrinsic property of a substance. This is the measurement a standardized EC probe on a Conductivity or resistivity meter provides. Conductivity measurements can be used to provide additional industry specific measurements; TDS, Salinity and USP compliant conductivity. Many of Hanna’s meters provide these measurements also.

Features at-a-glance:

Arrives pre-calibrated

  • Factory-calibrated with freshly prepared low-conductivity solutions

Exposed Temperature Probe

  • Fast response to changes in sample temperature

Graphite electrode

  • Reduced polarization effects

Pure Water Tester (0.0 - 99.9 µS/cm) - HI98308

The HI98308 features an amperometric graphite electrode that provides better repeatability in measurements since they do not oxidize. An amperometric measurement of EC is based on Ohm’s Law, I = V/R, where R depends on the distance between two pins and their surface. Oxidation changes both the distance and surface, which will affect accuracy. The non-oxidizing graphite pins are able to provide an optimal surface for accurate, dependable results. When calibration is needed, simply submerge the electrode tip into calibration solution and adjust the trimmer on the side of the tester.

The HI98308 uses a conductometric measurement to determine the purity of water. The HI98308 Pure Water Test (PWT) enables users to check the purity of distilled or demineralized water in laboratory or industrial environments. PWT is suited for fields such as printed circuit board washing, laundry, steam cleaning, checking car battery water and all areas where distilled, demineralized or pure water is used. This tester is housed in durable casing that provides excellent protection against harsh industrial environments.

Electrolytic conductivity, abbreviated as EC, is a measurement made in which electrical charges on atomic or larger sized particles in a medium are moved under the influence of a potential difference. EC is a measure of concentration, however, it is non-specic for ion type. An ion is a charged particle present in the solution that contributes to the current flow. Ions are formed when a salt such as sodium chloride is dissolved in water to form particles having electrical charges. Sodium chloride, separates into Na+ and Cl-. This is a simplified definition as the measurement is affected by many things such as the type of ionic compound(s) dissolved in the water; the ions mobility, the solution viscosity, temperature as well as concentration.

Electrical conductance, the ability of a substance to conduct an electrical current is the reciprocal of electrical resistance. “Conductance” and “Resistance” depend on the geometrical dimensions of the substance being measured. Conductivity and resistivity are “normalized” terms that are used to denote a bulk intrinsic property of a substance. This is the measurement a standardized EC probe on a Conductivity or resistivity meter provides. Conductivity measurements can be used to provide additional industry specific measurements; TDS, Salinity and USP compliant conductivity. Many of Hanna’s meters provide these measurements also.

Features at-a-glance:

One-point calibration

  • Calibrate with 84 µS/cm EC solution using a screwdriver

Exposed Temperature Probe

  • Fast response to changes in sample temperature

Automatic Temperature Compensation (ATC)

  • Samples automatically compensated for temperature variations

Graphite electrode

  • Reduced polarization effects

Pool Line High-Range Combo EC Tester - HI983044

Slim, ergonomic design that fits comfortably in the hand or pocket

Graphite sensor reduces polarization effects and does not oxidize

Amperometric conductivity sensor and temperature measurements in one probe

Automatic Temperature Compensation (ATC), displays temperature in ℃ or ℉

Large LCD displays stability indicator, low-battery indicator, and calibration tags

BEPS (Battery Error Prevention System) with battery % level displayed at startup

Automatic shut-off with three user controlled settings

DiST 4 Waterproof EC Tester (0.00-20.00 mS/cm) - HI98304

The DiST 4 features a large multi-level LCD which displays both conductivity and temperature readings simultaneously. The EC readings are displayed with a 0.01 mS/cm resolution and with an accuracy of ±2% full scale. The EC range of the HI98304 is from 0.00 to 20.00 mS/cm. An exposed temperature sensor allows for rapid automatic temperature compensated conductivity measurements. Temperature can be set to display in ℃ or ℉. The LCD screen has stability and calibration tag indicators. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available.

Conductivity readings are performed by an amperometric graphite electrode that resists oxidation, providing better repeatability in measurements. The use of graphite also reduces the polarization effect common with amperometric testers that use two stainless steel pins.

Calibration is performed by pressing the dedicated calibration button. Once in calibration mode submerge the probe in 12.88 mS/cm calibration standard. When the standard value is recognized and stability reached, the meter will automatically accept and store the calibration value.

Setup options include automatic shut-off timing and temperature unit displayed. Automatic shut-off options are to turn the meter off after 8 minutes, 60 minutes, or disabled. To enter the setup mode the user presses a button located in the battery compartment.

Overview

HI98304 DiST 4 multi-level LCD

 

Multi-Level LCD
The large LCD displays EC, temperature, calibration tag, battery level and instability indicator.

HI98304 DiST 4 Exposed Temperature Probe

 

Exposed Temperature Probe
An exposed temperature probe allows for an extremely fast and stable EC measurement.

HI98304 DiST 4 Two Button Operation

 

Two-Button Operation
Only two buttons for meter operation. One for on/off and one for calibration.

Features/Benefits:

Slim, Ergonomic Design

  • With rounded edges and a case that is only 17 mm (0.7”) thick, the HI98304 is thin and fits comfortably in the hand or pocket.

Large Multi-level LCD

  • The LCD is 29 mm (1.125”) x 20 mm (0.81”) allowing the user to easily read both the pH and temperature simultaneously.

Two-button Operation

  • One for ON/OFF, the other for calibration.

Exposed Temperature Sensor

  • Exposed temperature sensor allows for quick Automatic Temperature Compensated measurements. Temperature can be displayed in either ℃ or ℉.

Graphite Sensor

  • Reduces polarization effects and does not oxidize resulting in a reliable and accurate reading.

Automatic Calibration

  • Automatic calibration at 12.88 mS/cm with a single push of a button.

Stability Indicator

  • A clock tag stability indicator will disappear to alert the user when the reading is stable.

Automatic Shut-off

  • User-selectable time until meter shuts off to conserve battery life. Options are 8 min, 60 min or disabled.

Low Battery Indicator

  • Low battery indicator that is displayed when less than 10% battery life is remaining.

Battery % Level at Startup

  • At start-up, all the LCD segments are displayed for 1 second, then the percent indication of the remaining battery life is displayed.

DiST 3 Waterproof Low-Range EC Tester - HI98303

HI98303 DiST 3 multi-level LCD

 

Multi-Level LCD
The large LCD displays EC, temperature, calibration tag, battery level, and instability indicator.

HI98303 DiST 3 Exposed Temperature Probe

 

Exposed Temperature Probe
An exposed temperature probe allows for an extremely fast and stable EC measurement.

HI98303 DiST 3 Two Button Operation

 

Two-Button Operation
Only two buttons for meter operation. One for on/off and one for calibration.

Slim, ergonomic design that fits comfortably in the hand or pocket

Automatic Temperature Compensation (ATC), displays temperature in ℃ or ℉

Stability indicator confirms the reading has stabilized

Waterproof casing designed to float if dropped in water

Graphite sensor reduces polarization effects and does not oxidize

Automatic calibration at 1413 mS/cm with a single push of a button.

Automatic shut-off with three user settings

Battery Error Prevention System (BEPS) and low-battery Indicator

Pool Line Combo TDS Tester (High Range) - HI983024

Slim, ergonomic design that fits comfortably in the hand or pocket

Large LCD displays stability indicator, low-battery indicator, and calibration tags

Two-button operation

Graphite sensor reduces polarization effects and does not oxidize

Automatic calibration at 1382 ppm (mg/L) with a single push of a button.

Automatic shut-off with user-controlled settings

DiST 2 Waterproof High-Range TDS Tester - HI98302

DiST 2 Waterproof High-Range TDS Tester - HI98302

Overview

HI98302 DiST 2 multi-level LCD

 

Multi-Level LCD
The large LCD displays TDS, temperature, calibration tag, battery level and instability indicator.

HI98302 DiST 2 Exposed Temperature Probe

 

Exposed Temperature Probe
An exposed temperature probe allows for an extremely fast and stable TDS measurement.

HI98302 DiST 2 Two Button Operation

 

Two-Button Operation
Only two buttons for meter operation. One for on/off and one for calibration.

Slim, ergonomic design that fits comfortably in the hand or pocket

Automatic Temperature Compensation (ATC), displays temperature in ℃ or ℉

Waterproof casing designed to floatif dropped in water

Graphite sensor reduces polarization effects and does not oxidize

Automatic calibration at 6.44 ppt with a single push of a button.

Automatic shut-off with three user settings

Battery Error Prevention System (BEPS) and low-battery Indicator

DiST 1 Waterproof TDS Tester (0-2000 ppm) - HI98301

The DiST 1 features a large multi-level LCD which displays both TDS and temperature readings simultaneously. The TDS readings are displayed with a 1 ppm resolution and with an accuracy of ±2% full scale. The TDS range of the HI98301 is from 0 to 2000 ppm. An exposed temperature sensor allows for rapid automatic temperature compensated TDS measurements. Temperature can be set to display in ℃ or ℉. The LCD screen has stability and calibration tag indicators. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available.

TDS readings are performed by an amperometric graphite electrode that resists oxidation, providing better repeatability in measurements. The use of graphite also reduces the polarization effect common with amperometric testers that use two stainless steel pins.

Calibration is performed by pressing the dedicated calibration button. Once in calibration mode submerge the probe in 1382 ppm calibration standard. When the standard value is recognized and stability reached, the meter will automatically accept and store the calibration value.

Setup options include automatic shut-off timing and temperature unit displayed. Automatic shut-off options are to turn the meter off after 8 minutes, 60 minutes, or disabled. To enter the setup mode the user presses a button located in the battery compartment.

 

Overview

HI98301 DiST 1 multi-level LCD

 

Multi-Level LCD
The large LCD displays TDS, temperature, calibration tag, battery level and instability indicator.

HI98301 DiST 1 Exposed Temperature Probe

 

Exposed Temperature Probe
An exposed temperature probe allows for an extremely fast and stable TDS measurement.

HI98301 DiST 1 Two Button Operation

 

Two-Button Operation
Only two buttons for meter operation. One for on/off and one for calibration.

Features/Benefits:

Slim, Ergonomic Design

  • With rounded edges and a case that is only 17 mm (0.7″) thick, the HI98301 is thin and fits comfortably in the hand or pocket.

Large Multi-level LCD

  • The LCD is 29 mm (1.125″) x 20 mm (0.81″) allowing the user to easily read both the pH and temperature simultaneously.

Two-button Operation

  • One for ON/OFF, the other for calibration.

Exposed Temperature Sensor

  • Exposed temperature sensor allows for quick Automatic Temperature Compensated measurements. Temperature can be displayed in either ℃ or ℉.

Graphite Sensor

  • Reduces polarization effects and does not oxidize resulting in a reliable and accurate reading.

Automatic Calibration

  • Automatic calibration at 1382 ppm (mg/L) with a single push of a button.

Stability Indicator

  • A clock tag stability indicator will disappear to alert the user when the reading is stable.

Automatic Shut-off

  • User-selectable time until meter shuts off to conserve battery life. Options are 8 min, 60 min or disabled.

Low Battery Indicator

  • Low battery indicator that is displayed when less than 10% battery life is remaining.

Battery % Level at Startup

  • At start-up, all the LCD segments are displayed for 1 second, then the percent indication of the remaining battery life is displayed.

Pool Line Combo pH/EC/TDS Tester (High Range) - HI981304

Pool Line Combo pH/EC/TDS Tester (High Range) - HI981304

Amperometric EC/TDS sensor, pH electrode, and temperature probe in one meter

High accuracy EC/TDS graphite probe reduces polarization effects and does not oxidize

Selectable EC to TDS conversion factor of 0.45 or 1.0

Automatic Temperature Compensation coefficient β (BETA), displays temperature in ℃ or ℉

Large LCD displays stability indicator, low-battery indicator, and calibration tags

HOLD button for easier measurement recording

Battery Error Prevention System (BEPS) with low battery indicator

GroLine® Nutrient Tester EC/TDS - HI98330

Ideal for hydroponics and agriculture applications, the HI98330 GroLine® Nutrient Tester accurately measures the electrical conductivity (EC) in mS/cm and the total dissolved solids (TDS) conversion in parts per million (ppm) of the nutrients in water.

Suitable for plants that need a higher EC, the tester features an extended range up to 6.0 mS/ cm (EC), 3000 ppm (500 ppm scale), and 4200 ppm (700 ppm scale).

The IP67 waterproof rated and floating casing houses the EC graphite electrodes and temperature sensor, and is suitable for stirring and testing simultaneously.

  • IP67 waterproof and floating design
  • No user calibration needed
  • Auto-on when placed in liquid
  • Auto-off 30 seconds after stable measurement
  • Rugged and doubles as a stirring stick Low battery indicator
  • Readings displayed by 24 brightly lit LED lights
  • Conductivity scales and operational instructions printed on the tester body
  • Easy to clean (detachable crown-shaped cap)

 

Agriculture, hydroponics, irrigation water

HI98330 is supplied with quick reference guide with instrument quality certificate.

Follow by Email
LinkedIn
LinkedIn
Share