Designed specifically for Aquaculture Systems, the YSI 5200A, AquaManager™ Software and AquaViewer II mobile app integrate process control, alarming, and data management into one solution. Simple enough to monitor one tank, powerful enough to manage a full scale farming operation from anywhere in the world. Simultaneously measure dissolved oxygen, pH, conductivity, ORP, salinity and temperature. YSI also offers a multi-channel dissolved oxygen monitor that can be networked with a 5200A or used independently. The 5500Dcan measure dissolved oxygen in up to four tanks/ponds using optical-based sensors which reduce maintenance and calibration requirements over traditional membrane-covered sensors.
Access your facilities water quality data at any time with the AquaViewer App from the App Store or manage your network with AquaManager desktop software.
Feed Smart software manages food delivery based on user-selectable inputs to manage feed delivery based on number of daily feedings, daily feed weights, total biomass and FCRs, along with parameter control based on water quality values. interfaces with most auto feeders.
AquaManager desktop software provides the ability to instantly see an overview of your facility, manage parameter set points, and conveniently manage data to make informed operation decisions. If you’re interested in a continuous monitor for dissolved oxygen, please visit the 5500D (optical dissolved oxygen) or 5400 (galvanic dissolved oxygen) page.
The YSI IOEM and REM expansion modules increase the flexibility and capability of the YSI aquaculture platform when networked with 5200A, 5400 or 5500D instruments. Configure 4 (IOEM-4) or 8 (IOEM-8) analog channels as inputs or outputs for the ability to integrate 3rd party sensors or output from other devices. Outputs can be configured to control pumps, UV systems, analog valves, or send data to SCADA/ PLC systems. REMs(Relay Expansion Module) add relays where needed to control feeders, lighting, heaters, alarming, and more.
Buffer Recognition | Yes |
---|---|
Certifications | RoHS, ETL, IP-65, NEMA 4X, CE, Made in USA, CUL, ULC |
Connectivity / Communications | Ethernet and wireless optional. Output Relays: 4 each 10 amp 115 VAC (5 amp 230 VAC) relays for parameter, control and/or alarm E-mail and/or SMS alarming up to 3 e-mails with Ethernet module or up to 10 e-mails with AquaMana, RS-485 and RS-232 standard |
Data Management | AquaManager™ Software integrates process control, alarming, and data management into one product |
Desktop Software Compatible | AquaManager®, Windows 2000/XP/Vista/Windows 7 operating systems |
Display | Back-lit graphic LCD (320 x 240) with timer, extended temperature range LCD |
Equipment used with | 5562-4, or 20, or 30, AquaManager Desktop Software, 5561-4, 10, 20 |
GLP Compliance | Yes |
Logging Capabilities | Yes |
Measurement Method / Channels | DO, pH, ORP, conductivity, temperature, 2 user-configurable inputs, digital (0 to 1.0 VDC, 0 to 5.0 VDC or 4-20 mA) Timers: 4 timers – 10 events cascading events start/duration 1 feed timer channel (feeder not included), Feed Smart software manages feed |
Memory | 1000 data, 1250 relay/alarm, 1000 entries/change and 500 GLP records, Non-volatile |
Monitoring | Yes |
Multiparameter | Yes |
Operating Temperature | direct outside conditions with NEMA 4X enclosure, -15 to +70°C (5 to 158°F) |
Parameters Measured | Dissolved Oxygen (electrochemical), pH,ORP/Redox, Conductivity, Specific Conductance, Salinity, Total Dissolved Solids (TDS), Temperature |
Power | 12 V DC, mobile live haul or anytime AC power not available |
User Calibratable | Yes |
User Replaceable | Yes |
Warranty | 2-years instrument; 1-year probes and cable |
Waterproof | Yes |
Specification | |
---|---|
Timers | 4 timers – 10 events cascading events start/duration 1 feed timer channel (feeder not included); Feed Smart software manages feed delivery, user-selectable inputs for number of daily feedings, daily feed weights, total biomass, FCRS and parameter control |
Field Upgradeable Software | Yes; flash based |
Height | 6.5 in, 16.5 cm |
Length | 8.5 in, 21.6 cm |
Depth | 4.75 in, 12.1 cm |
Parameter (units) | Range | Accuracy | Resolution |
---|---|---|---|
Dissolved Oxygen* (% saturation) | 0 to 500% | 0 to 200%: ±2% or ±0.2 mg/L, whichever is greater; 200 to 500%: ±6% of reading | 0.1% air saturation |
Dissolved Oxygen* (mg/L, ppm) | 0 to 60 mg/L | 0 to 20 mg/L: ± 0.2 mg/L or ±2% of reading, whichever is greater; 20 to 60 mg/L: ±6% of reading | 0 to 10 mg/L: 0.01 mg/L 10 – 60 mg/L: 0.1 mg/L |
Temperature (°C, °F) | 0 to +45°C (32 to 113°F) | ±0.2°C | 0.1°C |
Conductivity (µS, mS) | 0 to 200 µS; 0 to 2000 µS 0 to 20 mS; 0 to 200 mS | 0 to 100 mS: ±0.5% of range 100 to 200 mS: ±1.0% of reading | 0.1 µS 1 µS 0.01 mS 0.1 mS (range dependent) |
Salinity (ppt) | 0 to 80 ppt (0 to 50 ppt when entered manually) | ±2% or ±0.1 ppt, whichever is greater | 0.1 ppt |
pH (pH units) | 0 to 14 units | ±0.2 units | 0.01 units |
ORP (mV) | -2000 to +2000 mV | ±20 mV | 1 mV |
Cap Membrane Kit 2.00 Mil PE
Cap Membrane Kit 2.00 Mil PE (6 each), includes electrolyte (blue cap)
5578 12-Volt Power Supply, 230 VAC Input
12-Volt Power Supply, 230 VAC Input for 5200A, 5400, and 5500D instruments.
Internal Serial to Ethernet Device Kit
Internal Serial to Ethernet Device Kit. Used with 5200A, 5400 and 5500D Instruments.
5579 12-Volt Power Supply, 115 VAC Input
12-Volt Power Supply, 115 VAC Input for 5200A, 5400, and 5500D instruments.
AquaManager® Software
AquaManager Software, Single and network use for 5200A, 5400, and 5500D instruments.
5561 Polarographic DO and Temperature Cable
Polarographic DO and Temperature Cable for the 5200A Instrument
Designed specifically for aquaculture systems, the YSI 5500D continuous monitor for dissolved oxygen and AquaManager® Software can be used to integrate process control, feeding, alarming and data management into one product or can be used to simply monitor one tank. With YSI’s ODO® optical dissolved oxygen technology you’ll benefit from reduced costs, less maintenance and better data. The ODO sensors require no membrane changes, no electrode cleaning, no stirring requirement and less frequent calibrations.
Access your facilities water quality data at any time with the AquaViewer App from the App Store or manage your network with AquaManager desktop software.
•MultiDO monitor using optical DO technology; 1-4 DO probe inputs depending on model
•Ethernet TCP/IP or wireless communications – optional.
•Event logging records calibrations, high and low conditions, and more.
•Conditional feed timer with Feed Smart software included.
•Networking capability up to 32 instruments per communications port or integration with 5200As and 5400s.
•Graphic interface function for quick, reliable system status with the use of AquaManager software.
•Plug-and-play…easy to install, setup and maintain; no need to hire consultants.
•Flexible control software.
•E-mail and SMS alarming.
•AquaViewer app available for easy access to data at any time.
The standard conditional feed timer, Feed Smart, manages food delivery based on user’s preset criteria. Manage feed delivery based on user-selectable inputs for the number of daily feedings, daily feed weights, total biomass and feed conversion ratios (FCRs), along with parameter control based on water quality values. Interfaces with most auto feeders.
Optional AquaManager® desktop software allows you to view, configure, or setup instruments from the convenience of one central location. Instantly see an overview of your facility, manage parameter set points, and conveniently manage data to make informed operational decisions. The facility mapping feature provides an immediate overview of all ponds or tanks indicating their current state.
The YSI IOEM and REM expansion modules increase the flexibility and capability of the YSI aquaculture platform when networked with 5200A, 5400 or 5500D instruments. Configure 4 (IOEM-4) or 8 (IOEM-8) analog channels as inputs or outputs for the ability to integrate 3rd party sensors or output from other devices. Outputs can be configured to control pumps, UV systems, analog valves, or send data to SCADA/ PLC systems. REMs (Relay Expansion Module) add relays where needed to control feeders, lighting, heaters, alarming, and more.
Buffer Recognition | Yes |
---|---|
Certifications | NEMA 4X, IP-65, ETL, Made in USA, RoHS, ULC, CE, CUL |
Connectivity / Communications | RS485 and RS232 standard, Ethernet and wireless optional |
Data Management | AquaManager™ Software integrates process control, alarming, and data management into one product |
Desktop Software Compatible | AquaManager®, Windows 2000/XP/Vista/Windows 7 operating systems |
Display | Back-lit graphic LCD (320 x 240) with timer, extended temperature range LCD |
Equipment used with | 50-, 30-, 40-, 10, 10-, 60- or 100-meter cable with optical DO probe/Temp 626320 Sensor Cap (included with initial cable/probe purchase) 5402 Serial to Ethernet Module 5285 RS232 Opto isolator 6505 W, 60 or 100 1-, 50, 30, 626250-1, 20, 20-, 40, 4, 4- |
GLP Compliance | Yes |
Logging Capabilities | Yes |
Measurement Method / Channels | 1-4 DO probe inputs depending on model 4 user-configurable inputs for temp or (digital 0 to 1.0 VDC, etc. (transmitter may be required) 2 user-configurable inputs (digital 0 to 1.0 VDC, 0 to 5.0 V, ORP, pH, 0 to 5.0 VDC or 4-20 mA) DO, TGP, photo period |
Memory | 2000 data, 1250 relay/alarm, 1000 entries/change and 500 GLP records, Non-volatile |
Monitoring | Yes |
Operating Temperature | direct outside conditions with NEMA 4X enclosure, -15 to +70°C (5 to 158°F) |
Parameters Measured | Dissolved Oxygen % Saturation, Dissolved Oxygen mg/L, Temperature (optional) |
Power | automatically switches to 12 VDC back-up with alarm if primary voltage drops, 100-240 VAC |
User Calibratable | Yes |
User Replaceable | Yes |
Warranty | 2-years instrument, probes and cable; 1-year sensor cap (actual sensor cap life may be longer) |
Waterproof | Yes |
Specification | |
---|---|
Timers | 4 timers – 10 events cascading events start/duration 4 feed timers (feeders not included); Feed Smart software manages feed delivery, user-selectable inputs for number of daily feedings, daily feed weights, total biomass, FCRS and parameter control |
Inputs | 1-4 DO probe inputs depending on model 4 user-configurable inputs for temp or (digital 0 to 1.0 VDC, 0 to 5.0 VDC or 4-20 mA) DO, pH, TGP, ORP, photo period, etc. (transmitter may be required) 2 user-configurable inputs (digital 0 to 1.0 VDC, 0 to 5.0 VDC or 4-20 mA) DO, pH, TGP, ORP, photo period, etc. (transmitter may be required) |
Output Relays | 8 each 10 amp 115 VAC (5 amp 230 VAC) relays for parameter, control and/or alarm E-mail and/or SMS alarming up to 3 e-mails with Ethernet module or up to 10 e-mails with AquaManager |
Field Upgradeable Software | Yes; flash based |
Height | 6.5 in, 16.5 cm |
Length | 8.5 in, 21.6 cm |
Depth | 4.75 in, 12.1 cm |
Optical Sensor – Diameter | 0.95 in, 2.4 cm |
Optical Sensor – Length | 7.5 in, 19 cm |
Parameter (units) | Range | Accuracy | Resolution |
---|---|---|---|
Dissolved Oxygen* (% saturation) | 0 to 500% | 0 to 200%: ±1% of reading or ±1% air sat, whichever is greater; 200 to 500%: ±10% of reading | 0.1% air saturation |
Dissolved Oxygen* (mg/L) | 0 to 50 mg/L | 0 to 20 mg/L: ± 0.1 mg/L or ±1% of reading, whichever is greater; 20 to 50 mg/L: ±10% of reading | 0.01 mg/L or 0.1 mg/L (auto-scaling) |
Temperature (°C, °F) | 0 to +45°C (32 to 113°F) | ±0.2°C | 0.1°C |
Replacement ODO Sensor Cap Kit
Replacement ODO Sensor Cap Kit
ODO Sensors for Monitoring and Control
Optical Dissolved Oxygen and Temperature Sensor for Aquaculture Continuous Monitoring and Control
Engineered specifically for aquaculture systems, the YSI 5400 and AquaManager® Software integrate process control, alarming, and data management into one product. Simple enough to monitor one tank, powerful enough to manage a full scale farming operation from anywhere in the world. Simultaneously measure dissolved oxygen in multiple tanks or ponds.
Access your facilities water quality data at any time with the AquaViewer App from the App Store or manage your network with AquaManager desktop software.
Feed Smart software manages food delivery based on user-selectable inputs to manage feed delivery based on number of daily feedings, daily feed weights, total biomass and FCRs, along with parameter control based on water quality values. interfaces with most auto feeders.
AquaManager desktop software provides the ability to instantly see an overview of your facility, manage parameter set points, and conveniently manage data to make informed operation decisions.
If you’re interested in a continuous monitor for multiple parameters, please visit the 5200A page or if you’d prefer optical dissolved oxygen please visit the 5500D page.
The YSI IOEM and REM expansion modules increase the flexibility and capability of the YSI aquaculture platform when networked with 5200A, 5400 or 5500D instruments. Configure 4 (IOEM-4) or 8 (IOEM-8) analog channels as inputs or outputs for the ability to integrate 3rd party sensors or output from other devices. Outputs can be configured to control pumps, UV systems, analog valves, or send data to SCADA/ PLC systems. REMs (Relay Expansion Module) add relays where needed to control feeders, lighting, heaters, alarming, and more.
Buffer Recognition | Yes |
---|---|
Certifications | CE, NEMA 4X, Made in USA, CUL, ETL, RoHS, ULC, IP-65 |
Connectivity / Communications | RS-485 and RS-232 standard, Ethernet and wireless optional |
Data Management | AquaManager™ Software integrates process control, alarming, and data management into one product |
Desktop Software Compatible | AquaManager®, Windows 2000/XP/Vista/Windows 7 operating systems |
Display | Back-lit graphic LCD (320 x 240) with timer, extended temperature range LCD |
Equipment used with | AquaManager Desktop Software, 5420-4, or 30, 5421-4, 20, 20 or 30, 10 |
GLP Compliance | Yes |
Logging Capabilities | Yes |
Measurement Method / Channels | pH, 0 to 5.0 VDC or 4-20 mA) 8 each 10 amp 115 VAC (5 amp 230 VAC) relay, 4 DO probe inputs 4 user-configurable inputs for temp (0 to 1.0 VDC, digital (0 to 1.0 VDC, photo period, etc. 2 user-configurable inputs, TGP, ORP, 0 to 5.0 VDC or 4-20 mA) or DO |
Memory | Non-volatile, 1000 data, 1250 relay/alarm, 1000 entries/change and 500 GLP records |
Monitoring | Yes |
Operating Temperature | -15 to +70°C (5 to 158°F), direct outside conditions with NEMA 4X enclosure |
Parameters Measured | Dissolved Oxygen % Saturation, Dissolved Oxygen mg/L, Temperature (optional) |
Power | 12 V DC, mobile live haul or anytime AC power not available |
User Calibratable | Yes |
User Replaceable | Yes |
Warranty | 2-years instrument; 1-year probes and cable |
Waterproof | Yes |
Specification | |
---|---|
Timers | 4 timers – 10 events cascading events start/duration 1 feed timer channel (feeder not included); Feed Smart software manages feed delivery, user-selectable inputs for number of daily feedings, daily feed weights, total biomass, FCRS and parameter control |
Output Relays | 8 each 10 amp 115 VAC (5 amp 230 VAC) relays for parameter, control and/or alarm E-mail and/or SMS alarming up to 3 e-mails with Ethernet module or up to 10 e-mails with AquaManager |
Field Upgradeable Software | Yes; flash based |
Height | 6.5 in, 16.5 cm |
Length | 8.5 in, 21.6 cm |
Depth | 4.75 in, 12.1 cm |
Parameter (units) | Range | Accuracy | Resolution |
---|---|---|---|
Dissolved Oxygen* (% saturation) | 0 to 500% | 0 to 200%: ±2% or ±0.2 mg/L, whichever is greater; 200 to 500%: ±6% of reading | 0.1% air saturation |
Dissolved Oxygen* (mg/L, ppm) | 0 to 60 mg/L | 0 to 20 mg/L: ± 0.2 mg/L or ±2% of reading, whichever is greater; 20 to 60 mg/L: ±6% of reading | 0 to 10 mg/L: 0.01 mg/L 10 – 60 mg/L: 0.1 mg/L |
Temperature (°C, °F) | 0 to +45°C (32 to 113°F) | ±0.2°C | 0.1°C |
5420 Galvanic DO Cable
Galvanic DO Cable in mg/l for the 5400 Monitor
5578 12-Volt Power Supply, 230 VAC Input
12-Volt Power Supply, 230 VAC Input for 5200A, 5400, and 5500D instruments.
5579 12-Volt Power Supply, 115 VAC Input
12-Volt Power Supply, 115 VAC Input for 5200A, 5400, and 5500D instruments.
AquaManager® Software
AquaManager Software, Single and network use for 5200A, 5400, and 5500D instruments.
Engineered specifically for aquaculture applications, the optical dissolved oxygen sensor can be used with the 5500D MultiDO monitor for process control to ensure adequate oxygen levels for your livestock or for improved energy efficiency. With YSI’s ODO® optical dissolved oxygen technology you’ll benefit from reduced costs, less maintenance and better data. The ODO sensors require no membrane changes, no electrode cleaning, no stirring for accurate data and less frequent calibrations.
You can also incorporate the DO sensor directly with your PLC via the RS485 communication. Additional inputs for barometric pressure and salinity are used to accurately calculate the DO % and mg/L.
Features:
Applications:
Accuracy | 0 to 200% air saturation ±1% of the reading or ±1% air saturation, whichever is greater; 200 to 500% air saturation ±10% of the reading; 0 to 20 mg/L ±0.1 mg/L or ±1% of reading, whichever is greater; 20 to 50 mg/L ±10% of the reading; ±0.2 ºC |
---|---|
Certifications | CE, RoHS, WEEE, C-Tick, VCCI, IP-67, Made in USA |
Connectivity / Communications | RS485, proprietary communication |
Equipment used with | 5500D |
Measurement Range | 0 to 500% air saturation; 0 to 50 mg/L; -5 to 70 oC (23 to 158 oF) |
Parameters Measured | Dissolved Oxygen (optical), Temperature |
Power | 6.3 VDC at 10-20 mA |
Resolution | 0.1% air saturation; 0.01 or 0.1 mg/L (auto scaling); 0.1 ºC |
Response Time | 90% of reading in 25 seconds; 95% of reading in 45 seconds (typical response times with no stirring; sample movement will improve typical response times) |
Size | Length: 19 cm (7.5 in); Diameter 2.4 cm (0.95 in) |
Storage Temperature | -20 to 70ºC (-4 to 158ºF) |
Warranty | 2-years cable and probe; 1-year sensor cap (actual sensor cap life may be longer) |
The 5562 probe and cable assembly is multiparameter and allows for the measurement of temperature, dissolved oxygen (polarograhic sensor), conductivity, and has a port for either a pH or pH/ORP sensor (must be ordered separately). It is available in lengths of 4 m, 10 m, and 20 m. . This cable is compatible with the 5200 and 5200A Multiparameter Monitoring and Control Instrument
The 5562 probe and cable assembly includes a 559 polarographic sensor, a 5560 combination conductivity/temperature sensor and a 5204 DO Membrane Kit (2 mil, Teflon). Please order the 5564 pH/ORP sensor separately
Equipment used with | 5200A Multiparameter Monitoring and Control Instrument |
---|---|
Parameters Measured | Dissolved Oxygen, Temperature, Conductivity |