Available in quartz or PFA to suit your analysis requirements, these Thermo Scientific™ Cyclonic Spray Chambers are for use with the Thermo Scientific™ iCAP™ Q ICP-MS system. Low-volume, baffled cyclonic spray chambers efficiently filter out larger aerosol droplets for improved plasma stability
For Use With (Equipment) | iCAP Q ICP-MS System |
Type | Cyclonic Spray Chamber |
Description | PFA |
Unit Size | Each |
1320260
Bring the power of the first-ever combination of high-resolution gas chromatography (GC) and high-resolution/accurate-mass (HRAM) Orbitrap mass spectrometry to your laboratory. The Thermo Scientific™ Q Exactive™ GC Orbitrap™ GC-MS/MS system provides comprehensive characterization of samples in a single analysis for the highest confidence in compound discovery, identification, and quantitation. This system offers the quantitative power of a GC triple quadrupole MS combined with the high precision, full-scan HRAM capabilities only available in combination with Thermo Scientific™ Orbitrap™ technology
Mass Range | 30 to 3,000 <em>m/z</em> |
Type | Orbitrap GC-MS/MS System |
Dynamic Range | Quantitative: >106, In-Spectrum: >5000:1 |
MS Scan Power | up to 18 Hz at resolution setting of 12,500 at m/z 272 |
Mass Accuracy | Internal: <1 ppm RMS; External: <3ppm RMS |
Sensitivity | Parts-per-trillion Concentration |
Resolution | 100,000 @ <em>m/z</em> 272 |
Description | Q Exactive GC Orbitrap GC-MS/MS |
0725500
Obtain high confidence insights for very complex molecules with the Thermo Scientific™ Orbitrap Eclipse™ Tribrid™ mass spectrometer. It combines industry-leading versatility and usability with the exceptional performance afforded by its built-in intelligence and revolutionary Thermo Scientific™ Tribrid™ architecture to deliver an instrument designed to address the most difficult analytical challenges. This newest Tribrid platform includes Advanced Ion Management Technology (AIM+) with the new QR5 segmented quadrupole mass filter, Real-Time Search, Enhanced Vacuum Technology, optional Proton Transfer Charge Reduction (PTCR), and optional High Mass Range MSn (HMRn) mode. Collectively, these features make this instrument uniquely suited for accurate and high-throughput full-proteome quantitation, characterization of complex mixtures of protein or small molecule-based pharmaceuticals, and deciphering higher-order protein structures. The Orbitrap Eclipse Tribrid MS makes it easy to tackle these difficult analyses and collect the high-quality data required to drive the right decisions, pushing your science beyond today’s discovery.
Mass Range | Standard mass range 50 to 2000 m/z; mid-mass range 200 to 6000 m/z; and optional HMRn mass range 500 to 8000 m/z |
Type | Orbitrap LC-MS |
Dynamic Range | > 5000 with a single OTMS spectrum |
Mass Accuracy | Orbitrap mass accuracy: < 3 ppm RMS using external calibration < 1 ppm RMS using internal calibration |
Polarity Switching | One Full Cycle in < 1.1 sec |
Resolution | 7500 to 500,000 (FWHM) at m/z 200 |
Description | Orbitrap Eclipse Tribrid MS – Proton Transfer Charge Reduction Ready (PTCR) |
Dimensions (D x W x H) | 30 x 50 x 28 in. (77 x 127 x 70cm) |
Scan Rates | OTMSn up to 40 Hz ITMSn up to 45 Hz |
Weight (Metric) | 180 kg (400 lbs) |
FSN04-10003
Perform routine isotope analysis or explore novel isotopes in unknown materials using the Thermo Scientific Neoma multicollector ICP-MS (MC-ICP-MS). This ICP-MS system builds on our multicollector technology to deliver all the advantages of high-precision isotope ratio analysis, with none of the limitations. It includes state-of-the art software and hardware, features flexible and sensitive detector technology, a sensitive ion source and excellent mass resolving power, enabling challenging isotope analyses.
Description | Neoma MC-ICP-MS |
Type | MC-ICP-MS |
Includes | System only |
Unit Size | Each |
IQLAAMGAATFARHMBLH
Description | MSQ Plus |
Gas Requirements | Supply of High-Purity (>99%) Nitrogen Capable of Supplying 12 L/Min (at 75 Psi (5 Bar)) |
Mass Range | 17 to 2000 m/z with Unit Mass Resolution |
MS Scan Power | up to 12000 amu/sec |
Polarity Switching | Fast |
Sensitivity | Positive Ion ESI-50 pg Injection (10 µL x 5 pg/µL) of Erythromycin: 1000:1 S/N, Negative Ion ESI-20 pg Loop Injection (10 µL x 2 pg/µL) of p-Nitrophenol: 500:1 S/N ,Positive Ion APCI-50 pg Injection |
Height (English) | 21 in. |
Height (Metric) | 530 mm |
Width (English) | 12 in. |
Width (Metric) | 300 mm |
Voltage | 230 V |
Weight (Metric) | 60 kg |
Weight (English) | 132 lb. |
Item Description | MSQ Plus Single Quadrupole Mass Spectrometer |
IQLAAAGAAWFAFIMALO
Meet your most challenging biological research objectives using the Thermo Scientific™ Orbitrap Fusion™ Tribrid™ Mass Spectrometer. This instrument combines the best of quadrupole, ion trap and Orbitrap mass analysis in a revolutionary Tribrid architecture to provide unprecedented depth of analysis and ease of use. Innovative software and instrument design let you concentrate on your science rather than method development and instrument operation
Mass Range | 50 to 6000 m/z |
Type | Orbitrap LC-MS |
Dynamic Range | >5000:1 |
Mass Accuracy | Internal: <1-ppm RMS External: <3-ppm RMS |
Polarity Switching | One Full Cycle in <1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 30,000)) |
Sensitivity | MS/MS: 100 fg Reserpine on Column S/N 100:1; test requires HESI II probe |
Resolution | 450,000 |
Item Description | Orbitrap Fusion Tribrid Mass Spectrometer |
Description | Orbitrap Fusion Tribrid Mass Spectrometer |
Scan Rates | MSn for n=1 Through 10 |
Weight (Metric) | 318 kg (700 lbs) with table but without data system, vacuum rough pumps, and optional items |
IQLAAEGAAPFADBMBCX
By combining the separation power of gas chromatography with IRMS, the Thermo Scientific™ GC IsoLink II™ IRMS System provides a significant step forward in the performance of compound analysis. This preparation device, when coupled with the Thermo Scientific™ ConFlo IV universal continuous flow interface and the Thermo Scientific™ Delta Q™ IRMS, provides a seamless solution that meets the analytical challenges of today’s rapidly expanding world of isotope applications.
Description | GC IsoLink II IRMS System |
Unit Size | Each |
IQLAAEGAATFAETMATA
Obtain high sensitivity full scan MS along with in-depth MSn (CRM) capabilities with the Thermo Scientific™ LTQ XL™ linear ion trap mass spectrometer. A single quadrupole offers Selected Ion Monitoring. A triple quadrupole adds Selected Reaction Monitoring. A linear ion trap goes further by enabling Consecutive Reaction Monitoring where a selected ion is fragmented into a product ion and the resulting product ion further fragmented in additional consecutive steps. Each additional fragmentation step makes compound identification more certain and facilitates structural characterization.
Mass Range | 15 to 200 m/z; 50 – 2000 m/z; 200 – 4000 m/z |
MS Scan Power | MSn for n = 1 through 10 |
Polarity Switching | <100 msec between positive and negative MS Scan Power |
Resolution | 0.15 FWHM; 0.3 FWHM; 0.45 FWHM; 0.7 FWHM; 3 FWHM |
Amperage | 15 A |
Hertz | 50/60 Hz |
Voltage | 230 VAC |
Weight (Metric) | 120 kg |
Description | LTQ XL Linear Ion Trap Mass Spectrometer |
IQLAAEGAAVFACZMAIK
Adding mass spectrometry (MS) to your liquid chromatography (LC) analyses gives you access to the valuable data that only MS can provide. The new, easy-to-use ISQ™ EM Single Quadrupole Mass Spectrometer seamlessly integrates with LC systems for reliable, robust, and easy LC-MS routine analysis with an extended mass range for more flexibility. Detect and quantify a variety of analytes by choosing to use either heated electrospray ionization (HESI) or atmospheric pressure chemical ionization (APCI). Integrated software allows both novices and experts to quickly master MS to gain more insights from every sample
Description | ISQ EM single quadrupole mass spectrometer for liquid chromatography with extended mass range, dual HESI/APCI source |
Gas Requirements | >99% purity nitrogen capable of supplying 30L/min at 110 psig |
Mass Range | 10 to 2000 m/z with Unit Mass Resolution |
MS Scan Power | up to 20,000 Da/s |
Polarity Switching | Yes, 25 ms for HESI and APCI |
Sensitivity | HESI Positive Mode – 10 pg Reserpine, 400:1 RMS, at 400µL/min (Selected ion monitoring of m/z 609.3) HESI Negative Mode – 20 pg p-Nitrophenol, 500:1 RMS, at 400µL/min (Selected ion monitoring of m/z 138.0) APCI Positive Mode -10 pg Reserpine, 1000:1 RMS, at 400µL/min (Selected ion monitoring of m/z 609.3) APCI Negative Mode – 20 pg p-Nitrophenol, 80:1 RMS, at 900µL/min (Selected ion monitoring of m/z 138.0) |
Height (Metric) | 52 cm |
Width (Metric) | 42 cm |
Depth (Metric) | 91 cm |
Voltage | 100-240 VAC, 50/60 Hz |
Weight (Metric) | 71 kg |
Weight (English) | 157 lb. |
ISQEM-ESI-APCI
Easily couple ion chromatography (IC) or liquid chromatography (LC) systems to Thermo Scientific™ iCAP™ Q/Qnova Series ICP-MS systems with this handy Thermo Scientific™ IC/LC Connector Kit. The kit contains a specially designed nebulizer and all the necessary tubing to simply and efficiently configure a chromatographic column with an iCAP Q/Qnova Series ICP-MS system for trace elemental speciation applications
For Use With (Equipment) | iCAP Q/Qnova Series ICP-MS Systems |
Type | IC/LC Connector Kit |
Description | IC/LC Connector Kit for iCAP Q/Qnova Series ICP-MS systems |
Unit Size | Each |
1335350
Maintain the advanced performance of the Thermo Scientific™ ELEMENT™ GD GD-MS and ELEMENT Series HR-ICP-MS analyzers with the periodic replacement of the Thermo Scientific™ Secondary Electron Multiplier (SEM) Detector
For Use With (Equipment) | ELEMENT GD GD-MS Instrument and ELEMENT Series HR-ICP-MS |
Type | SEM Detector |
Item Description | Secondary Electron Multiplier (SEM) Detector |
Description | SEM Detector |
Unit Size | Each |
1152700
The power of multi-award winning Orbitrap™ GC-MS technology has so far allowed research scientists to break new ground in gaining a broader and deeper understanding of their samples through the use of high-resolution, accurate-mass (HRAM) analysis. The introduction of the Thermo Scientific™ Exactive™ GC Orbitrap™ GC-MS system brings that power into the routine environment for the first time. This system allows scientists working in fields like food safety, environmental, industrial, forensics and anti-doping to revolutionize their workflows by taking their analytical capability to the next level.
Mass Range | 30 to 3,000 <em>m/z</em> |
Type | Orbitrap GC-MS/MS System |
Dynamic Range | Quantitative: >106, In-Spectrum: >5000:1 |
MS Scan Power | up to 18 Hz at resolution setting of 12,500 at m/z 272 |
Mass Accuracy | Internal: <1 ppm RMS; External: <3ppm RMS |
Sensitivity | Parts-per-trillion Concentration |
Resolution | 50,000 (at m/z 272) |
Description | Exactive GC Orbitrap GC-MS System |
0725510
Description | Ultra high resolution IRMS |
Unit Size | Each |
Make the laboratory environment more comfortable for your users with this optional Thermo Scientific™ Noise Reduction Cover for the Thermo Scientific™ iCAP™ Q/Qnova Series ICP-MS rotary pump.
For Use With (Equipment) | iCAP Q/Qnova Series ICP-MS Systems |
Type | Noise Reduction Cover |
Description | Noise Reduction Cover for iCAP Q/Qnova Series ICP-MS systems |
Unit Size | Each |
1245180
Enable fast cleanup of complex matrices for accelerated online sample preparation, lower your laboratory costs, and improve data quality using Thermo Scientific Transcend TLX Systems with Turboflow technology. These systems use a combination of chromatographic techniques for online sample cleanup to improve LC-MS detection, reduce manual work, and provide higher productivity while the systems’ additional channel capabilities improve throughput by up to 400%
Description | Transcend TLX-4 System |
Unit Size | Each |
60500-60203
Perform routine measurements for quality control or teaching in the chemistry classroom with rugged Thermo Scientific™ GENESYS™ 50 UV-Visible and GENESYS 40 Vis Spectrophotometers. Offered in a single cell configuration, these instruments are designed with a sloping surface to shed spills and a washable sampling compartment for easy clean up. A 7-inch touchscreen interface, local control software (no PC needed) and optional Wi-Fi networking make the GENESYS 50 UV-Vis or GENESYS 40 Vis Spectrophotometer the ideal choice for daily sampling purposes
Connections | Single USB-A supports flash memory devices for method and data storage Duplex USB-A on side supports connection to a Windows™ computer running optional remote control software, keyboard, mouse Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, available Print via USB, Ethernet or Wi-Fi USB adaptor available |
Detector Type | Dual Silicon Photodiodes |
Display | 7-inch color touchscreen, fixed, high definition, 800 × 1280 pixels |
Photometric Accuracy Instrument | ±0.002A at 0.5A±0.004A at 1.0A±0.008A at 2.0A |
Printer | Snap-on printer available |
Wavelength Accuracy | ±0.5 nm |
Wavelength Range | 190 nm – 1100 nm |
Applications | Sample Concentration |
Baseline Flatness | ±0.002A |
Compartments | Accessible from top, front or side Able to accommodate cells up to 100mm cells Available accessory for test tubes up to 25 mm diameter and 150 mm height Removable, washable sample compartment liner with magnetic placement and hold-down |
Description | GENESYS 50 UV-Vis Spectrophotometer with UK Power Cable |
Dimensions (L x W x H) | 35.5 x 38.5 x 19.5 cm |
Drift | (At 500 nm after 1 hour warmup) <0.0005A/Hr |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100–240 volts, 50–60 Hz. |
Keypad | Touchscreen |
Lamp | Xenon Flash Lamp (>5 years typical, 3 years guaranteed) |
Noise | (RMS at 500 nm 60 consecutive measurements) ≤0.00020A at 0A at 260 and 500 nm ≤0.00030A at 1A at 260 and 500 nm ≤0.00040A at 2A at 260 and 500 nm |
Optical Design | Dual beam |
Photometric Display | -3A to +5A |
Photometric Range | –2A to +3.5A |
Photometric Repeatability | ±0.001A at 1A measured at 1.0A at 546 nm |
Spectral Bandwidth | 2 nm |
Stray Light | < 1.0%T 198 nm (KCl) , <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO2) |
Wavelength Data Interval | 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
Wavelength Repeatability | < ±0.2 nm |
Wavelength Scan Speed | Slow, medium and fast – up to 1600 nm/min |
840-298400
Perform high throughput quantitative UV-Vis measurements where a double beam is required as a reference cell position with the Thermo Scientific™ GENESYS™ 180 UV-Visible Spectrophotometer. Optimized for usability and performance, this platform features a high-resolution color touchscreen, optional Wi-Fi networking, and a rugged design built for repetitive, heavy use environments. Regarded worldwide for reliability, accuracy and reproducibility, GENESYS spectrophotometers meet today’s expectations for advanced technology in a compact, robust package
Connections | Single USB-A supports flash memory devices for method and data storage Duplex USB-A on side supports connection to a Windows™ computer running optional remote control software, keyboard, mouse Export data to network or PC via USB, Ethernet, or Wi-Fi USB adaptor, available Print via USB, Ethernet or Wi-Fi USB adaptor available |
Detector Type | Dual Silicon Photodiodes |
Display | 7-in. color touchscreen, tiltable, high definition, 800 × 1280 pixels |
Photometric Accuracy Instrument | ±0.002A at 0.5A ±0.004A at 1.0A ±0.008A at 2.0A |
Printer | Snap-on printer available |
Wavelength Accuracy | ±0.5 nm |
Wavelength Range | 190 nm – 1100 nm |
Applications | Sample Concentration |
Baseline Flatness | ±0.002A |
Compartments | 8-position cell changer (standard) Also accommodates (optional): 4-position cell changer (long path cells) Peltier thermostatted cell holder (20-60 °C) Sipper accessory Fiber optic probe coupler |
Description | GENESYS 180 UV-Vis Spectrophotometer with UK Power Cable |
Dimensions (L x W x H) | 35.5 x 38.5 x 19.5 cm |
Drift | (At 500 nm after 1 hour warmup) <0.0005A/Hr |
Electrical Requirements | External AC to DC converter. Voltage and Frequency (Hz) selected automatically, 100–240 volts, 50–60 Hz. |
Keypad | Touchscreen |
Lamp | Xenon Flash Lamp (>5 years typical, 3 years guaranteed) |
Noise | (RMS at 500 nm 60 consecutive measurements) ≤0.00020A at 0A at 260 and 500 nm ≤0.00030A at 1A at 260 and 500 nm ≤0.00040A at 2A at 260 and 500 nm |
Optical Design | Double Beam |
Photometric Display | –3A to +5A |
Photometric Range | –2A to +3.5A |
Photometric Repeatability | ±0.001A at 1A measured at 1.0A at 546 nm |
Spectral Bandwidth | 2 nm |
Stray Light | < 1.0%T 198 nm (KCl) , <0.05%T at 220 nm (NaI), <0.03%T at 340 nm (NaNO2) |
Wavelength Data Interval | 0.1 nm, 0.2 nm, 0.5 nm, 1 nm, 2 nm, 5 nm |
Wavelength Repeatability | ±0.2 nm |
Wavelength Scan Speed | Slow, medium and fast – up to 1600 nm/min |
Weight (Metric) | 7.5 kg |
840-309400
Empower your analysis and bring versatility and productivity to your lab with the Thermo Scientific™ Evolution 201 and 220 UV-Vis spectrophotometers. With next-generation Thermo Scientific™ INSIGHT™ software for both tablet-based and computer control, your instrument is always up to date and ready for the next sample challenge. Take your routine measurements to the next level with our Customized User Environment (CUE) software, which allows you to completely customize both the logical measurement steps and the output environmen
Accuracy (Photometric) | 0.5: ±0.004; 1: ±0.006; 2: ±0.010; Measured at 440nm using neutral density filters traceable to NIST |
Certifications/Compliance | ISO 9001:2008 |
Connections | USB or RS-232 |
Detector Type | Dual Silicon Photodiodes |
Display | None |
Operating System | INSIGHT 2 Software is compatible with Windows™ 7 and Windows 8.1 Professional Editions |
Photometric Accuracy Instrument | 1A: ±0.006A 2A: ±0.010A Measured at 440nm using calibrated neutral |
Type | Evolution 201 Spectrophotometer plus Tablet Control Module – International |
Wavelength Accuracy | ±0.5nm (541.9, 546.1nm mercury lines); ±0.8nm (full range 190 to 1100nm) |
Wavelength Range | 190 to 1100nm |
Baseline Flatness | ±0.0010A, 200-800nm, 1.0nm SBW, smoothing |
Beam Geometry | Double-beam |
Data Interval | 10, 5, 2, 1.0, 0.5, 0.2, 0.1nm |
Depth (English) | 24.3 in. |
Depth (Metric) | 62.2mm |
Description | Cutting-edge instrumentation, intuitive and powerful software, and a wide range of accessories consistently deliver high quality results and improved productivity. |
Dimensions (L x W x H) | 62.2 x 48.6 x 27.9 cm (24 x 19 x 11 in) |
Drift | <0.0005A/hr, 500nm, 1.0nm SBW, 1 hr warm-up |
Electrical Requirements | 100-240V 50-60Hz, selected automatically, 150W maximum |
Item Description | Evolution 201 Tablet Control Module Intl |
Keypad | Sealed membrane |
Lamp | Xenon Flash Lamp, 3 year warranty (7 years typical lifetime) |
Noise | 0A: <0.00015A; 1A:<0.00025A; 2A: <0.00080A; 260nm, 1.0nm SBW, RMS |
Optical Design | Double Beam with sample and reference cuvette positions; Czerny-Turner Monochromator |
Pathlength (Metric) | Up to 100mm cuvettes |
Pharmacopoeia Compliance Testing | Resolution (Toluene in Hexane): ≥1.8A Photometric Accuracy (60mg/L K2Cr2O7): ±0.010A Stray Light: ≤1%T at 198nm: KCI; ≤0.05%AT at 220nm: Nal, Kl Wavelength Accuracy: ±.5nm 541.9, 546.1nm Hg emission lines, ±0.8nm full range Wavelength Repeatability: ≤0.05nm, repetitive scanning of 546.1nm Hg emission line |
Photometric Display | -0.3 to 4.0A |
Photometric Range | >3.5A |
Photometric Repeatability | ±0.0002A |
Scan Ordinate Modes | Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, log (1/R). log (Abs) Abs*, Intensity |
Scan Speed | <1-6000nm/min, variable |
Spectral Bandwidth | 1.0nm |
Wattage | 150W max. |
Wavelength Repeatability | ≤0.05nm (546.1nm mercury line, SD of 10 measurements) |
912A0890
Thermo Scientific™ SPECTRONIC™ 200 is the standard for rugged, simple-to-use visible spectrophotometers for teaching applications. Designed expressly for the teaching laboratory, the SPECTRONIC 200 spectrophotometer includes a removable, washable sample compartment that simplifies spill cleanup and two cuvette racks to help students organize their samples during measurement. With thousands of instruments installed in teaching laboratories since its introduction, the SPECTRONIC 200 is the true successor to the legendary Thermo Scientific SPECTRONIC 20 spectrophotometer
Accuracy (Photometric) | ±0.01A at 0.3A; ±0.05A at 1.0A (SPECTRONIC standard filters measured at 590nm) |
Connections | USB-B for a connection to a remote computer USB-A for connection to a printer or USB memory device |
Detector Type | 2048 element CCD |
Display | Color graphical TFT LCD, 3.5 in. diagonal |
Interface | USB-B; USB-A |
Photometric Accuracy Instrument | ±0.01A at 0.3A; ±0.05A at 1.0A (SPECTRONIC standard filters measured at 590 nm) |
Printer | External printer support: Epson TM-T88V |
Range (Photometric) | -0.3 to 2.5Å |
Wavelength Accuracy | ±2 nm |
Wavelength Range | 340 – 1,000 nm |
Beam Geometry | Single beam |
Compartments | Removable, washable sample compartment |
Container Type | Single cell holder for square cuvettes and for test tubes |
Data Interval | 0.5 nm actual; 1 nm display under local control |
Data Interval for Scanning | 1 nm on-board, 0.5 nm under computer control |
Depth (English) | 11.8 in. |
Depth (Metric) | 30 cm |
Description | SPECTRONIC 200 Educator Model, Visible Spectrophotometer; Educator model does not include programmable Analyzer Mode |
Display Range | -0.3A – 2.5A; 0 – 125%T |
Electrical Requirements | Selected automatically, 100/240V 50/60Hz |
Height (Metric) | 16 cm |
Includes | Two Cuvet Racks; Ten 1cm plastic cuvets |
Keypad | Sealed tactile rubber |
Lamp | Tungsten-halogen (typical lifetime 1000 hrs) |
Languages | English, Spanish, Thai |
Measurement Range | -0.3 to 2.0A |
Optical Design | Single Beam |
Photometric Readout | ABS, %T, Concentration (standard or custom units) |
Photometric Repeatability | ±0.03A at 0.3A |
Spectral Bandwidth | <4 nm |
Stray Light | <0.2%T (with SPECTRONIC standard SRM 400 filter) |
Wavelength Repeatability | ±1 nm |
Weight (English) | 9.7 lb. |
Weight (Metric) | 5.2 kg |
Width (English) | 15.3 in |
840-282500
For routine, complex research and advanced applications, including current compliance, the Thermo Scientific Evolution One/One Plus UV-Vis Spectrophotometer series brings together reliable, versatile hardware, a broad range of accessories, with easy-to-use, easy-to-learn Thermo Scientific Insight Pro Software.
Description | Evolution One Plus Security and Validator Bundle includes: -Evolution One Plus UV-Vis Spectrometer -INSIGHT Pro with Security Software -Validator for Insight Pro A4 Ltr Paper Version -Qualification Filter Kit for UV-Vis |
Item Description | Evolution One Plus Security and Validator Bundle – INTL |
Spectral Bandwidth | Variable: 1.0 nm; 2.0 nm; AFBG Microcell optimized; AFBG Fiber optic optimized; AFBG Materials optimized |
Unit Size | Each |
840-370800
Designed for laboratories requiring higher performance, the Thermo Scientific™ Evolution™ 350 UV-Vis Spectrophotometer’s double beam optical design delivers precision and outstanding reliability for advanced applications. From sample to final report, intuitive software quickly guides you through each step of your analysis. Comprehensive tools for data collection, processing and reporting deliver the results you need for quantitative analysis, scanning and kinetics applications. Expansive accessory choices offer flexibility to analyze almost any sample type
Certifications/Compliance | Certificate of Analysis (COA), Certificate of Conformance (COC) |
Detector Type | Dual Matched Silicon Photodiodes |
Photometric Accuracy Instrument | 1A: ±0.004 A 2A: ±0.004 A 3A: ±0.006 A Measured at 546 nm using ne |
Wavelength Accuracy | ±0.20 nm (546.11 nm Hg emission line), ±0.30 nm 190–900 nm |
Wavelength Range | 190–1100 nm |
Applications | Academic, Chemicals, Food & Beverage, Chemicals Environmental, Industrial QA/QC, Material Science, Pharmaceuticals |
Baseline Flatness | ±0.0015 A (200–800 nm) 2.0 nm SBW, smoothed |
Description | Evolution 350 UV-Vis Spectrophotometer with Mercury lamp |
Dimensions (L x W x H) | 53 x 61 x 38 cm / 20.8 x 24 x 14.9 in. |
Drift | <0.0005 Abs/hour, 500 nm, 2.0 nm SBW, 2 hr warm-up |
Electrical Requirements | 100–240 V, 50–60 Hz |
Lamp | Xenon Flash Lamp Typical Lifetime: >5 years. Longer if not using live signal Warranty Period: 3 year source replacement warranty Low pressure mercury vapor lamp Used when performing performance verification (PV) tests for wavelength accuracy and spectral bandwidth. |
Noise | Photometric 0A: <0.00018 A 1A: <0.00022 A 2A: <0.00050 A 500 nm, 2.0 nm SBW, RMS |
Optical Design | Modified Ebert; Double beam with sample and reference cuvette/accessory positions |
Pharmacopoeia Compliance Testing | Wavelength Accuracy: ±0.3 nm 190–900 nm Wavelength Repeatability: SD 10 meas. <0.1 nm Absorbance Accuracy: <±0.010A at 1A, <±0.010A at 2A Absorbance Repeatability: ±0.0025A @ 1A Stray Light: 198 nm with KCl >2A, 220 nm with NaI >3A, 300 nm with acetone >3A, 340 nm with NaNO2 >3A Resolution: Peak/trough ratio >1.8 @ 1 nm SBW setting |
Photometric Display | ±6 A |
Photometric Range | >4 A |
Photometric Repeatability | 1A: ±0.0025 A |
Scan Ordinate Modes | Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, Log(1/R), Log(Abs), ABS × Factor, Intensity, 1st–4th Derivative |
Spectral Bandwidth | Selectable 0.5, 1.0, 1.5, 2.0, 4.0 nm |
Stray Light | 198 nm: 2.4 A KCl 220 nm: 3.5 A NaI 340 nm: 4.0 A NaNO2 |
Wavelength Data Interval | 10, 5, 2, 1, 0.5, 0.2, 0.1, 0.05 nm |
Wavelength Repeatability | Standard deviation of 10 measurements <0.05 nm |
Wavelength Scan Speed | Variable, up to 6000 nm/min |
Designed for laboratories requiring higher performance, the Thermo Scientific™ Evolution™ 350 UV-Vis Spectrophotometer’s double beam optical design delivers precision and outstanding reliability for advanced applications. From sample to final report, intuitive software quickly guides you through each step of your analysis. Comprehensive tools for data collection, processing and reporting deliver the results you need for quantitative analysis, scanning and kinetics applications. Expansive accessory choices offer flexibility to analyze almost any sample type
Certifications/Compliance | Certificate of Analysis (COA), Certificate of Conformance (COC) |
Detector Type | Dual Matched Silicon Photodiodes |
Photometric Accuracy Instrument | 1A: ±0.004 A 2A: ±0.004 A 3A: ±0.006 A Measured at 546 nm using ne |
Wavelength Accuracy | ±0.20 nm (546.11 nm Hg emission line), ±0.30 nm 190–900 nm |
Wavelength Range | 190–1100 nm |
Applications | Academic, Chemicals, Food & Beverage, Chemicals Environmental, Industrial QA/QC, Material Science, Pharmaceuticals |
Baseline Flatness | ±0.0015 A (200–800 nm) 2.0 nm SBW, smoothed |
Description | Evolution 350 UV-Vis Spectrophotometer with Mercury lamp |
Dimensions (L x W x H) | 53 x 61 x 38 cm / 20.8 x 24 x 14.9 in. |
Drift | <0.0005 Abs/hour, 500 nm, 2.0 nm SBW, 2 hr warm-up |
Electrical Requirements | 100–240 V, 50–60 Hz |
Lamp | Xenon Flash Lamp Typical Lifetime: >5 years. Longer if not using live signal Warranty Period: 3 year source replacement warranty Low pressure mercury vapor lamp Used when performing performance verification (PV) tests for wavelength accuracy and spectral bandwidth. |
Noise | Photometric 0A: <0.00018 A 1A: <0.00022 A 2A: <0.00050 A 500 nm, 2.0 nm SBW, RMS |
Optical Design | Modified Ebert; Double beam with sample and reference cuvette/accessory positions |
Pharmacopoeia Compliance Testing | Wavelength Accuracy: ±0.3 nm 190–900 nm Wavelength Repeatability: SD 10 meas. <0.1 nm Absorbance Accuracy: <±0.010A at 1A, <±0.010A at 2A Absorbance Repeatability: ±0.0025A @ 1A Stray Light: 198 nm with KCl >2A, 220 nm with NaI >3A, 300 nm with acetone >3A, 340 nm with NaNO2 >3A Resolution: Peak/trough ratio >1.8 @ 1 nm SBW setting |
Photometric Display | ±6 A |
Photometric Range | >4 A |
Photometric Repeatability | 1A: ±0.0025 A |
Scan Ordinate Modes | Absorbance, % Transmittance, % Reflectance, Kubelka-Munk, Log(1/R), Log(Abs), ABS × Factor, Intensity, 1st–4th Derivative |
Spectral Bandwidth | Selectable 0.5, 1.0, 1.5, 2.0, 4.0 nm |
Stray Light | 198 nm: 2.4 A KCl 220 nm: 3.5 A NaI 340 nm: 4.0 A NaNO2 |
Wavelength Data Interval | 10, 5, 2, 1, 0.5, 0.2, 0.1, 0.05 nm |
Wavelength Repeatability | Standard deviation of 10 measurements <0.05 nm |
Wavelength Scan Speed | Variable, up to 6000 nm/min |
Weight (English) | 48.5 lbs |
Weight (Metric) | 22 kg |
912A0959