UV300 ONLINE WATER ANALYSER

ONLINE PROCESS ANALYZERS

UV 500 / 500 Compact

UV 400 / 400 ATEX

UV 300 / 300 5D

EL 300

EL 200

UV-VIS200

CEM 500 / 500-L

CEM 400

EXM 500 / 500-L

EXM 400

  • PROBES

UV300 ONLINE WATER ANALYSER

The UV300 is a cost effective water analyser for applications focused on one or two parameters.

UV 300 ONLINE WATER ANALYSER
 

The UV300 is a cost effective water analyser for applications focused on one or two parameters.
Mainly based on UV spectroscopy, well known for its stability and low operating cost, the UV300 can measure parameters like organic matter, nitrate, colour, aromatics hydrocarbons (PAH).A complementary module allows the measurement of PO4, Cl2, NO2, Fe, Al by colorimetric method and turbidity by laser diode. External probes can be added for physicochemical parameters like pH, ORP, dissolved oxygen and conductivity.

Thanks to its automatic cleaning system and its extremely long life time lamp, the maintenance is roughly limited to the periodic refill of the inexpensive cleaning solution. A new web-based interface allows the control and the troubleshooting from internet on laptop, tablet or i-phone.

 
MAIN METHOD : UV-VISIBLE SPECTROSCOPY
  • The most common measurements (UV254, NO3, Colour, PAH) are based on the UV-VIS spectroscopy that brings fast and stable measurements with a simple hydraulic circuit for a high reliability.
  •  
  • All theses measurements are done within 5 seconds. The turbidity of the sample is automatically compensated by a dual-wavelength method as shown on the figure.
  •  
  • The UV source is a xenon flash lamp specified for 109 flashes that corresponds to more than 10 years of life time with one measurement every minute.
  •  
  • For PO4, Cl2, NO2, Al, Fe, SiO2, a colorimetric module has been specially developed to reach a very small volume flow cell that reduces the quantity of reagent to preserve the environment and to reduce the operating cost. A multi-wavelength LED source assumes a colour and turbidity compensation with an unlimited life time.
  •  
  • The patented flow cell allows very high level of suspended solid without clogging for all the optical measurements.
  •  
  • Physico-chemical measurements like pH, ORP, dissolved oxygen, conductivity can be added to the internal measurements by using external probes. The dissolved oxygen probe is based on fluorescence method for a lower maintenance and higher stability. Turbidity can also be measured by external probes.
  •  
  • Three external turbidity probes (high, medium and low range) are also available if the measurement need to be done in situ, for example before filtering.
ROBUST INDUSTRIAL PROBES

All the probes are specially designed for harsh environments with high level of suspended solid.

USER-FRIENDLY INTERFACE

The colour touch screen and intuitive interface available in 8 different languages (Chinese, English, French, German, Italian, Portuguese, Spanish, Turkish) makes very easy to test or configure the analyser. Many test functions allows to test and troubleshoot each element of the analysers (light signal, pumps, solenoid valves, etc…) to setup quickly a maintenance diagnostic.

MULTIPLEXING SYSTEM
When different streams need to be analysed, for example inlet and outlet of a plant, an optional multiplexing system delivers relay contacts to control external electric-valves or external pumps.
Up to 6 different streams can be selected
The Standard channels can be either duplicated (each one having its own 4-20mA output or MODBUS register), or measured sequentially to fit with the maximum of 16 Standard channels (a MODBUS register tells which stream is currently being measured).
SAMPLING SYSTEM

The UV300 can adapt to many different kind of sampling depending of the application : surface water, drinking water, process water or wastewater.

 

If the water is already pressurized, the sample can be admitted directly inside the analyser with a maximal pressure of 4 bars. Otherwise an optional built-in peristaltic pump, synchronised with the measurement to extend the tubing life time, allows to take the sample directly from a tank located up to 6 meters below the analyser. For demanding applications with long distances, another peristaltic pump in a separate enclosure is proposed as an option. For some applications on river water or wastewater where two sampling pumps are necessary, the UV300 delivers a relay contact to synchronise the primary pump. The delay and running time of each pump can be adjusted easily in the parameters menu of the analyser. More…
ONLINE WATER ANALYZER, UV300 – PARAMETER SPECIFICATION

 

PARAMETERSTANDARD RANGE
OTHER RANGES ON REQUEST
TYPICAL REPEATABILITY
FOR LOW VALUES (<10% FS)
ACCURACY
ON STANDARD SOLUTION
UV2540-200 Abs/m
0-600 Abs/m
0-2000 Abs/m
+/- 0.05 Abs/m
+/- 0.15 Abs/m
+/- 0.5 Abs/m
+/- 2%
COD by UV correlation0-100 mg/l COD
0-2000 mg/l COD
0-20,000 mg/l COD
+/-0.05 mg/l COD
+/- 1 mg/l COD
+/- 10 mg/l COD
+/- 2%
BOD by UV correlation0-100 mg/l BOD
0-1000 mg/l BOD
0-10,000 mg/l BOD
+/-0.05 mg/l BOD
+/- 0.5 mg/l BOD
+/- 5 mg/l BOD
+/- 2%
TOC by UV correlation0-100 mg/l TOC
0-100 mg/l TOC
0-10,000 mg/l TOC
+/-0.05 mg/l TOC
+/- 0.5 mg/l TOC
+/- 5 mg/l TOC
+/- 2%
Nitrate0-100 mg/l NO3+/- 0.1 mg/l NO3+/- 2%
Colour0-100 Pt/Co
0-1000 Pt/Co
+/- 1 Pt/Co
+/- 2 Pt/Co
+/- 2%
PAH (aromatics)0-10 mg/l C6H6+/- 0.01 mg/l C6H6+/- 2%
Chlorophyll A0-100 µg/l ChlA+/- 1 µg/l ChlA+/- 2%
Oil in Water0-100 ppm OIW
0-1000 ppm OIW
+/- 0.1 ppm OIW
+/- 1 ppm OIW
+/- 2%
Phosphate (PO4)0-2 mg/l P-PO4
0-20 mg/l P-PO4
+/- 0.01 mg/l P-PO4
+/- 0.1 mg/l P-PO4
+/- 2%
Chlorine0-5 mg/l Cl2+/- 0.05 mg/l Cl2+/- 2%
Nitrite0-5 mg/l NO2+/- 0.1 mg/l NO2+/- 2%
Nitrite0-5 mg/l NO2+/- 0.1 mg/l NO2+/- 2%
Aluminium0 – 500 ppb Al+/- 10 ppb Al+/- 2%
Iron0-2 mg/l Fe+/- 0.02 mg/l Fe+/- 2%
Silica0-20 mg/l SiO2+/- 0.1 mg/l SiO2+/- 2%
Cr VI0-2 mg/l Cr VI+/- 0.04 mg/l Cr VI+/- 2%
Turbidity
(TSS by correlation)
0-10 NTU
0-100 NTU
0-1000 NTU
+/- 0.01 NTU
+/- 0.1 NTU
+/- 1 NTU
+/- 2%
pH0-14 pH+/- 0.01 pH+/- 2%
ORP+/- 2000 mV+/- 1 mV+/- 2%
Dissolved Oxygen (DO)0-25 mg/l O2+/- 0.1 mg/l O2+/- 2%
Conductivity0-2000 µS+/- 1 µS+/- 2%
External turbidity
(TSS by correlation)
0-4 NTU
0-40 NTU
 +/- 2%
+/- 2%
External TSS0-1500 mg/l
0-30000 mg/l
+/- 1% of reading or +/- 2 mg/l TSS
+/- 1% of reading or +/- 2 mg/l TSS
+/- 2%
+/- 2%
Temperature0-80 °C+/- 0.1°C+/- 2%

 

ONLINE WATER ANALYZER, UV300 – GENERAL SPECIFICATION

 

Sample flowRecommended: 0 – 5 l/min
Sample pressure0 – 4 Bar (0 – 1 Bar with sampling peristaltic pump)
Sample temperature0 – 80 °C
Wet parts materialQuartz, Polypropylene, Polyethylene, FPM (viton), PMMA
Measuring time5 sec (except PO4, NO2, Fe, Cr(VI) : 3mn /, Cl2, Al : 2mn / SiO2 : 6 min)
Measurement interval1 min to 720 min (If measuring time compatible)
Physicochemical parameters may be continuous
Memory5000 lines of measurements (up to 16 channels) with date and time
ConsumptionCleaning solution (5% sulfuric acid): 220 ml/day
Reagent per measurement : Al : 0.5ml /
Cl2, PO4, Fe, NO2, Cr(VI) : 0.6 ml / Sio2 : 1.2 ml
Maintenance intervalRecommended: 6 months to 1 year (except for refilling)
Power supply90 – 264 VAC 50/60 Hz 40 VA – 12v DC 3A maxi
ScreenColour TFT LCD 320×240 pixels with LED backlight
CommunicationRS232, Modbus or HTTP/Web interface, compatible with Windows7, with Internet Explorer version 9, Nexus 7 tablet under Android with Opera version 12.10, Apple I-phone 4S with Safari

RS485 for external probes (DO, TSS)
USB
WI-FI (IEEE802.11B) optional
Ethernet (IEEE802.3) optional
CertificationsCE, EN 61010-1, EN 61326
EnclosureStainless steel with epoxy coating, IP65, wall mounting brackets
Dimensions420 x 360 x 200 mm
Weight15 to 20 kg depending on the configuration

ONLINE WATER ANALYZER, UV300 – ACCESSORIES

 

SAMPLING PUMP PRODUCT CODE: P-EXT
External Peristaltic sampling pump for unpressurized water
Flow of about 940 ml/min
Heavy duty brushless motor
Discontinuous operating to increase tube lifetime
SAMPLING PUMP PRODUCT CODE: P
Sampling peristaltic pump for unpressurized water
Built-in on the left side of the enclosure
Flow of about 0.6 litre/min
Discontinuous operating to increase tube lifetime
INPUT MODULES PRODUCT CODE: MI4-20
4-20 mA input module
Isolated 4-20 mA input
Impedance: 100 Ohm
INPUT MODULES PRODUCT CODE: MIL
Double logical inputs module
Input no 1 : external pulse command for measurement
Input no 2 : measurements inhibition
Isolated 0 – 48 V DC inputs
Impedance: >10 Kohm
OUTPUT MODULES PRODUCT CODE: MO4-20
4-20 mA output module
Isolated 4-20 mA output
Active output, Max load 500 Ohm
OUTPUT MODULES PRODUCT CODE: MRELAY
Relay module
Contact rating: 2A/220V
Maximum 6 relays modules allowed
COMMUNICATIONS PRODUCT CODE: WIFI400
Wifi Interface
Connection to wireless WIFI network
Secured data transfer (WEP keys)
COMMUNICATIONS PRODUCT CODE: ETHER400
Ethernet interface
Ethernet 10 base-T (IEEE 802.3)
COMMUNICATIONS PRODUCT CODE: MTI133
Phone modem
Industrial modem 33,6 Kb/s V34+
DIN rail Mounting
Power supply 24V from the analyser
COMMUNICATIONS PRODUCT CODE: GSM
GSM modem
Dual band (EGSM 900/1800 MHz)
Integral SIM card reader
R & TTE approved
DOWNLOAD UV300 ONLINE WATER ANALYZER DETAIL

Brochures/ Data Sheet

Dimensional Drawing

UV300-5D ONLINE ANALYSER FOR DRINKING WATER

The UV300-5D is a pre-defined configuration of the UV300 analyser dedicated to drinking water monitoring.

The UV300-5D is a pre-defined configuration of the UV300 analyser dedicated to drinking water monitoring.
It offers the possibility to monitor simultaneously FIVE parameters :
(1) Total residual chlorine    (2) Turbidity    (3) pH    (4) Conductivity    (5) Temperature
All this is done by a single unit that allows high performance measurements at a cost effective price. An automatic cleaning system maintains clean the flow cell and also make an auto-zero that guaranties the absence of long term drift.

COLORIMETRIC DPD METHOD : A Reliable Method for Total Residual Chlorine
  • The US-EPA 330.5 (or standard methods 4500-Cl-G) DPD method is internationally recognized for its good accuracy and stability, while specific electrodes for chlorine may drift or show a sensitivity to the sample flow.
  •  
  • Other oxidising agents are also taken in account by the DPD method, that makes it the best choice method.
  •  
  • The colorimetric module has been specially developed to reach a very small volume flow cell (7ml) that reduces the quantity of reagent to preserve the environment and reduce the operating cost.
  •  
  • A multi-wavelength LED source assumes a colour and turbidity compensation with an unlimited life time. Large bore tubing avoid clogging as accumulated sediments might be a problem even on drinking water for long term operation.
PATENTED FLOW CELL
  • The patented flow cell allows very high level of suspended solid without clogging for all the optical measurements making it suitable for industrial and municipal waste water application. The turbidity is automatically compensated by a dual-wavelength method.
  • Suitable for sample with high chloride content
  • Wetted parts of flow cell make it suitable for most corrosive sample
TURBIDITY BY LASER DIODE (NEPHELOMETRIC)

The turbidity module is based on a high stability laser diode to reach low level of detection as required for drinking water. The automatic cleaning system allows to perform an auto-zero once per day to guaranty the absence of drift on long term. It avoid also the accumulation of sediments that may perturb the measurement. The laser diode could be either a red visible model to ease the maintenance and troubleshooting, or a infra-red model to follow the ISO 7027 nephelometric method at 860 nm. More…

ONLINE ANALYSER FOR DRINKING WATER, UV300-5D – PARAMETER SPECIFICATION

 

PARAMETERSTANDARD RANGE
OTHER RANGES ON REQUEST
TYPICAL REPEATABILITY
FOR LOW VALUES (<10% FS)
Total residual chlorine0 – 5 mg/l+/- 0.01 mg/l
Turbidity0 – 10 NTU+/- 0.02 NTU
pH0 – 14+/- 0.01 pH
Conductivity0 – 2000 μS+/- 1 μS
Dissolved oxygen (option)0 – 25 mg/l O2+/- 0.02 mg/l O2
Temperature0 – 80 °C+/- 0.1 °C

 

ONLINE ANALYSER FOR DRINKING WATER, UV300-5D – GENERAL SPECIFICATION

 

Sample flow0.05 – 1 l/min
Sample pressure0 – 4 Bar
Sample temperature0 – 50°C
Wet parts materialQuartz, Polypropylene, Polyethylene, FPM (viton), PMMA
Measuring time5 sec for turbidity, pH, conductivity, 2 min for chlorine
Measurement interval2 min to 720 min for chlorine, other parameters are continuous
Memory5000 lines of measurements (for all channels) with date and time
ConsumptionCleaning solution (5% sulfuric acid): 220 ml/day
Reagent for Cl2 : 0.3 ml per measurement
Maintenance intervalRecommended: 6 months to 1 year (except for refilling)
Power supply90- 264 VAC 50/60 Hz 40 VA – 12V DC 3A maxi
ScreenColour TFT LCD 320×240 pixels with LED backlight
CommunicationRS232, MODBUS or HTTP/Web interface (Windows 7 with IE9, Android with Opera, Apple i-phone with Safari)
RS485 for additional probes (DO, pH)
USB
WI-FI (IEEE802.11B) optional
Ethernet (IEEE802.3) optional
CertificationsCE, EN 61010-1, EN 61326
ISO7027 for turbidity and US-EPA 330.5 for chlorine
EnclosureStainless steel with epoxy coating, IP65, wall mounting brackets
Dimensions420 x 360 x 200 mm
Weight14 kg approx.

ONLINE ANALYSER FOR DRINKING WATER, UV300-5D – ACCESSORIES

 

OUTPUT MODULES PRODUCT CODE: MO4-20
4-20 mA output module
Isolated 4-20 mA output
Active output, Max load 500 Ohm
OUTPUT MODULES PRODUCT CODE:MRELAY
Relay module
Contact rating: 2A/220V
Maximum 6 relays modules allowed
COMMUNICATIONS PRODUCT CODE:WIFI400
Wifi Interface
Connection to wireless WIFI network
300m nominal range (open space)
Secured data transfer (WEP keys)
COMMUNICATIONS PRODUCT CODE:ETHER400
Ethernet interface
Ethernet 10 base-T (IEEE 802.3)
COMMUNICATIONS PRODUCT CODE:MTI133
Phone modem
Industrial modem 33,6 Kb/s V34+
DIN rail Mounting
Power supply 24V from the analyser
COMMUNICATIONS PRODUCT CODE:GSM
GSM modem
Dual band (EGSM 900/1800 MHz)
Integral SIM card reader
R & TTE approved
DOWNLOAD UV300-5D ONLINE ANALYSER FOR DRINKING WATER DETAIL

Brochures/ Data Sheet

Dimensional Drawing

Follow by Email
LinkedIn
LinkedIn
Share