Generate an accurate turbidity reading quickly with the Thermo Scientific™ Orion™ AQUAfast AQ3010 Turbidity Meter. Perfect for the plant, field or lab, this simple yet powerful turbidity meter offers an impressive array of features. Use the Infrared (IR) LED light source to comply with ISO 7027 requirements and reliably measure turbidity with auto-ranging values from 0 to 1000 NTU. This IP67 waterproof meter offers a long battery life averaging about 3000 tests
Light Source | IR LED for ISO 7027 Turbidity measurement |
Product Type | Turbidity Meter |
Resolution | 0.01 NTU (0.01 to 19.99 NTU), 0.1 NTU (20.0 to 99.9 NTU), 1 NTU (100 to 1000 NTU) |
Automatic Range Selection | 0.01 to 19.99 NTU with 0.01 NTU resolution, 20.0 to 99.9 NTU with 0.1 NTU resolution, 100-1000 NTU with 1 NTU resolution |
Battery Life | 3000 Test |
Description | Turbidity Meter |
Display Type | LCD |
Key Functions | Power, Cal, Scroll Up, Scroll Down, Read/Enter |
Precision | ±2% of reading ±1 LSD for 0-500 NTU, ±3% of reading ±1 LSD for 501-1000 NTU |
Response Time | <6 sec. |
Temperature (Metric) Operating | 0° to 50°C |
IP Rating | IP67 |
Warranty | 90 Days (Limited) |
ISO Accepted Methods | ISO 7027 |
Certifications/Compliance | CE, TUV 3-in-1 for CSA-US, FCC part 15 |
Item Description | Turbidity meter kit |
AQ3010
Utilize advanced features with the Thermo Scientific™ Orion™ AQ4500 Turbidity Meter, including dual light sources and drinking water/wastewater methods approved for U.S. EPA regulatory reporting. Keep pace with changing regulatory protocols and use White Light LED to comply with EPA 180.1 requirements or Infrared (IR) LED to comply with ISO 7027 requirements. Select from measure modes including EPA 180.1, ISO Nephelometric, ISO Absorbance, % transmittance, EBC and ASBC. This IP67 waterproof meter records 100 data points and offers an average battery life of 2500 hours intermittent use
Light Source | LED, Multiple |
Product Type | Turbidity Meter |
Automatic Range Selection | Yes |
Battery Life | 2500 hr. |
Description | RS232 cable for method uploads and data downloads in AQ4000/AQ4500 |
Display Type | LED |
EPA Approved Methods | 180.1 |
ISO Accepted Methods | ISO 7027 |
Certifications/Compliance | US EPA approval for Drinking Water Reporting per 40 CFR Part 141, vol. 74, no. 147, Monday, August 3, 2009. Rules and regulations pg 38351-38356.EPA 180.1 and ISO 7 |
AQ4CBL
Lightweight and waterproof for turbidity measurements
Accuracy | < 0.1 NTU for 0.02 NTU standard; ±2 % of reading ±1 digit for 0 to 500 NTU; ±3 % of reading ±1 digit for 501 to 2000 NTU |
Calibration Type | Up to 4 points |
Dimensions (L x W x H) | Meter: 15.5 x 6.8 x 4.6 cm; Boxed: 35.5 x 16.5 x 10.5 cm |
Range | 0 to 2000 NTU |
Light Source | Infrared-emitting diode (850 nm wavelength) |
Product Type | Turbidity Meter |
Resolution | 0.01 NTU (0 to 19.99 NTU); 0.1 NTU (20.0 to 99.9 NTU); 1 NTU (100 to 2000 NTU) |
Automatic Range Selection | 0.01 to 19.99 NTU; 20.0 to 99.9 NTU; 100 to 2000 NTU |
Battery Life | 1200 Tests |
Battery Type | 4 x 1.5 V ‘AAA’ alkaline batteries (> 1200 readings) |
Description | Waterproof TN-100 handheld turbidimeter, set of 7 sample vials, lint-free cloth, silicone oil, batteries, and hard carrying case |
Display Type | LCD |
Optional Calibration Standards | 0.02 NTU, 20.0 NTU, 100 NTU, 800 NTU |
Response Time | < 6 secs for full step change |
Sample Size | 10mL |
Temperature (Metric) Operating | 0 to 50 °C |
IP Rating | IP 67 |
Weight (Metric) | Meter: 200g; Boxed: 1,16 0g |
ECTN100NOSTDS
Generate an accurate turbidity reading quickly with the Thermo Scientific™ Orion™ AQUAfast AQ3010 Turbidity Meter and its accessories. Perfect for the plant, field or lab, this simple yet powerful turbidity meter offers an impressive array of features. Use the Infrared (IR) LED light source to comply with ISO 7027 requirements and reliably measure turbidity with auto-ranging values from 0 to 1000 NTU. This IP67 waterproof meter offers a long battery life averaging about 3000 tests
For Use With (Equipment) | AQUAfast AQ3010 Turbidity Meter |
Type | Accessory |
Description | 25mm Vials, 3 Pack |
Unit Size | Each |
AC3V25
Case of 30 | 0.8 to 11mg/L ClO2 | Chlorine Dioxide | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
AC4099
Ensure your Thermo Scientific™ Orion™ AQUAfast™ AQ4500 Turbidity Meter has the accessories it needs with our selection of Orion™ AQUAfast™ AQ4500 Turbidity Meter Accessories that include turbidity vials, primary turbidity standards, Formazin turbidity standards, and more. Our Orion AQUAfast AQ4500 turbidity meter has advanced features, including dual light sources and drinking water / wastewater methods approved for U.S. EPA regulatory reporting. Keep pace with changing regulatory protocols; use the White Light LED to comply with EPA 180.1 requirements or Infrared (IR) LED to comply with ISO 7027 requirements. Select from measure modes including EPA 180.1, ISO Nephelometric, ISO Absorbance, % transmittance, EBC and ASBC. This IP67 waterproof meter records 100 data points and offers an average battery life of 2500 hours intermittent use
For Use With (Equipment) | AQ4500 Turbidimeter |
Type | Turbidity Meter Accessory |
Description | Primary Standards for AQ4500, SDVB for 0, 1.0, 10, 100, 1000NTU |
EPA Approved Methods | US EPA approval for Drinking Water Reporting per 40 CFR Part 141, vol. 74, no. 147, Monday, August 3, 2009. Rules and regulations pg 38351-38356.EPA 180.1 and ISO 7031 |
Includes | Set of 5 USEPA approved primary calibration standards |
Unit Size | Each |
AC45ST
Optimize your Eutech™ TN-100 Turbidimeter with these accessories and replacement parts.
For Use With (Equipment) | TN-100 Turbidimeter |
Type | Calibration Kit Set |
Description | Calibration kit set – standard solutions (0.02, 20.0, 100, 800 NTU) 60 mL each and (4) vials |
Unit Size | Each |
TN100CALKIT
Choose the reagent tablets you need for Orion™ AQUAfast colorimeters and Thermo Scientific™ Orion™ AquaMate Vis and UV-Vis spectrophotometers with Thermo Scientific™ Orion™ AQUAfast II Chemistries Test Kits. These convenient, rapidly dissolving tablets can be precisely added to samples without leaving residual reagent in the packaging and are very stable for long shelf life accessibility. Tablet reagents measure alkalinity, aluminum, ammonia, boron, chloride, chlorine, chlorine dioxide, copper, DEHA, hardness, hydrazine, hydrogen peroxide, iron, manganese, nitrate, nitrite, ozone, pH, phosphate, potassium, silica, sulfate, sulfide and zinc.
For Use With (Equipment) | Orion AquaMate Vis and UV-Vis Spectrophotometers, Orion AQUAfast AQ3700 Colorimeter |
Test Method | Eriochrome Cyanine R |
Test Reagent Formats | Powder |
Type | Aluminum |
Description | AQUAfast Aluminum Powder Pack, 100 tests |
EPA Approved Methods | WW Equivalent |
Range | 0.01-0.25 mg/L |
Unit Size | Each |
AC4P27
Thermo Scientific™ Remel McFarland Equivalence Turbidity Standard is packaged in plastic case with a visual comparison card.
Description | Turbidity Standard Set |
Includes | 1 each of 0.5, 1.0, 2.0, 3.0, 4.0 |
Tubing Size | 15 x 103mm |
Unit Size | Each |
R20421