Number of Cups: 12 (9 for reagents, 3 for paraffin)
Capacity of Each Cup: 700 ml
Length of Processing Time in the Cup:
Any length between 0 and 99 hours for the first cup
Any length between 0 and 24 hours for the other cups
Temperature Range: RT – 80℃
Dripping Time: Approximately 30 s
Frequency of Agitation: 2 times/minute
Tissue Protection Cup: at the 7th station
Working Voltage: AC220V±10% 50Hz (standard model) AC110V±10% 60Hz
Power Requirements: 500 W
Heating Control: heating automatically begins when the tissue enters the 2nd cup, thus avoiding unnecessary energy waste
Dimensions: 795×435×415 mm (W×D×H)
Weight: 50kg
Fully intelligent design, enabling timely automatic determination and recovery from an abnormal event
High-quality blue-colored LCD screen operated with two optional programs offers a clear and reliable display
Manual adjustment can be conducted anytime during the programmed automatic operation; afterwards, the system automatically enters the programmed operation
Green inner-cycling air purification system to efficiently adsorb, and remove, poisonous gas
Imported high-quality parts, smooth operation, low noise, ergonomic design
Approximately 60 tissue samples can be processed at the same time
Imported high-quality parts, smooth operation, low noise, ergonomic design
Integrated high-quality LCD screen with intuitive bilingual (Chinese/English) software offers a clear display and simple operation; window-scrolling/flipping human-machine conversation interface provides clear instructions for each step (online help)
Well-sealed plexiglass cover with gas-effluxion mechanism, environmentally friendly and safe
Fully intelligent design, enabling timely determination and automatic recovery from an abnormal event
This system can be automatically started at any time as programmed
Processing duration is automatically calculated and displayed on the screen, allowing user to make a more efficient work plan
20 editable programs can be stored in the system
Manual adjustment can be conducted anytime during the programmed automatic operation; afterwards, the system automatically enters the programmed operation.
Frequency of agitation can be adjusted within a range of 0-6 times/minute (0 indicates no agitating), allowing, thorough, sufficient, and uniform reagent infiltration
Automated fan and light control:
The light will ‘on’ for two minutes when the device is on and in operation.
Fan is ‘on’ all the time when the specimens are not submerged in cup or during programming, and runs for 10 seconds every minute when the specimens are submerged in cup and in processing
Green inner-cycling air purification system to efficiently adsorb and remove poisonous gas
Internal dry heating mechanism with high-precision temperature control
Low-energy-consuming control circuit with power protection function: when a power outage occurs, the screen displays as normal with a scrolling bar demonstrating the ‘on’ status of the power protection system.
Imported high-quality parts, smooth operation, low noise and ergonomic design
Approximately 110 tissue samples can be processed at the same time
Number of Cups: 12 (the cups at the 10th, 11th, and 12th stations are used for paraffin melting)
Capacity of Each Cup: 1.8 L
Temperature range: RT – 80℃ ±1℃
Length of Processing Time in the Cup:
Any length for the first cup (Extended Time)
Any length between 0 and 24 hours for the other cups
Dripping Time: Adjustable within 10-60 s; shake/drip above cup
Frequency of Agitation: Adjustable within 0-6 times/minute
Working Voltage: AC220V 50Hz; AC110V 60Hz
Working Voltage: AC 220V±10% 50Hz (standard model); AC110V±10% 60Hz
Power: 500W
Dimensions: 1135×465×490 mm (W×D×H)
Net weight: 80kg
(With intelligent touch screen)
Number of Cups: 12 (The 1st to 9th stations for reagents and the 10th to 12th stations for paraffin melting)
Capacity of Each Cup: 2000 ml
Temperature Range: RT – 80℃
Temperature Control Precision: ±1℃
Length of Processing Time in the Cup:
Any length for the first cup (Extended Time)
Any length between 0 and 24 hours for the 2nd to 12th cup
Dripping Time: Adjustable between 10s and 60s; shake/drip function above cup
Frequency of Agitation: Adjustable within 0 – 6 times/minute
Tissue Protection Station: any station from the 1st to 7th station as preset
Working Voltage: AC220V±10% 50Hz (standard model)AC110V±10% 60Hz
Power: 500 W
Dimensions: 1170×465×535mm (W×D×H)
Net weight: 85kg
Number of Cups: 14(10 for reagents, and the cups at the 11th, 12th, 13th, and 14thstations are used for paraffin melting)
Two baskets;
Capacity of Each Cup: 2000ml
Temperature range: RT – 800C;
Temperature Control Precision: ±10C;
Length of Processing Time in the Cup:
Any length between 0 and 99 hours for the 1st and 2nd cup
Any length between 0 and 24 hours for the 3nd to 14th cup
Dripping Time: Adjustable within 10s – 60s; shake/drip above cup
Frequency of Agitation: 0 – 6 times/min adjustable;
Dehydration basket is divided into three layers to ease the categorization of tissue.
Working Voltage: AC 220V±10% 50Hz (standard model); AC110V±10% 60Hz
Power: 550W
Dimensions: 1370×440×525 mm (W×D×H)
Weight: 102kg
Description
KD-TS3B Automated Tissue Processor is mainly used in middle laboratories to process specimens to improve the quality sections. The max number of specimens processed is 80 each time. It is popular in the market because of its space saving and simple operation.
Features
APS-coated, streamlined-designed, easy-to-clean, sturdy housing with high resistance to corrosion
Imported high-quality parts, smooth operation, low noise, ergonomic design
20 editable programs can be stored in the system
Integrated high-quality LCD screen with intuitive bilingual (Chinese/English) software offers clear display and simple operation; window-scrolling/flipping human-machine conversation interfaceprovides clear instructions for each step (online help)
Fully intelligent design enables timely determination and automatic recovery from an abnormal event
Real-time visual simulation with icons displays working status dynamically, clearly and intuitively
Green inner-cycling air purification system to efficiently adsorb, remove poisonous gas; gas-effluxion mechanism, environmentally friendly and safe
This system can be automatically started at any timeas programmed
Processing duration is automatically calculated and displayed on the screen, allowing user to make a more efficientwork plan
Manual adjustment can be conducted anytime during the programmed automatic operation; afterwards, the system automatically enters the programmed operation
Automated fan control: Stays ‘on’all the time when the specimens are not submerged in cup and comes on 10 seconds every minute when the specimens are submerged in cup and in processing
Automated light control:
stays ‘on’all the time during programming;
stays ‘off’during the automatic operation and can be automatically turned ‘on’ anytime by touching the screen or any key and stays ‘on’ for 2
Internal dry heating mechanism with high-precision temperature control
Low-energy-consuming control circuit with power protection function.
When power outage occurs, the screen displays as normal with a scrolling bar demonstrating the ‘on’ status of the power protection system.
Battery backup with more than 30 hours of running power
Approximately 100 tissue specimens can be dehydrated at the same time
Number of Cups: 12 (9 for reagents, and the cups at the 10th, 11th, and 12th stations are used for paraffin melting)
Capacity of Each Cup: 1500ml
Length of Processing Time in the Cup:
Any length for the first cup (Extended Time)
Any length between 0 and 24 hours for the other cups
Temperature Range: RT – 80℃
Dripping Time: Adjustable within 10-60 s; shake/drip above cup
Frequency of Agitation: Adjustable within 0-6 times/minute
Tissue Protection Station: any station from the 1st to 7th station as preset
Working Voltage: AC220V±10% 50Hz (standard model); AC110V±10% 60Hz
Power: 500 W
Dimensions: 1055×480×495 mm (W×D×H)
Net weight: 75 kg
■ Operator Interface of 15 inch color LCD touch screen
■ Enclosed Tissue treatment system with no pollution of gas leakage, to meet requirement of environmental protection.
■ Mode of Sample processing: Sample not move,Reagent move.
■ it can avoid the risk of power failure of machine, or other mechanical failure.
■ Timing Mode: Finishing time of tissue processing any day in the week can be set
■ Fuction of Protection System of Power Failure.Once main power restored, the previous protocols is automatically resumed and continue to work in order.
■ 10 Set of Programmes stored in the system and can be set for purpose.
■ Special design of Reagent Station makes the liquid totally back-flow to avoid any mixture and to extend using time of reagent.
■ Patented design of cassette holder makes reagent and samples thoroughly contact with each other,it improves effection of tissue processing and reduce working time.
■ Dual Purpose of processing: one key switch normal processing motion and Rapid processing motion
■ Rapid Processing motion stirred in day time finished in 3 hours,Normal Processing Motion stirred in the evening.
■ Device for Air pressure transfer: Formal air pressure transfer of several solenoid valves replaced by One single mechanical structure replace formal in order to avoid high fault error.
■ Fuction for changing wax automatically:
■ Wax in No.1 Container wash into waste container,then,wax in NO.2 container goes into No.1 Container,then,No.3 goes into No.2,and so on
■ Fuction of over temperature protection occured by accidental heating
■ Fuction for magnetic stirring which shorten time of tissue processing and make good processing effection.
■ Alarm and Screen display when finishing work.
■ Capacity of tissue processing: 300pcs cassette at most.
■ Bottle amount : 12. 1 – 9 for dehydration reagent, 14 – 16 for cleaning agent
■ Nos of Reagent Station: 12
■ Tissue Processing Station: NO.1 to No.9 Station
■ Washing Station: No.14 to No.16 Station
■ Nos of Wax Tank: 3(No.10,12 and 13)
■ Nos of Working Station: 1
■ Capacity of Processing Station: 9Liters
■ Capacity of Reagent Station :6L
■ Temp.of Processing Station:
■ Medium is the solvent: ≤45℃
■ Medium is the Wax: 58℃-70℃
■ Operation pressure:<0.1Mpa
■ Wax temperature :58℃-70℃
■ Wax melt time not more than 3 hours
■ Power input:<1500VA+10%
■ Time for immerse: 0 – 99 hours 59 minutes
■ Working Voltage:220VAC±10%,50/60HZ
■ Time for Inflow Liquid: no more than 5Min
■ Time for Exclude Liquid: no more than 5Min
■ Stirring time: set randomly
■ Interval time for Stirring: set randomly
■ Operation mode: manual and automatic
■ Paraffin temperature – adjustable in the range of55°C-80°C
■ Temperature of reagents up to0°C-45°C