Online degassing of filter membrane can be realized with high efficiency vacuum pump negative pressure value up to 98kPa·
Temperature control range: room temperature -50℃ · Micro brushless dc micro water pump with integrated control, no pulsation of water flow and real-time feedback of flow · Three-level user authority management, 7 user accounts, providing convenience for different user operation experiments · LCD touch control system with large screen, easy to operate and clear display ·
Biometricidentification, easy to login, avoiding the cumbersome login mode of traditional account + password · built-in micro-printer to realize effective backup of experimental data ·Remote operation
·Online degassing of filter membrane can be realized with high efficiency · vacuum pump negative pressure value up to 98kPa
·Temperature control range: room temperature -50℃
Vacuum degree | 98Kpa (highest) |
Velocity regulating | 30%-100% |
Heating power | 1500W |
Volume of quantitative | 15L |
Quantitative accuracy | 10L±1% |
Number of users | 7 |
User level | 3 |
User program | 99 |
Recording keep | 128*366 days |
Relying on strong scientific research and technical strength, the company has accumulated rich experience in ultrasonic cell crushing, extraction, dispersion, descaling, high-pressure homogenization and ultra-low temperature, freeze-drying, genetic cell reorganization, laboratory automation and other technical fields, and has successively researched and developed Including biological sample pretreatment instruments, molecular biology instruments, laboratory cleaning equipment, freeze-drying equipment, industrial scale prevention and descaling equipment, freshwater resources algae removal and prevention and control equipment and other products. The company always adheres to the industry’s cutting-edge technology research and application development, and is committed to providing customers with advanced product equipment and industry solutions.
2.3.1 Treatment medium: it can directly deal with solvents, pure water, distilled water, etc. commonly used in dissolution experiments;
2.3.2 Accuracy of liquid output: Automatically complete quantitative liquid feeding, preheating, degassing and quantitative liquid discharge, and the volume control accuracy of liquid output volume can reach ± 1% , which can be directly added to the dissolution vessel, avoiding quantitative re-introduction in the middle. bubble.
2.3.3 On -line heating: The heating can be set in the range of room temperature -45.0 ℃, and the temperature control accuracy can reach ± 1 ℃, which saves the heating waiting time of the dissolution medium in the dissolution apparatus.
2.3.4 Selection of liquid inlet: The instrument automatically recognizes self-priming or external pressure through the hydraulic detection of the liquid inlet, and automatically switches the flow path to achieve degassing. Customers can connect the liquid inlet to the purified water faucet to operate directly, eliminating the need for The intermediate process is improved, and the work efficiency is improved.
2.3.5 Record : With log function, the operation time of the instrument operation record and other contents are stored in the storage device that comes with the instrument, and can be audited and tracked, and cannot be modified or deleted.
2.3.6 Comply with Chinese Pharmacopoeia 2020 standard for preparation of dissolution medium.
2.3.7 The combination of heating , vacuum and circulation makes degassing more thorough and rapid.
2.3.8 Color touch screen, the parameters are clear at a glance, and the operation is fast and quick.
2.3.9 Equipped with hydraulic detection, which can realize automatic switching between self-priming and external pressure.
2.1 Performance parameters
2.1.1 Heating range : room temperature -45.0 ℃
2.1.2 Temperature resolution: 0.1 ℃
2.1.3 Temperature control accuracy: ± 1 ℃
2.1.4 Flow resolution: 0.1mL
2.1.5 Flow control accuracy: ≤±1 %
2.1.6 Removal rate : ≥85%
2.1.7 Degassing membrane pore size: 300μm OD/220μm ID
2.1.8 Degassing membrane area: 0.58m² ID
2.1.9 Count of hollow fiber membrane: 7400
2.1.10 Porosity: 40% Porosity
2.1.11 Silk film material: Polyurethane
2.1.12 Degassing rate: ≤1000mL/ Min
2.1.13 Vacuum resolution: 0.1K p a
2.1.14 Vacuum degree: ≤ – 90K p a
2.1.15 Target oxygen content: ≤2.8mh /L
2.1.16 Logging function, can audit trail
2.2 Instrument indicators
2.2.1 Input power: 220Vac±10% 1100W
2.2.2 Overall size: 260x530x560mm
2.2.3 Overall weight : 23K g
2.2.4 EMC : IEC6100-4-2 , IEC6100-4-4, IEC6100-4-5, IEC6100-4-11
2.2.5 Operating temperature : 5~40℃
2.2.6 Storage temperature: -20~60℃
2.2.7 Working humidity: 20~80% RH
2.2.8 Storage humidity: 5 ~95% RH
installation requirements
3.1 Environmental requirements
3.1.1 RTD-2010 real – time constant temperature degassing instrument should be placed in a dedicated working space, and there should be no harmful, flammable and corrosive gases nearby.
3.1.2 Operating temperature: The limit working temperature is (5~40) ℃, and the indoor temperature should be ( 15~25 ) ℃ during normal operation.
3.1.3 Storage temperature: (-20~55) ℃
3.1.4 Ambient relative humidity: ( 20 ~80) % RH
3.2 Placement requirements
RTD-2010 real-time constant temperature degassing instrument should be placed in a horizontal, flat and stable position. Because it is a liquid handling instrument, water leakage and splashing may occur. Pay attention to electricity safety; the inlet and outlet of the instrument flow path are on the left side of the instrument There should be at least 30cm space on the side and left side to ensure the experimental operation. The power inlet of RTD-2010 real-time constant temperature degassing instrument is located at the rear of the instrument, please ensure that the distance between the power socket and the inlet is no more than 1 meter.
3.3 Power Requirements
A set of (220±20) V AC, 10A, 50/60Hz, protective grounded single-phase power supply is required to power the instrument; the PE grounding of the power supply must be reliable to ensure the normal operation of the instrument and avoid electric shock to the human body. The grounding resistance of the ground wire is required to be less than or equal to 0.1 ohms.
CS-2 Tablet Friability Tester For Lab Use CS-2 Tablet Friability Tester For Lab Use The Friability Tester is used to test the physical strength of the uncoated tablets such as crushing strength, etc. Features: It has single way and double barrels which circulate at the same time; Timing power off automatically. The cylinder adopts high grade colorless transparent lucite. You can preset the parameter of speed and turn number optionally; timesharing shows the preset value and real-time value. Full-automatic intellectuality control the speed and the turning number of the cylinder with a high control precision. The automation: automatic test, automatic diagnosis, automatic alarm.
TFT-1 Tablet Friability Tester For Lab Use
The Friability Tester is used to test the physical strength of the uncoated tablets such as crushing strength, etc.
It has single way and double barrels which circulate at the same time; Timing power off automatically.
The cylinder adopts high grade colorless transparent lucite.
You can preset the parameter of speed and turn number optionally; timesharing shows the preset value and real-time value.
Full-automatic intellectuality control the speed and the turning number of the cylinder with a high control precision.
The automation: automatic test, automatic diagnosis, automatic alarm.
Quantity of the turnplate cylinder: | 2 |
Interior Diameter of the turnplate cylinder: | Φ286mm |
Depth of the turnplate cylinder: | 39mm |
Sliding height of the drug: | 156mm |
Scope of rotating speed: | 25 circles/min |
Precision of rotating speed: | ±1 circle/min |
Scope of rotating circle quantity: | 100circles |
Precision of rotating circle quantity: | ±1 circle |
Continuous working time: | >24 hours |
Power supply: | 220V 50Hz 40W |
Overall dimension: | 37x30x34cm |
Weight: | 11kg |
Dissolution 1. It can realize the test of basket method, paddle method, small cup method, dish method (large and small dish), and drum method (long and short tube) to meet the requirements of blank and control.
1. It can realize the test of basket method, paddle method, small cup method, dish method (large and small dish), and drum method (long and short tube) to meet the requirements of blank and control.
2. The machine head is electrically lifted.
3. The sampling frame is electrically lifted.
4. Automatically set the clutch.
5. Automatic, independent drug administration.
6. Two-color lighting system.
7. Multi-user management.
8. WiFi, Bluetooth, RS232, RS485 expansion interface.
9. Built-in printer.
101. Solvent monitoring.
11. Stirring speed monitoring.
12. Multi-user management.
13. Connect to the sampler.
15. High sensitivity capacitive touch screen.
16. Rights management.
17. Audit trail.
Technical spec :
Model | MDS-2008DS |
Cup | 8 |
Bath Temperature | RT-45℃ |
Solvent temperature detection | 8 channels |
Temperature resolution | 0.01℃ |
Stirring speed | 25RPM—250RPM |
Stirring speed resolution | 0.1RPM |
Dosing channel | 8 |
Head lift method | Electrical method |
Head lift method | Electrical method |
Sample point resolution | 1ml |
Lighting system | Red ligh/White light |
Number of user | 7 users |
User lever | 3 class |
Progrma | 99 |
Record keeping | 128 items *366 days |
Item 2 Sampling Model no QY8
Description
1. Use a precision glass syringe as the sampling power.
2. 2. Adopt high precision, high pressure and high chemical stability valve body.
3. 3. Built-in micro printer.
4. 4. Multi-user management.
5. 5. WiFi, Bluetooth, RS232, RS485 expansion interface 1.
6. 6. The internal use of high chemical stability of the Teflon pipeline.
7. 7. Has the same amount of rehydration function.
8. 8. With independent pipeline system, it can meet the control requirements of blank and standard for dissolution test.
9. 9. A cylindrical filter head with a pore size of 10 μm was sampled at the initial filtration, and a φ25 mm syringe filter having a pore size of 0.8 μm/0.45 μm/0.22 μm was selected as needed for the secondary filtration.A 11.16-bit test tube rack can hold up to 192 tubes.
10. 10. The sampling tube is equipped with a silicone cap to prevent evaporation and contamination of the sample.
11. 11. Can be operated online with the dissolution apparatus.
12. 12. Ampoule collection device.
13. 13. High sensitivity capacitive touch screen.
14. 14. Rights management.
15. 15 Audit tracking
Technical Spec :
Model no | QY8 |
Sampling channel | 8 |
Sample times | 16 |
Longest sampling interval | 99 hours 59 minutes |
Minimum sampling interval | 1 minute for the first time, 2-10 minutes for the rest |
Continuous working hours | 99 hours 59 minutes × 16 |
Sampling filter period | <30 Second |
Sample volume (or fluid volume) | 1ml—100ml |
Single tube distribution amount | 0ml—15ml |
Sampling accuracy | RSD1%(10ml) |
User program | 99 |
Number of users | 7 users |
User level | 3 class |
Record keeping | 128 items *366 days |
The drug dissolution apparatus MDS-2008DS uses an 8-channel imported syringe pump to realize high-precision, fully automatic dissolution, sampling, replenishment, dilution and other tests. The indicators of the instrument are excellent, and the performance parameters far meet the Chinese Pharmacopoeia, the United States Pharmacopoeia, and the drug dissolution apparatus. Regulations and standards at home and abroad such as mechanical verification guidelines.
Dissolution systemDrug dissolution sampling system Dissolution method; compatible with basket method, paddle method, small cup method, paddle butterfly method and rotating drum method at the same time; Dissolution cup: 6/8 cup can be switched by software to realize isothermal rehydration Stirring shaft: segmented shaft design, only need to replace the basket (paddle) when switching the dissolution method, no need to manually re-adjust the height of the positioning basket (paddle), and quickly switch the dissolution method; only need to adjust the dissolution cup and sampling when switching the small cup method Needle is fine. Photosensitive lighting: with white light and red light illumination, three levels of brightness adjustable, turn off the ambient lighting when the photosensitive drug is dissolved, and turn on the red light. Dosing system: a single dosing system, which can realize simultaneous or sequential dosing, and the interval of sequential dosing can be set. Water bath system: square integrated sink with arc corners, easy to clean; bottom drain, which can be completely drained; ceramic heating tube heating, safe and reliable, and with over-temperature and water shortage alarms. Software systemDrug dissolution sampling system, dissolution program: can store more than one hundred experimental programs, and can be imported and exported via USB, which is convenient for program export and import between instruments. Account: It can store 40 login accounts and passwords, which can be divided into three levels: administrator, advanced user, and operator. The operation authority can be controlled by levels; the administrator can assign and modify the account and password uniformly. Record: Built-in thermal printer, operation records and test data can be printed and saved by the printer; with log function, the instrument operation record can be stored in the storage device of the instrument along with the operation account and operation time, and can be audited and tracked. It can be encrypted and exported when necessary, and cannot be modified or deleted. Alarm system: power-on self-check, operation monitoring, fault diagnosis and isolation and alarm recording functions Reservation function: It can realize the reservation heating function. Basket (paddle) shaft
Model | MDS-2008 |
Water bath heating range | RT-45℃ |
Temperature Resolution | 0.01℃ |
Temperature control accuracy | ≤ 0.2℃ |
Stirring speed range | 25RPM-250RPM |
Speed resolution | 0.1RPM |
Speed accuracy | ≤±0.5RPM |
L basket (paddle) shaft swing amplitude | ≤0.5mm |
Swing amplitude of basket | ≤1.0mm |
Shaft and dissolution cup shaft deviation | ≤1.0mm |
Dissolution instrument levelness | ≤ 0.5 |
Basket (paddle) shaft verticality | ≤ 0.5 |
Dissolution apparatus | 220Vac±10% 1300W |
Dissolution apparatus | 670x600x650mm |
Dissolution apparatus | 65kg |
EMC | IEC6100-4-2,IEC6100-4-4,IEC6100-4-5,IEC6100-4-11 |
1.Feature and Description
It has eight vessels and six poles, with six vessels and six poles in front and other two vessels at back.
The head moves up/down automatically.
The basket units and paddle units are made of imported stainless steel (SUS316L).
The magnetism-pumped circular water current can heat the system evenly, and the bath liquid can achieve an equal temperature.
A MPU is used in dissolution tester to automatically control the temperature, rotational speed and time, and the parameters can be preset at any time.
It can be operated conveniently by keystroke. The measurement result is displayed by LED. The preset and real data can be displayed alternately in time.
Automation: auto-test, auto-diagnose, auto-alarm.
It can test by self and alarm automatically. The dissolution parameters of’ Chinese codex 2010′ are stored in and can be taken out at anytime.
Time can be preset at many points. The beeper sounds automatically to any point, and then the tester automatically runs to the next one.
1、 Performance characteristics
(1) Dissolution instrument part
1. It fully meets the requirements of Chinese Pharmacopoeia and American Pharmacopoeia.
2. Swing amplitude of mixing paddle: ≤ 0.5 mm.
3. Dissolution speed: 10 ~ 300rpm, speed accuracy: ± 0.5rpm, speed resolution 0.1 rpm.
4. The dissolution instrument is equipped with 14 cups and 14 paddles, two of which are independent isothermal rehydration cups. The compatible design of large cup method and small cup method can be switched quickly, and the operator can operate simply.
5. The dissolution cup adopts embedded fixed hoop design to achieve better centering and verticality of the dissolution cup. The cup edge is designed with an indicator strip and a diagonal fixing device to achieve higher reproducibility. 1000ml and 250ml specifications are available, and the dissolution cup can be selected as transparent or low photochemical Brown products for photosensitive substances.
6. There is no joint inside the water tank, with round corner design, bottom slope drainage, and standard quick adapter, which is convenient for rapid emptying and cleaning.
7. ★ through the segmented propeller shaft design, 316L medical grade stainless steel material, the paddle method and basket method can be quickly switched without re setting the height. The small cup method, paddle disc method and rotary drum method can be quickly switched through simple height setting tools.
8. ★ equipped with two groups of independent rotating shafts, the speed of the two groups of experiments can be controlled independently. Double 4 cup, double 5 cup, double 6 cup and double 7 cup parallel comparison experiments and single 4, 5, 6, 7, 8, 10, 12, 14 cup experiments can be done to increase the flexibility of the experiment.
9. The corresponding positions of dissolution cup, paddle, basket and other accessories are laser marked to avoid mechanical errors caused by accessories with different cup numbers.
10. ★ the machine head operates stably and always remains horizontal, and the height difference between the left and right is ≤ 1mm. The left and right symmetrical silent large torque double lifting and lowering columns are used to ensure that the center of gravity of the machine head is centered and stable, and the electronic monitoring function of levelness is provided, which can be displayed in the operation interface in real time, with the locked rotor detection function, and the alarm prompt when the lifting state is abnormal.
11. Equipped with an independent anti-evaporation lid which rises and falls synchronously with the nose to effectively prevent the influence of longtime experiment solution evaporation. The lid rises synchronously before experiment to facilitate the operator to add liquid and other operations. The lid can be automatically centered with the dissolving cup to achieve better closing effect. ★ the bottom plate and the head bottom plate are made of aluminum alloy lightweight material, which has high hardness, deformation resistance and corrosion resistance. The pipelines are made of imported acid and alkali resistant PP, TPE, PTFE and other engineering plastics and 316L stainless steel, which have good corrosion resistance and adsorption resistance.
12. The nonresident sampling needle and temperature probe are designed to automatically drop when sampling and automatically rise after sampling, so as to reduce the influence of the interference of the dissolved medium on the experiment.
13. ★ it has the manual sampling function of automatic height setting of the sampling rack. The sampling height is automatically calculated according to the dissolution procedure, without manual positioning. It is equipped with a manual sampling auxiliary device to realize convenient and fast manual sampling. The manual sampling point has a voice reminder function, which is convenient for the operator to prepare for sampling in advance.
14. It adopts independent rotary dosing, which can realize integrated dosing and sequential dosing. It has the function of customized dosing stop time. The dosing time point can be recorded and tracked by the system. It has anti sticking design, which is convenient for disassembly and cleaning.
15. PT1000 temperature sensor is adopted, which has small temperature drift, high temperature stability and fast response speed. The temperature resolution reaches 0.1 ℃.
16. ★ a 10.1-inch color touch screen is used for human-computer interaction. When dissolution sampling is used in conjunction, the sampling instrument can be set and used uniformly only by a single human-computer interaction interface of the dissolution instrument. The sampling instrument does not need an independent operation interaction interface to improve the integrity and convenience of operation.
17. Support switching between Chinese and English. The main operation interface can display the instrument operation status, log information, instrument alarm reminder information, program parameters, user list, etc. The screen is equipped with a protection mechanism for operators to leave to prevent others from touching it by mistake.
18. ★ provide four levels of management authority that meets the requirements of audit tracking, which can be divided into super administrator, administrator, senior user and operator, and can control access and prevent unnecessary instrument settings or method changes.
19. ★ the instrument needs to be equipped with group management function, which can realize the different operations of multiple groups with the same instrument. The user and program parameter settings between groups do not interfere with each other, and meet the audit tracking requirements. It can store no less than 57 login accounts and passwords, and the operation authority is controlled by levels.
20. The instrument is equipped with an independently controlled heating cycle system and has the function of unattended reservation.
21. The instrument is equipped with a micro printer as standard, which can print operator information, operation experimental program data, temperature and actual speed information of each sampling point. The experimental data and all operations of the system record log information in real time. The log information has an encryption and upgrade tracking system, and can export data through USB port. The exported data cannot be modified, which meets the requirements of audit tracking.
22. ★ the instrument can store 144 experimental methods, and the instrument methods can be imported and exported through USB one key, avoiding the cumbersome steps of method transfer between different instruments.
23. ★ the instrument has a built-in voice reminder, which can give voice prompts in Chinese (English can be selected) during program operation, instrument reminder and instrument alarm to assist users in operation.
24. ★ the instrument has heating over temperature alarm, liquid leakage detection and motor locked rotor alarm. It can set the water bath temperature difference excess alarm, solvent temperature difference excess alarm, mixing speed excess alarm and water bath heating timeout alarm.
25. The manufacturer provides AIQ certification services, mechanical verification services, instrument training, installation site training and other technical and application related support services that meet the standards.
(2) Sampler section
1. The sampler adopts the automatic door opening mode, and the sampling rack enters and exits the warehouse with one key. The sample rack meets the rapid switching of 2ml liquid phase bottle and 10ml test tube (224) methods, with a maximum number of 16 sampling times. It has a dual sampling mode to achieve a maximum sampling volume of 20ml.
2. The sampling accuracy error is less than ± 0.8%.
3. ★ The sample holder adopts the design of easy to take out and place, and has the function of detection of installation in place, detection of leakage and abnormal protection, which effectively reduces the harm caused by Improper operation.★ the liquid tank side of the sampler adopts a pull-out design, which facilitates the cleaning operation of the liquid tank after long-term use, and there is no need to disassemble and reinstall the pipeline. The liquid tank has the function of up and down liquid level detection to ensure that there is no lack of liquid and no overflow.
4. It can automatically calculate the sampling height, and can accurately sample at the position in line with the provisions of the Pharmacopoeia according to the solvent volume at the sampling time;
5. The sampler is equipped with two-stage filtration, and the initial filtration is 10μM pore diameter cylindrical filter head, secondary filtration can be selected as unfiltered or 0.8 according to actual needsμm/0.45μm/0.22μM aperture needle filter.
6. ★ high precision imported syringe and multi-channel integrated drive structure are adopted to improve the consistency of multi-channel sampling and reduce the dead volume of injection pipeline. The dead volume of each injection pipeline is ≤ 0.15ml.
7. ★ the sampler provides at least 3 multi angle transparent observation windows, which is convenient for the operator to observe the real-time state of the syringe pump and sample rack during the experiment.
8. Continuous sampling, double sample sampling, automatic sample dilution and other functions are available. The first interval is 1 minute and 20 seconds.
9. The instrument has its own program parameter setting limits. If the sampling volume and dilution volume exceed the maximum volume of the selected container, it will be automatically modified to the maximum value that can be used; The sampling time interval is automatically calculated, and the alarm reminder of too small interval is set. Check the program parameters before operation to avoid experiment failure or instrument damage caused by operator error.
10. ★The head runs stably and keeps level all the time. The height difference between left and right is less than or equal to 1mm. The symmetrical and mute large torque double lifting column ensures that the center of gravity of the head is in the middle and stable.
11. The sampling has the function of automatic isothermal and equal fluid replenishment.
12. Sampling volume: 1ml ~ 10ml (single time), 2ml ~ 20ml (double sampling).
1.Dissolution apparatus
project | index |
Instrument performance index | Number of dissolution cups: 14 |
Heating range of water bath: room temperature -45.0 ℃ | |
Temperature resolution: 0.1 ℃ | |
Temperature control accuracy: ± 0.2 ℃ | |
Mixing speed range: 10.0-300rpm | |
Speed resolution: 0.1rpm | |
Speed accuracy: ± 0.5rpm | |
Heating over temperature alarm: Yes | |
Night leakage alarm: Yes | |
Motor stalling alarm: Yes | |
Excessive temperature difference alarm of solvent: Yes | |
Water bath temperature difference excess alarm: Yes | |
Water bath heating excess alarm: Yes | |
Excessive mixing speed alarm: Yes | |
Intelligent voice reminder: Yes | |
Network interface: 100M RJ45 | |
Display size: 10.1 inches | |
Permission setting: Level 4 | |
Number of accounts: 57 | |
Number of methods: 144 | |
Swing amplitude of propeller shaft: ≤ 0.5mm | |
Swing amplitude of basket: ≤ 1.0mm | |
Concentricity between basket (paddle) shaft and dissolution vessel | |
Propeller rod symmetry: ≤ 0.5mm | |
Levelness of dissolution instrument: 0.5 ° | |
Height difference between the left and right of the machine head: ≤ 1mm | |
Perpendicularity of propeller shaft and blade: 90 ° ± 0.2 ° | |
Inner diameter deviation of dissolution cup (cylindrical part): ≤ 0.5mm | |
working temperature | (5~40) ℃ |
Storage temperature | (-20~60) ℃ |
Working humidity | (20~80)% RH |
Storage humidity | (5~95)% RH |
2. Sampler
project | index |
performance parameter | Number of sampling channels: 14 |
Single sampling volume: 0.1-10ml (single); 0.2-20ml (double) | |
Sampling times: 1-16 times (single); 1-8 times (double) | |
Number of samples: 224 | |
Sampling accuracy: ≤ 0.8% (10ml sampling) | |
Minimum sampling interval: 1 minute 20 seconds | |
Automatic dilution accuracy: ± 1% | |
Temperature control accuracy of fluid infusion: ≤± 0.5 ℃ | |
Primary filtration: 10μM cylindrical filter head | |
Secondary filtration: 0.8μm/0.45μm/0.22μM needle filter | |
Dead volume of injection pipeline ≤ 0.15ml | |
Maximum working time: Unlimited | |
Automatic calculation of sampling height: Yes | |
Isothermal rehydration: Yes | |
Visual observation window: 3 | |
Control interface: RS422 | |
Instrument function | Automatic moistening, filling, dropping, sampling, replenishment, dilution, emptying and cleaning |
Precise sampling by syringe pump, and the suction stop time can be set | |
working temperature | (5~40) ℃ |
Storage temperature | (-20~60) ℃ |
Working humidity | (20~80)% RH |
Storage humidity | (5~95)% RH |
1.※The dissolution vessel is designed with embedded fixing hoop to achieve better centering and verticality of the dissolution vessel. Indicator strips and diagonal fixtures are designed on the cup rim to achieve higher reproducibility. Available in 1000mL and 250mL specifications, and the dissolution vessel can be either transparent or low actinic red for photosensitive substances.dissolution drug tester
Model no:MDS-2008DS dissolution drug tester
1.Parameters
1. ※The dissolution vessel is designed with embedded fixing hoop to achieve better centering and verticality of the dissolution vessel. Indicator strips and diagonal fixtures are designed on the cup rim to achieve higher reproducibility. Available in 1000mL and 250mL specifications, and the dissolution vessel can be either transparent or low actinic red for photosensitive substances.
2. The V-cup cover is designed to fit well with the dissolution vessel, which can reduce solvent evaporation.
3. an automatic dosing module that avoids tablet sticking, enabling simultaneous and sequential dosing.
4. ※The one-piece injection-molded water bath box with quick adapter as standard, there is no bonding in the box, and there is no dead angle area such as right angle.
5. ★ It adopts segmented 316L stainless steel propeller shaft design. When replacing, only the lower propeller shaft is required to be replaced, and the whole root is not disassembled, which reduces the workload of re-setting the height after replacement.
6. ★ The machine head adopts multi-point stainless steel guide rod to ensure the stability of the machine head and effectively prolong the stable time of mechanical performance.
7. ※ A color touch screen of no less than 10 inches is used for human-computer interaction , which can realize the setting, storage and operation of no less than 100 methods. With screen lock security function, it also provides Chinese and English bilingual operation interface.
8. Provides three levels of administrative privileges compliant with audit trail requirements to control access and prevent unnecessary changes to instrument settings or methods.
9. The instrument is equipped with an independently controlled heating cycle system with an unattended reservation function.
10. The instrument has eight independent temperature probes, and the temperature of the eight cups of solvent is independently monitored and displayed in real time. The temperature control method should adopt PID+fuzzy control, the temperature control accuracy should not be lower than ±0.2℃, and the temperature resolution should reach 0.1℃.
11. The instrument should have a built-in printer, which can print and save experimental data in real time.
12. The instrument has built-in photosensitive lighting, and with the brown dissolution vessel, light-proof experiments can be realized.
13. ※The instrument can store 100 experimental methods, and the instrument methods can be imported and exported through one-key USB operation, avoiding the tedious steps of method transfer between different instruments.
14. Manufacturers provide standard-compliant AIQ certification services, mechanical verification services, and technical and application-related support services such as instrument training and installation on-site training.
15. ※The sampler is equipped with an automatic door opening device, which can realize one-key entry and exit of the warehouse.
16. It can automatically calculate the sampling height, and at the sampling time, it can accurately sample the position in line with the Pharmacopoeia according to the volume of the solvent;
17. There should be a secondary filter interface to make the impurities filter more fully.
18. ★ The instrument adopts imported syringes, which can realize the steps of automatic rinsing, filling, waste drop disposal, sampling, replenishment, and emptying, etc., to ensure the sampling accuracy, and to ensure that the pipeline residue is as little as possible.
19. The instrument adopts imported PTFE micro-transparent pipeline, which has anti-corrosion and anti-adsorption properties.
20. ★ Continuous sampling, dual sample sampling, automatic sample dilution and other functions, the shortest sampling interval is 2 minutes
21. The pipeline and sampling pump are automatically rinsed before sampling to ensure the accuracy of sampling samples.
22. After the experiment is completed, one-click automatic cleaning of the liquid tank and pipeline ensures no cross-contamination.
23. ★ The product can provide professional third-party testing report on product performance.
1. Dissolution Apparatus
project | index |
Instrument performance index | Water bath heating range: room temperature -45. 0 ℃ |
Temperature Resolution: 0.1 ℃ | |
Temperature control accuracy: ±0.2 ℃ | |
Stirring speed range: 25.0-250.0 RPM | |
Speed Resolution: 0.1 RPM | |
Speed Accuracy: ±0.5 RPM | |
Instrument mechanical indicators | Basket (paddle) shaft swing amplitude: ≤0.5mm |
Basket swing range: ≤ 1.0 mm | |
rotating shaft and the dissolution vessel shaft: ≤ ± 1.0mm | |
Dissolution apparatus horizontality: 0.5° | |
Basket (paddle) axis verticality: 0.5° | |
Dissolution vessel verticality: 1.0° | |
Instrument function | Compatible with basket method, paddle method, small cup method, paddle butterfly method, rotating drum method |
Number of dissolution vessels: 6/8 cups | |
Segmented shaft design, no need to manually re-adjust the height of the positioning basket (paddle) when the dissolution method is switched. | |
Automatic simultaneous dosing/sequential dosing | |
Photosensitive lighting: white light/red light three-level lighting | |
Can store 100 experimental methods, and can import and export USB | |
It can store 39 login accounts and passwords, and the operation authority can be controlled in 3 levels | |
With operation record printing and log recording function, and can audit trail | |
input power | 220Vac ± 10% 1300W _ |
Overall size | 670*565*640(W×D×H) |
Total Weight | 6 5kg _ |
Operating temperature | (5~40) ℃ |
storage temperature | (-20~60) ℃ |
Working humidity | (2 0 ~ 80) % RH |
Storage humidity | (5~95) % RH |
2. Sampler
project | index |
Performance parameters | Single sampling volume: 0.2-15mL (single); 0.4-30mL (double) |
Sampling times: 1-16 times (single); 1-8 times (double) | |
Sampling accuracy: ≤0.8% (10mL sampling) | |
Sampling rack: 2ml liquid phase injection bottle * 128 or 1 5 ml test tube * 128 | |
Instrument function | Fully automatic rinsing, filling, dripping, sampling, replenishment, dilution, emptying, cleaning |
Precise sampling by syringe pump, suction and stop time can be set | |
input power | 220Vac ± 10% 200W |
Overall size | 515*660*460mm(W×D×H) |
Total Weight | 35Kg |
Operating temperature | (5~40) ℃ |
storage temperature | (-20~60) ℃ |
Working humidity | (20~80) % RH |
Storage humidity | (5~95) % RH |
Features: 1.Automation: auto-test, auto-diagnose, auto-alarm. 2.Intelligently control the rotating speed of cylinder and revolutions. 3.One drum runs synchronously. Auto stop at timing point. (only for TFT-4) 4. Single path and double cylinder, synchronous operation and automatic stop. 5.The revolution of the drum can be preset at any time, either preset or real data is displayed on the LCD. 6. Microprocessor unit is used to control all operations, high accuracy is achieved in testing rotary speed and circle number.
Digital Friability Test Apparatus is a precision instrument suitable for measuring obression strength of tablets.
The unit is equipped with two transparent acrylic drums which rotate at a speed of 25 ± 1 RPM.
Each of the two acrylic drums are provided with an arm which carries the tablets along with it up to a predetermined height and allows them to fall from that specified height, while the drums are rotating,
It is fitted with a digital revolution counter showing the current number of revolutions for the test.
A thumb wheel switch is used to set the desired number of rotations.
Provision is made to remove the lid of the acrylic drum by unscrewing just one knob. This is available in 1 drum and 2 drum assemblies.
Parameter
Applicable standards: Corporate standard(Tablet hardness tester )Q/12XQ0186-2010
Tablet hardness testers are instruments for detecting breaking hardness of tablet.
Applicable standards:
Corporate standard(Tablet hardness tester )Q/12XQ0186-2010
Features:
The tablet is loaded artificially and pressed automatically.
There is high accuracy press sensor and hardness data is displayed on LED.
It tests tablet hardness continuously. The biggest number is 100 pieces of a gang.
Time of testing will be saved by directly measuring the diameter.
Test data is displayed and locked automatically, so can test be reset and cycled.
It can deal with and print out such data as: hardness of each tablet, the maximum value, the minimal value, the average value and the number of tablets.
The parameters can be preset at any time. Either preset or real data is displayed on the LED.
Automation: auto-test, auto-diagnose, auto-alarm.
Specifications:
◎Hardness range (2~199.9)N
◎Hardness accuracy Max. *(±0.05%)
◎Probe procession range (3~40)mm
◎Test period 20S/P
◎Max number in each group 100P
◎Power 220V/ 50Hz/ 60W or 110V/ 60Hz/ 60W
◎Dimension (500*300*160)mm3
Tablet hardness testers are instruments for detecting breaking hardness of tablet.
Applicable standards:
Corporate standard(Tablet hardness tester )Q/12XQ0186-2010
Features:
The tablet is loaded artificially and pressed automatically.
There is high accuracy press sensor and hardness data is displayed on LED.
It tests tablet hardness continuously. The biggest number is 100 pieces of a gang.
Time of testing will be saved by directly measuring the diameter.
Test data is displayed and locked automatically, so can test be reset and cycled.
It can deal with and print out such data as: hardness of each tablet, the maximum value, the minimal value, the average value and the number of tablets.
The parameters can be preset at any time. Either preset or real data is displayed on the LED.
Automation: auto-test, auto-diagnose, auto-alarm.
Specifications:
◎Hardness range (2~199.9)N
◎Hardness accuracy Max. *(±0.05%)
◎Probe procession range (3~40)mm
◎Test period 20S/P
◎Max number in each group 100P
◎Power 220V/ 50Hz/ 60W or 110V/ 60Hz/ 60W
◎Dimension (500*300*160)mm3
MDS-2008 fully complies with the regulations of the National Pharmacopoeia 2020 and is a brand-new instrument launched by Ningbo Scientz Biotechnology for high-end pharmaceutical companies, drug testing centers, and scientific research units.
The product performance indicators (speed accuracy, single sampling volume, sampling accuracy, shaft deviation) have reached or exceeded similar imported brands.
Advantages of MDS-2008Dissolution Testing Equipment:
In order to extend the service life of the instrument and improve the performance and quality, MDS-2008 has been upgraded in hardware configuration:
1.One-time injection molding water tank, anti-cracking, slope drainage combined with rounded corner design, sanitary and no dead corners, easy to clean; |
2. The independent diagonal fixing device of the dissolution cup, the silicone cup ring and the V-shaped cup cover, realize the double sealing of the line and the surface, and greatly reduce the evaporation of the solvent; |
3. 316L stainless steel paddle rod, using MPT stainless steel mirror polishing technology to reduce bacterial adhesion; |
4. Segmented propeller shaft design, when changing the dissolution method, there is no need to re-set the height, which is convenient and quick; |
5. Multi-point stainless steel guide rods to ensure long-term stability of the machine head vertical and mechanical performance indicators; |
6. The external dosing device is easy to clean and prevents cross-contamination; |
7. 10-inch large LCD touch screen, easy to operate; |
8. The fully automatic sampling tray with automatic positioning and in-position detection reduces manpower and prevents interruption of operation due to human reasons; |
9. The ultra-high-precision micro-injection tube imported from Germany is used to ensure the accuracy when the extraction volume is low; |
10. Equipped with an integrated mechanical verification function package. |
Software is the brain that controls the movement of the instrument. The excellent software control center of the MDS-2008 tablet dissolution tester makes the product performance to the fullest:
|
|
|
|
|
Dissolution testing is a requirement for all solid oral dosage forms and is used in all phases of development for product release and stability testing;The tablet dissolution test apparatu is a key analytical test used for detecting physical changes in an active pharmaceutical ingredient (API) and in the formulated product.
Tablet dissolution apparatus principle
It can simulate the gastrointestinal conditions and digestive processes in the human body, and detect all aspects of the data of pharmaceutical preparations.
Tablet dissolution test apparatus use
This dissolution apparatus is usually considered in product development for controlled release preparations. The reason for this is to aid the release of products in GI tracts by exposing them to various physicochemical conditions and mechanical conditions.
Tablet dissolution test apparatus price
Different configurations have different prices. For example, the price of a sampler with and without a sampler is very different. The price of a single dissolution apparatus is cheap, and the factory price
Types of tablet dissolution apparatus
There are seven USP-defined types of dissolution apparatus: baskets, paddles, reciprocating cylinders, flow through cells, paddle over disk types, cylinders, and reciprocating holders.
Why dissolution test is important?
Dissolution testing has emerged as a very important tool in the generic pharmaceutical industry. It is very widely used in formulation development, in monitoring the manufacturing process and as a quality control test. It can also be used to predict the in vivo performance of certain products.
Tablet disintegration apparatus are used to test how a drug in pellet form will disintegrate in solution. Disintegration testers help in evaluation of disintegration capability of formulations (ex: tablets) and quality control of different dosage forms in pharmaceutical companies.
The mechanism of tablet disintegration:
① Mechanism of forming corrosive pores: Soluble ingredients contained in the tablet dissolve quickly after contact with water to form corrosive pores.
② Solid bridge fracture mechanism: After water penetrates the tablet, the “solid bridge” dissolves and the binding force disappears.
③ Gas generation mechanism: The tablets containing effervescent disintegrants produce CO2 gas when they encounter water.
④ Water absorption and swelling mechanism: The disintegrant swells with water, the volume of editing and finishing increases, and the binding force of the tablet is destroyed.
⑤ Moist heat mechanism: The tablet absorbs water and produces moist heat, which is the expansion of the air in the tablet.
Pharmaceutical tablet dissolution testers are used for detecting velocity and extent of pharmic dissolution from tablet, capsule etc in prescriptive menstruum.
1. Automation :Auto-set ,auto=diagnose ,auto-alarm.
2. Time can be preset at many points ,The beeper sounds automatically to any point ,and then the tester automatically runs to the next one .
3.Accessories like paddles,baskets and vessels are laser marked with serial numbers for traceability
4.Water bath temperature range between 20℃ to 40℃(upto 55℃ optional)with an accuracy of ±0.1℃
5.Isolated water circulating pump for precise temperature control of the water bath
The 14 station dissolution tester are the most efficient dissolution instruments in the market,specially designed with the end user in mind. They are simple to operate with features that make analyst training and lab integration easy.
The dissolution apparatus are not only ideal for manual testing but can be easily integrated with our automated systems.
1. It has eight vessels and six poles, with six vessels and six poles in front and other two vessels at back.
2. The basket units and paddle units are made of imported stainless steel (ss316L)
3. The magnetism-pumped circular water current can heat the system evenly ,and the bath liquid can achieve an equal temperature.
4. It can be operated conveniently by keystroke, The measurement result is displayed by LED ,The preset and real data can be displayed alternately in time .
The 8 station tablets dissolution tester uses Intuitive 7″ TFT touch-screen graphic display, the operation interface is simple and clear, the instrument has 6 main accounts, 5 secondary accounts, the initial password needs to be changed to a new password for the first time. You can set the fingerprint to unlock, adjust the height of the pulp with the positioning ball, add the water, set the time, temperature, speed, volume, and the instrument can run the instrument. Instrument accessories like paddles, baskets and vessels are laser marked with serial numbers Don’t misplace the position.
Technical indicators:
Application: It is used for detecting friability/abrasion of tablet.
Features:
1.Automation: auto-test, auto-diagnose, auto-alarm.
2.Intelligently control the rotating speed of cylinder and revolutions.
3.One drum runs synchronously. Auto stop at timing point. (only for TFT-4)
4. Single path and double cylinder, synchronous operation and automatic stop.
5.The revolution of the drum can be preset at any time, either preset or real data is displayed on the LCD.
6. Microprocessor unit is used to control all operations, high accuracy is achieved in testing rotary speed and circle number.
Parameter
Model | TFT-1 | |||||
Cylinder Number | 2 | 1 | ||||
Cylinder Radius | Φ286 | |||||
Cylinder Depth | 39mm | |||||
Tablet Fall Height | 156mm | |||||
Rotating Speed | 20~100rpm | 25 rpm | ||||
Rotation Count | 5~900 turns | 100 turns | 5~900 turns | 20-900 turns | ||
Consumption | 40W | 20W | 40W | |||
Power Supply | AC110 /220V±10%, 50/60Hz | |||||
External Size (W*D*H) mm | 370*300*340 | |||||
Package Size(W*D*H) mm | 440*400*525 | |||||
Gross Weight (kg) | 12 |
YD-35 tablet hardness tester is a kind of drug testing instrument for measuring tablet hardness and diameter. With power-on self-test function, measurement range is 0-350N, resolution is 0.1N, can output higher measurement accuracy. Widely used in pharmaceutical factories, drug inspection institutes and related scientific research units. The instrument fully complies with the requirements of the 2015 Chinese Pharmacopoeia.
• Using a single-chip computer to control the operation interface, which is convenient and quick to use.
• High-precision pressure sensor is used to ensure high measurement accuracy.
• Display uses LCD display, Chinese or English interface is optional.
• Statistics, analysis, printing, and display of measurement data can be automatically performed.
• With real-time calendar clock function, the test and calibration date and time can be printed in the test report.
• With fault self-diagnosis function, it automatically prompts for some abnormal phenomena in the test.
• Parameter settings are automatically saved until reset.
• With calibration function, display and print the calibration results.
• Display: 5 inch capacitive touch screen
• Interface: Centronic standard serial printing interface, which can be connected to micro printer (Chinese or English output).
R232 serial port, can be connected to the balance
• Measurement range: hardness 0 ~ 350N, resolution 0.1N;
• Measuring diameter range: 2.0 ~ 25.0mm, resolution 0.01mm;
• Measurement unit: hardness N / Kg / Sc (optional)
Diameter mm / inch (optional)
• Measuring method: manual single piece / automatic continuous (maximum number of pieces is 100 pieces) / optional
ZBJ01 intelligent disintegrator is a new type of instrument designed in accordance with the requirements of the Chinese Pharmacopoeia. it’s a very ideal drug test instrument.
1. 3 baskets disintegration time limit detection system
Model | ZBJ01 |
Temperature Range | RT-45℃ |
Temperature Resolution | 0.01℃ |
Number Of Gondola | 3 |
Lifting Frequency | 30-32 times / minute |
Lifting Distance | 55mm±1mm |
Distance between screen bottom and cup | 25mm±2mm |
Screen mush Aperture | 2mm Optional 1mm, 0.71mm, 0.42mm |
Stop Density | 1.18-1.20g/c㎡ |
Amount Of Users | 7 |
User Level | 3 |
Record | 96 articles * 366 days |
Dissolution apparatus is a microcomputer-controlled mechatronics test equipment for dissolution measurement
Put a certain amount of a certain preparation into the basket (dissolution cup) of the dissolution apparatus, operate at a constant temperature of 37 ° C ± 0.5 ° C, operate according to the specified speed and dissolution medium, sample and determine the dissolution in a specified time. the amount.
1.It can realize the test of basket method, paddle method, small cup method 1, dish method (large and small dish), and drum method (long and short tube), which meets the requirements of blank and control.
2. Machine head electric lift
3. Automatic constant clutch
4. Simultaneous administration and sequence administration
5. Multi-user management
6. Authority management
7. Audit trail
Dissolution: refers to the rate and extent to which a drug is dissolved from a solid preparation such as a tablet in a predetermined solvent. Dissolution is an important indicator of tablet quality control, and poorly soluble drugs should generally be tested for dissolution. For formulations that check for dissolution, the time limit for disintegration is not checked.
The dissolution tester consists of a cabinet, control system, electrical system, water bath system, transmission system, sensors, paddle components, and basket components.
High-precision tablet disintegration instrument complies with the new version of the Pharmacopoeia and is widely used in pharmaceutical companies, drug testing institutes, etc
Model | ZBJ01 |
Temperature range | Room—45℃ |
Temperature resolution | 0.01℃ |
Number of baskets | 3 cups |
Lifting frequency | 30-32 times / minute |
Lifting distance | 55mm±1mm |
Screen bottom distance from the bottom of the cup | 25mm±2mm |
Screen aperture | 2mm Optional 1mm, 0.71mm, 0.42mm |
Stop density | 1.18—1.20g/c㎡ |
Amount of users | 7 users |
User level | Third level |
Record saving | 96 *366 days |
The smart tablet hardness tester is a drug test instrument for measuring the hardness of a tablet. Tablets should have suitable hardness to avoid breakage or wear during packaging and transportation. Therefore, tablet hardness is an important indicator reflecting the level of tablet production technology and controlling the quality of tablets. Correctly reflecting and testing the hardness of the tablet has important practical guiding significance for the production and research of the tablet and the accuracy of the clinical drug.
Performance characteristics:
1. Interface two-wire redundancy design
The 10 interface adopts two-wire parallel design to ensure stable and reliable operation under the condition that 50% of the terminals are connected.
Function parameter
1. High sensitivity capacitive touch screen
2. Authority management
3. Audit trail
Amount of users | 7users |
User level | Third level |
Record saving | 128 *366 days |
RQ810S is composed of RC810S dissolution tester connected to QY8 sampler. It has granule dosage, solvent temperature monitoring, automatic sampling point, and 30 seconds filtration capacity greater than 10ml. Its performance indicators are in full compliance with the requirements of the Chinese Pharmacopoeia (2015 edition) and the “Guidelines for Mechanical Calibration of Dissolution Testers“.
Refers to the rate and extent to which active pharmaceutical ingredients are dissolved from a formulation such as a tablet, capsule or granule under specified conditions. It is an indicator for evaluating the quality of oral solid preparations of drugs, and is an in vitro simple test method for simulating disintegration and dissolution of oral solid preparations in the gastrointestinal tract.
Dissolution assay
Place a certain amount of a certain preparation in the basket (dissolution cup) of the dissolution apparatus, operate at a constant temperature of 37 ° C ± 0.5 ° C, operate at a specified speed and dissolution medium, sample and determine the dissolution within a specified time. the amount.
Providing a mechatronics test device controlled by a microcomputer for dissolution measurement, mainly composed of an electric motor, a thermostat, a basket, a stirring paddle, a dissolution cup and a cup cover
RC810G Dissolution tester
Model | RC810G |
Number of experimental devices | 8 |
Water bath temperature | Room temperature—45℃ |
Temperature resolution | 0.01℃ |
Stirring speed | 25RPM—250RPM |
Stirring speed resolution | 0.1RPM |
Dosing channel | 8 |
Head lift | electric |
Lighting system | Red light, white light |
amount of users | 7users |
user level | Third level |
User program | 99 |
Record saving | 128 *366 days |
QY8 Sampler
Model | QY8 |
Sampling channel | 8 |
Number of samples | 16 |
Longest sampling interval | 99 hours 59 minutes |
Minimum sampling interval | 1 minute for the first time, the remaining 2-10 minutes (depending on the sample size, sampling method and whether it is rehydration) |
Continuous working time | 99 hours 59 minutes × 16 |
Sampling filter cycle | <30 seconds |
Sample volume (or fluid volume) | 1ml—100ml |
Single tube distribution | 0ml—15ml |
Sampling accuracy | RSD1%(10ml) |
User program | 99 |
amount of users | 7 users |
user level | Third level |
Record saving | 128 *366 days |
Intelligent Hardness Tester
Features:
1. Interface double line redundancy design
IO interface is designed in parallel with two lines, ensure stable and reliable operation in the case of 50% terminal virtual connection.
2. Built-in audit tracking
It can store operations including but not limited to starting up, user login, user exit, changing parameters, changing Settings, starting test, completing test, terminating test, etc.
3. 100% Aging test
To ensure the product quality, 48-hour aging test is conducted 100% before delivery.
4. Provide 3Q service
Parameters
1. High sensitivity capacitive touch screen
2. Authority management
3. Audit trial
Technical indicators
Number of users | 7 |
User level | 3 |
Recording keep | 128*366 days |
TQ01 Degassing apparatus was developed according to the Chinese pharmacopoeia, which is used for the degassing with water in the early stage of the measurment of dissolution and releasing rate of solid preparation. The apparatus adopts degassing membrane to degassing, and adopts Dc brushless vacuum pump and water pump, with the advantages of good degassing effect and low noise, the degassing and heating of pure water also can be completed.
Features:
1. Membrane filtration degassing method
The filtration membrane adopts special materials, the filter aperture is as low as 0.01μm~0.2μm, single membrane filtration area can be reached 15㎡,degassing rate can be reached 95% and high filtration efficiency.
2. Handheld sample gun
Patented technology、tape terminal display、controlled sample gun. It can set parameters of velocity 、volume etc. not only on the mainframe but also on the sample gun,it’s convenience to use.
3. Biometric identification technology
Capacitive fingerprint recgnition system can recognize the user’s identity,avoiding the user name password login tedious,easy to use.
4. PWM heating control
Adopt PWM heating control technology,zero-cross SSR and mechanical relay composite control, it not only avoids the interference and reduction of service life caused by switching on and off of single mechanical relay at the wave peak, but also ensures the leakage of power of single solid state relay.Safer and more reliable.
Parameters:
1. The filter membrane degasses online and has high efficiency.
2. Micro – dc brushless vacuum pump,the negative pressure value can reach to 98Kpa, low noise、long service life.
3. Micro-dc brushless regulate integrated miniature water pump, unpulsation of water、real-time traffic feedback、low noise、long service life.
4. Low power high efficiency heating system, adopt normal AC220V10 power interface.
5. Handheld 、adjustable flow sample gun.
6. Electronic scale quantitative system,high quantity accuracy.
7. Multi-user management.
Technical indicators
Vacuum degree | 98Kpa (highest) |
Velocity regulating | 30%-100% |
Heating power | 1500W |
Volume of quantitative | 15L |
Quantitative accuracy | 10L±1% |
Number of users | 7 |
User level | 3 |
User program | 99 |
Recording keep | 128*366 days |
Dissolution Sampling System
Features:
1. 26ml high precision and high pressure PEEK head syringe
The patented technology can realize the effective sampling amount of 20ml at a single time, and it can withstand the pressure of 0.4mpa, and filter the viscous samples without leakage. PEEK heads are more resistant to corrosion than metal heads, and there is no risk of side leakage.
2. Torque matching technology multi-channel lifting frame
Patent technology, more than syringe thrust has been solved by the moment matching technology is different, caused by the eccentric, eccentric wear, out of sync, and so on and so forth, effective use of the power, prolong service life, improve the consistency.
3. High precision three-phase stepper motor is used for sampling
The stepping Angle of only 1.2 °, cooperate with the ball screw, higher precision.
4. Multiple way rotary valve
It is simpler than solenoid valve, less quantity, small dead volume, good synchronism and pressure resistance of 0.4mpa.
5. Full flanging line
All pipelines adopt the flanging design to avoid the reduction of the sectional area caused by the conical sleeve connection and the inability to repeatedly disassemble and install, while ensuring the sealing.
6. Ptfe piping
The pipeline adopts polytetrafluoroethylene material, which has good corrosion resistance and strong adsorption resistance.
7. Secondary filtrate retention function
The initial filtrate is discarded, and the remaining sample of the continuous filtrate is used for treatment, which fully conforms to the manual sampling operation process and can solve the adsorption problem.
8. AFR250 cable
By using pure copper wire, silver plated AFR250 ptfe 250 ℃ heat resistance, toughness, low resistance, avoid the long-term use of ageing problems.
9. Tube cap
It can effectively prevent evaporation and cross contamination.
10. Ampoule bottle collection system
The universal ampoule bottle collection system of waters and agilent can be directly used for liquid phase detection.
11. Biometric identification technology
Capacitive fingerprint recgnition system can recognize the user’s identity,avoiding the user name password login tedious,easy to use.
12. Built-in printer
Built-in thermal – sensitive micro-printer, can use information, program parameters, real – time state printing.
Parameters
1. Precision glass syringe is used as sampling power
2. Adopt high precision, high pressure, high chemical stability valve body
3. Built-in mini printer
4. Multi-user management
5. Wifi, bluetooth, RS232, RS485 extension interface
6. Biometric identification technology
7. High chemical stability of the internal use of ptfe pipeline
8. Filtrate discharge function, reduce adsorption
9. With the function of equal volume replenishment
10. With independent pipeline system, which can meet the requirements of blank and standard products for dissolution test
11. A 16-bit test tube holder can hold up to 128/192 test tubes
12. The sampling tube is equipped with a silicone cap to prevent sample evaporation and contamination
13. It can run on line with the dissolver
14. Ampoule bottle collecting device
15. High sensitivity capacitive touch screen
16. Authority management
17. Audit trails
Technical indicators
Sampling channel | 8/12 |
Sampling frequency | 16 |
Maximum sampling interval | 99h59min |
Minimum sampling interval | 1 minute for the first time. The remaining 2~10 minutes (depending on the sampling amount, sampling method and whether the liquid is replenished) |
Continuous working time | 99h59min *16 |
Sampling filtration period | <30s |
Sample volume | 1ml~100ml |
Single pipe capacity | 0ml~15ml |
Sampling accuracy | RSD1%(10ml) |
Number of users | 7 |
User level | 3 |
User program | 99 |
Record keeping | 128*366days |
Intelligent Disintegrator
1. Capacitive touch screen
High sensitivity color LCD capacitive touch screen, clear color, smooth operation and detailed display. Toughened glass screen, durable, high transparency.
2. One-body water bath
Adopt the injection molding integrated PC water bath, no circulation dead Angle, high strength, high temperature resistance, easy to clean, the deficiency of PMMA in strength, temperature and life was avoided.
3. Illuminating system
With a patented lighting system of 1, it is convenient to observe the sample disintegration, and the fog surface is astigmatized to avoid stimulating the user’s vision, while illuminating the entire beaker.
4. Quickly remove and install the hanging basket card
With patent 2, it can quickly disassemble and install and adjust the height of the hanging basket card, which integrates positioning, height adjustment, fastening and a whole body. It can realize the quick reading and dismounting of the hanging basket, which is convenient and practical.
5. Full size screen
Provide 2mm, equipped with 1mm, 0.71mm, and 0.42mm sieve mesh are selected to meet different user’s requirements.
6. High precision temperature sensor
German imports of 1/3 b (highest level) and high precision Pt1000 platinum resistance temperature sensor, good linear, low temperature drift, quick response, high precision, at the same time using ptfe sheathed with temperature compensation, super soft, pure copper, silver, high temperature resistant AFR250 cable. The water bath temperature can be feedback more quickly and accurately.
7. Inside the cup correction
The temperature correction in the cup is adopted to avoid the error caused by the temperature correction in the tank of the traditional caving instrument.
Parameters
1. Three baskets disintegration time detection system
2. High precision PT1000 temperature sensor
3. Temperature correction in cup
4. The test time can be adjusted
5. Real-time display of time temperature
6. Overheating protection
7. Integral water bath box, no water bath circulation dead Angle, easy to clean
8. Overall appearance design, high – grade simplicity
9. Independent lighting system
10. Voice prompt
11. One-piece, quick removal of hanging basket card
12. High sensitivity capacitive touch screen
13. Authority management
14. Audit trails
Technical indicators
Temperature range | Indoor temperature-45℃ |
Temperature resolution | 0.01℃ |
Number of hanging basket | 3 |
Lift frequency | 30-32 times/min |
Lifting distance | 55mm±1mm |
Spacing between bottom and bottom of screen | 25mm±2mm |
Mesh size | 2mm, optional 1mm、0.71mm、0.42mm |
Block density | 1.18-1.2g/cm |
Number of users | 7 |
User level | 3 |
Record keeping | 96*366days |
Dissolution Tester
Features
1. High precision dissolution cup
All parameters of the high precision and satisfactory dissolution cup meet the requirements of the Chinese pharmacopoeia.
2. Automatic dosage
Automatic dosing can be realized, including automatic synchronous dosing and automatic sequence dosing, so as to facilitate users in different ways of use.
3. Solvent temperature monitoring
The temperature monitoring system can monitor the temperature of solvent in real time or at sampling time. Synchronously monitor the temperature of the rehydration solution and realize isothermal rehydration.
4. Influence of cover
Avoid solvent evaporation and cross contamination
5. The sampling point is automatically positioned
According to the set method and the volume of the solvent, the height of sampling point can be automatically determined with high precision and fast speed.
6. Biometric identification technology
Capacitive fingerprint recgnition system can recognize the user’s identity,avoiding the user name password login tedious,easy to use.
7. Magnetic induction water flow sensor
The water flow sensor of magnetic induction technology is adopted to monitor the water flow in the circulating pipeline, so as to ensure no dry burning and more reliable.
8. Built-in permission management system
The three-level permission management system is adopted, which is divided into guest account, ordinary account and administrator account. Different permissions are assigned to different accounts.
9. Electric lifting head
Electric lifting head, double positioning cone positioning, patented technology, adjustable head fixing structure. Make sure the cup plate is parallel to the machine head and the instrument parameters are stable and reliable.
10. Quick disassembly system for dissolving cups
Dissolve the cup holder and cup holder ring can be disassembled quickly,and can be adjusted to 360°,it’s easy and convenient to use.
11. Removable control box
The control box can be repaired without moving the host machine during maintenance, and no mechanical correction is required.
12. Normally closed temperature switch
Adopted normally closed temperature switches, power automatically cut when temperature more than 55 ℃, safe and reliable.
RC810G/RC1210G
Parameters
1. The experiments of basket method, paddle method, cup method, plate method (large and small plate ) and drum method (long and short tube) can be carried out to meet the requirements of blank and contrast.
2. Motor head electric lifting
3. Self-aligning clutch
4. Simultaneous drug and sequence
5. Dual color lighting system
6. Multi-user management
7. Wifi, bluetooth, RS232, RS485 extension interface
8. Biometric identification technology
9. Built-in printer
10. High sensitivity capacitive touch screen
11. Authority management
12. Audit trails
Technical indicators
Test unit number | 8/12+2 |
Water bath temperature | Indoor temperature-45℃ |
Temperature resolution | 0.01℃ |
Stirring speed | 25RPM-250RPM |
Stirring speed resolution | 0.01RPM |
Drug channel | 8/12 |
Machine head lifting mode | Electric |
Illuminating system | White light, red light |
Number of users | 7 |
User level | 3 |
User program | 99 |
Record keeping | 128*366days |
RC810
Parameters
1. The experiments of basket method, paddle method, cup method, plate method (large and small plate ) and drum method (long and short tube) can be carried out to meet the requirements of blank and contrast.
2. Motor head electric lifting
3. Self-aligning clutch
4. Simultaneous drug and sequence
5. Multi-user management
6. Authority management
7. Audit trails
Technical indicators
Test unit number | 8 |
Water bath temperature | Indoor temperature-45℃ |
Temperature resolution | 0.01℃ |
Stirring speed | 25RPM-250RPM |
Stirring speed resolution | 0.01RPM |
Drug channel | 8 |
Machine head lifting mode | Electric |
Number of users | 7 |
User level | 3 |
User program | 99 |
Record keeping | 128*366days |
RC801S/RC1210S
Parameters
1. The experiments of basket method, paddle method, cup method, plate method (large and small plate ) and drum method (long and short tube) can be carried out to meet the requirements of blank and contrast.
2. Motor head electric lifting
3. Electric lifting of sampling frame
4. Self-aligning clutch
5. Automatic and independent drug delivery
6. Dual color lighting system
7. Multi-user management
8. Wifi, bluetooth, RS232, RS485 extension interface
9. Biometric identification technology
10. Built-in printer
11. Solvent monitoring
12. Stirring speed monitoring
13. Multi-user management
14. Connect with the prototype
15. High sensitivity capacitive touch screen
16. Authority management
17. Audit trails
Technical indicators
Test unit number | 8/12+2 |
Water bath temperature | Indoor temperature-45℃ |
Solvent temperature monitoring | 8/14 channel |
Temperature resolution | 0.01℃ |
Stirring speed | 25RPM-250RPM |
Stirring speed resolution | 0.01RPM |
Drug channel | 8/12 |
Machine head lifting mode | Electric |
Lifting mode of sampling frame | Electric、automatic |
Sample point resolution | 1ml |
Illuminating system | White light, red light |
Number of users | 7 |
User level | 3 |
User program | 99 |
Record keeping | 128*366days |