Upon request each system can be supplied as manual configuration.
High pressure side prime and purge valves in eluent and reagent flow.
Based on chemical process regeneration of suppressors with acid.
Manual and automatic peak integration with integrated IQ/OQ procedure for software (only available with software Clarity).
The IONUS can be equipped with an additional UV/VIS detector.
Programmable thermostat for column (and suppressors).
method | ion exchange chromatography of anions and cations in subsequent mode |
manual injection | 20 µL, further injection loops upon request (50 µL, 100 µL, 200 µL) |
autosampler | 2 racks, each of them with space for 48 vials (1.5 mL) or 12 vials (6 mL), sample cooling, loop 100 µL, 3 injection modes (full-loop, partial loop, microliter-pickup) |
column | stainless steel / PEEK |
temperature stability / range | ~ 0.5 °C / ambient up to 50 °C |
detection | conductivity detector: noise: 0.02 µS, 1s | linearity: < 1 s | range: 0 – 10 mS/cm effective cell volume: 1 µL, conductivity block: 30 °C |
isocratic pump system | max. pressure: 400 bar | flow rate: 0.01 – 10.00 mL/min reproducibility of flow rate: 0.1 % RSD at 100 µL/min |
maximum operating pressure | 120 bar |
control software & data aquisition | Clarity (21 CFR part 11 compliant) or AminoPeak |
dimensions, weight, power | 1000 x 350 x 375 mm*, 60 kg, 110 – 230 V, 50/60 Hz |
*800 mm with opened main unit |
---|
Depending on the application the IONUS PCD is equipped with one Photometer. Further equipment can be requested on demand. 440 nm: Bromate according to EPA 317 or organic acids; 355 nm: Bromate according to EPA326, 530 nm: Transition metals.
High pressure side prime and purge valves in eluent and reagent flow.
Manual and automatic peak integration with integrated IQ/OQ procedure for software (only available with software Clarity).
The IONUS can be equipped with an additional UV/VIS detector.
method | ion exchange chromatography with post column derivatization |
manual injection | 20 µL, further injection loops upon request (50 µL, 100 µL, 200 µL) |
autosampler | 2 racks, each of them with space for 48 vials (1.5 mL) or 12 vials (6 mL), sample cooling, loop 100 µL, 3 injection modes (full-loop, partial loop, microliter-pickup) |
column | stainless steel / PEEK |
temperature stability / range | ~ 0.5 °C / ambient up to 50 °C |
detection | post column derivatization (PCD) with a singe wavelength photometer in UV-VIS range (440 nm, 355 nm, 530 nm) depending on application |
isocratic pump system | max. pressure: 400 bar | flow rate: 0.01 – 10.00 mL/min reproducibility of flow rate: 0.1 % RSD at 100 µL/min |
maximum operating pressure | 120 bar |
control software & data aquisition | Clarity (21 CFR part 11 compliant) or AminoPeak |
dimensions, weight, power | 1000 x 350 x 375 mm*, 60 kg, 110 – 230 V, 50/60 Hz |
*800 mm with opened main unit |
---|