The ARAUS lite can be upgraded later on with autosampler.
High pressure side prime and purge valves in eluent and reagent flow.
Validation documents IQ/OQ and PQ for ARACUS.
Manual and automatic peak integration with integrated IQ/OQ procedure for software (only available with software Clarity).
It supplies the main unit and eluent box with a protective gas atmosphere by reducing the presence of atmospheric oxygen to enhance the signal to noise ratio.
The existing 500 or 570 nm photometer will be replaced by a photometer with 440 nm and 570 nm wavelength.
method | post column derivatization with Ninhydrin |
autosampler | ARACUS lite can be upgraded with autosampler; 2 racks, each of them with space for 48 vials, sample cooling dosage in 3 different injection modes: full loop (100 μL), partial loop (5 – 50 μL), microliter pickup (1 – 35 μL) |
column | stainless steel, cation exchange resin reproducibility of retention time < 0.3 % RSD, reproducibility of peak area ~ 1.0 % RSD |
column oven | 20 – 100 °C, accuracy 0.1 % |
reactor temperature | 20 – 140 °C |
spectroscopic detection | measuring range: high, low LED photometer (570 nm or 500 nm), or dual photometer (440 # 570 nm), 8 years warranty, flow cell: 10 μL volume, 3 years warranty |
detection limit | < 40 pmol / 20 µL with Ninhydrin |
quantification limit | > 100 pmol / 20 µL with Ninhydrin |
pump system | single pump reproducibility of low rate: 0.1 % RSD at 100 μL/min, max. pressure: 400 bar | flow rate: 0.01 – 10.00 mL/min |
maximum operating pressure | 120 bar |
ready to use kits | kits including eluents, reagent and additional dilution buffer, ammonia adsorber and separation columns for 500 – 1000 runs |
columns & eluents | Compatible with all High-Speed and High-Resolution columns, operating with all eluents based on different ionic strength (Li, Na, K) |
control software & data aquisition | Clarity (21 CFR part 11 compliant) or AminoPeak |
dimensions, weight, power | 1080 x 370 x 375 mm*, 60 kg, 110 – 230 V |
*800 mm with opened main unit |
---|
Upon request each system can be supplied as manual configuration.
High pressure side prime and purge valves in eluent and reagent flow.
Validation documents IQ/OQ and PQ for ARACUS.
Manual and automatic peak integration with integrated IQ/OQ procedure for software (only available with software Clarity).
It supplies the main unit and eluent box with a protective gas atmosphere by reducing the presence of atmospheric oxygen to enhance the signal to noise ratio.
Active control of fluid volume by weight cell of each bottle. (only available with software aminoPeak).
IVD kit for the qualitative and quantitative determination of amino acids in physiological fluids like human blood and urine for medical diagnostics in combination with the ARACUS IVD classic.
method | post column derivatization with Ninhydrin |
autosampler | 2 racks, each of them with space for 48 vials, sample cooling dosage in 3 different injection modes: full loop (100 μL), partial loop (5 – 50 μL), microliter pickup (1 – 35 μL) |
column | stainless steel, cation exchange resin reproducibility of retention time < 0.3 % RSD, reproducibility of peak area ~ 1.0 % RSD |
column oven | 20 – 100 °C, accuracy 0.1 % |
reactor temperature | 20 – 140 °C |
spectroscopic detection | measuring range: high, low LED photometers (440 nm + 570 nm), 8 years warranty, flow cell: 10 μL volume, 3 years warranty |
detection limit | < 40 pmol / 20 µL with Ninhydrin |
quantification limit | > 100 pmol / 20 µL with Ninhydrin |
pump system | single pump, reproducibility of low rate: 0.1 % RSD at 100 μL/min, max. pressure: 400 bar | flow rate: 0.01 – 10.00 mL/min |
maximum operating pressure | 120 bar |
ready to use kits | kits including eluents, reagent and additional dilution buffer, ammonia adsorber and separation columns for 500 – 1000 runs |
columns & eluents | Compatible with all columns, operating with all eluents based on different ionic strength (Li, Na, K) |
control software & data aquisition | Clarity (21 CFR part 11 compliant) or AminoPeak |
dimensions, weight, power | 1080 x 370 x 375 mm*, 60 kg, 110 – 230 V |
*800 mm with opened main unit |
---|
Upon request each system can be supplied as manual configuration.
High pressure side prime and purge valves in eluent and reagent flow.
Validation documents IQ/OQ and PQ for ARACUS.
For sensitive fluorescence detection of 1° amines with o-phatalaldehyde (OPA) we are providing the suitable fluorescence detector.
It supplies the main unit and eluent box with a protective gas atmosphere by reducing the presence of atmospheric oxygen to enhance the signal to noise ratio.
Active control of fluid volume by weight cell of each bottle. (only available with software aminoPeak).
IVD kit for the qualitative and quantitative determination of amino acids in physiological fluids like human blood and urine for medical diagnostics in combination with the ARACUS IVD advanced.
Manual and automatic peak integration with integrated IQ/OQ procedure for software (only available with software Clarity).
method | post column derivatization with Ninhydrin or OPA |
autosampler | 2 racks, each of them with space for 48 vials, sample cooling dosage in 3 different injection modes: full loop (100 μL), partial loop (5 – 50 μL), microliter pickup (1 – 35 μL) |
column | stainless steel, cation exchange resin reproducibility of retention time < 1 % RSD, reproducibility of peak area < 3.0 % RSD |
column oven | 20 – 100 °C, accuracy 0.1 % |
reactor temperature | 20 – 140 °C |
spectroscopic detection | measuring range: high, low LED photometers (440 nm + 570 nm), 8 years warranty, flow cell: 10 μL volume, 3 years warranty |
detection limit | < 40 pmol / 20 µL with Ninhydrin, < 4 pmol / 20 µL with OPA |
quantification limit | > 100 pmol / 20 µL with Ninhydrin, > 10 pmol / 20 µL with OPA |
pump system | dual pump reproducibility of low rate: 0.1 % RSD at 100 μL/min, max. pressure: 400 bar | flow rate: 0.01 – 10.00 mL/min |
maximum operating pressure | 120 bar |
ready to use kits | kits including eluents, reagent and additional dilution buffer, ammonia adsorber and separation columns for 500 – 1000 runs |
columns & eluents | Compatible with all columns, operating with all eluents based on different ionic strength (Li, Na, K) |
control software & data aquisition | Clarity (21 CFR part 11 compliant) or AminoPeak |
dimensions, weight, power | 1000 x 680 x 360 mm*, 60 kg, 110 – 230 V |
*800 mm with opened main unit |
---|