Symmetric M1 is a quantitative lateral flow test for the determination of Aflatoxin M1 in cow, sheep, goat, UHT and lyophilized milk. It is developed and manufactured to safely test EU limits (0.05μg/kg).
■ Kit available in 48 and 96 tests
■ Strip test format
■ Quantification Range: 8-150 ppt
■ LOD: 6 ppt
■ LOQ: 8 ppt
■ Highly accurate results: CV< 8% (30-75 ppt of AFM1)
■ Total test time including incubation: 10 minutes
■ Shelf Life: 12 months | Storage 2-8 °C
■ Common reader for all lateral flow tests
■ S-Flow software
Symmetric Total Green 0–30 is a lateral flow test for the quantitative detection of Total Aflatoxin in grains, nuts, and cereals. It uses a water-based extraction method instead of traditional organic solvents and comes in a convenient strip format.
■ Kit available in 24 and 48 tests
■ Strip test format
■ LOD: 0,9ppb (Type I & II), 1,7ppb (Type III & IV)
■ LOQ: 1,3ppb (Type I & II), 2,5ppb (Type III & IV)
■ Quantification Range: 1,3 – 30ppb Type I & II, 2,5-50ppb Type III & IV
■ Extended quantification range through sample dilution
■ Cross-reactivity: The cross-reaction of the anti-Aflatoxin antibody with Aflatoxin B1, B2, G1 and G2 is 100, 81, 73 and 55% respectively
■ Test time: 3 minutes
■ Shelf Life: 12 months
■ Storage: 2-8 °C
■ Common reader for all lateral flow tests
■ Reagents provided: sample diluent tubes, extraction solution, high range solution
■ Reader: 3PR mini,S-Flow
■ Software: S-Flow
Symmetric DON Green is a lateral flow test for the quantitative detection of Deoxynivalenol (DON) in grains, cereals, and animal feed. It uses water-based extraction instead of traditional organic solvents and comes in a convenient strip format.
■ Kit available in 24 and 48 tests
■ Strip test format
■ LOD: 0.1 ppm
■ LOQ: 0.15 ppm
■ Quantification Range: 0.15-5 ppm
■ Extended quantification range through sample dilution
■ Cross-reactivity: The cross-reaction of the anti-DON antibody with 15-acetyl-DON, DON and 3-acetyl-DON is >100, 100, <0.1% respectively
■ Test time: 3 minutes
■ Shelf Life: 12 months
■ Storage: 2-8 °C
■ Common reader for all lateral flow tests
■ Reagents provided: sample diluent tubes, extraction solution, high range solution
■ Reader: 3PR mini
■ Software: S-Flow
Symmetric M1 1000 is a quantitative lateral flow test for the determination of Aflatoxin M1 in raw and pasteurized cow and UHT milk. It is developed and manufactured to safely test US and Asian legislation limits.
■ Kit available in 48 and 96 tests
■ Strip test format
■ Quantification Range: 70-1000 ppt
■ LOD: 47 ppt
■ LOQ: 70 ppt
■ Highly accurate results: CV< 8% (250-700 ppt of AFM1)
■ Total test time including incubation: 3 minutes
■ Shelf Life: 12 months
■ Storage 2-8 °C
■ Common reader for all lateral flow tests
■ S-Flow software
Symmetric Ochratoxin Green is a lateral flow test for the quantitative detection of Ochratoxin A (OTA) in grains, cereals, and nuts. It uses water-based extraction instead of traditional organic solvents and comes in a convenient strip format.
■ Kit available in 24 and 48 tests
■ Strip test format
■ LOD: 0,7ppb (Type I & II), 1,7ppb (Type III & IV)
■ LOQ: 1ppb (Type I & II), 2,5ppb (Type III & IV)
■ Quantification Range: 1 – 20ppb (Type I & II), 2,5-50ppb (Type III & IV)
■ Extended quantification range through sample dilution
■ Cross-reactivity: The cross-reaction of the anti-Ochratoxin antibody with Ochratoxin A and B is 100 and <0.1% respectively
■ Test time: 3 minutes
■ Shelf Life: 12 months
■ Common reader for all lateral flow tests
■ Reagents provided: sample diluent tubes, extraction solution, high range solution
■ Reader: 3PR mini
■ Software: S-Flow
■ Competitive Quantitative ELISA test with single-break strip plate with 48 wells (6 strips) or 96 wells (12 strips)
■ Limit of detection (LOD): 2 ppm of Histamine
■ Wide range of quantification: 2.5-200 ppm of Histamine
■ Low Procedure time: 20 mins
■ No acylation process needed
■ High specificity and sensitivity
■ All reagents are in ready to use format
■ Adjusted to the global legislation limits for Histamine
■ Shelf Life: 12 months | Storage 2-8 °C
■ Lateral flow in cassette format available in 1, 2, 5, 20 or 40 tests
■ Clinical Evaluation Study with 370 specimens (prior confirmed with RT-PCR assay) showed: 96.33% sensitivity & 99.62% specificity
■ Clinical performance with 528 nasal specimens (prior confirmed with RT-PCR assay) showed: 98.59% sensitivity & 99.74% specificity
■ The test provides the option for nasal swab sampling for less patient discomfort
■ Visual interpretation of the results in 15 mins
■ Simple method, no need for special equipment
■ Rapid Test Ag 2019-nCov is confirmed to detect variants B.1.1.7 (Alpha), B.1.351 (Beta), B.1.429, B.1.427, B.1.2 , P1 (Gamma), P2, B.1.617.2 (Delta), B.1.617.3, C.37 (Lambda), P.3 (Theta), B.1.617.1 (Kappa), B.1.525 (Eta), B.1.526.1 B.1.526.2 (Iota) and the new variant B.1.1.529 (Omicron)
■ Shelf Life: 24 months | Storage 4-30 oC
The test has received the CE-IVD
■ Test should only be conducted by medical personnel
Rapid Test 2019-nCoV Total Immunoglobulins
Rapid test 2019-nCoV Total is a qualitative Lateral Flow test for the determination of IgA, IgM and IgG antibodies against SARS-CoV-2 in human serum, plasma or whole blood specimens.
■ Lateral flow in dip stick format available in 10 or 30 test sticks
■ Clinical Diagnostic Sensitivity 98,75%, 79/80 (CI: 0.9325 to 0.9978), Clinical Diagnostic Specificity 100%, 114/114 (CI: 0.9674 to 1)
■ Ιnternal validation results: 94.87%, 74/78 (CI: 0.8754 to 0.9799) sensitivity & 100%, 335/335 (CI: 0.9887 to 1). specificity
■ Low procedure time: 10 min
■ Easy-to-use method, no need for equipment or special facilities
■ Visual interpretation of the results
■ Shelf Life: 12 months | Storage 4-30°C
■ The test has received the CE-IVD mark
Symmetric Histamine is an innovative Lateral Flow test for the quantitative determination of Histamine in fresh fish, canned fish, frozen fish, and fish meal. The method is the only fully quantitative rapid test for Histamine, and it does not require an acylation process.
Optional visual detection limit at 35 ppm
■ Lateral flow in dip stick format available in 30 test sticks
■ Limit of detection (LOD): 5.3 ppm
■ Range of quantification: 8-300 ppm
■ Low procedure time (3 min)
■ No acylation process needed
■ Highly accurate results
■ Adjusted to the global legislation limits for Histamine
■ Shelf Life: 12 months | Storage 15-25 °C
Symmetric B1 Green is a lateral flow test for the quantitative detection of Aflatoxin B1 (AFB1) in grains, cereals, and nuts. It uses water-based extraction instead of traditional organic solvents and comes in a convenient strip format.
■ Kit available in 24 and 48 tests
■ Strip test format
■ LOD: 0,9ppb (Type I & II), 1,7ppb (Type III & IV)
■ LOQ: 1,3ppb (Type I & II), 2,5ppb (Type III & IV)
■ Quantification Range: 1,3 – 30ppb Type I & II, 2,5-50ppb Type III & IV
■ Extended quantification range through sample dilution
■ Cross-reactivity: The cross-reaction of the anti-Aflatoxin antibody with Aflatoxin B1, B2, G1 and G2 is 100, 50, 44 and 15% respectively
■ Test time: 3 minutes
■ Shelf Life: 12 months
■ Storage: 2-8 °C
■ Common reader for all lateral flow tests
■ Reagents provided: sample diluent tubes, extraction solution, high range solution
■ Reader: 3PR mini
■ Software: S-Flow
Symmetric B1 ES is an innovative Lateral Flow test that utilizes state-of-the-art features for the quantitative determination of Aflatoxin B1 (AFB1) in grains, cereals, nuts and animal feed. This rapid test in strip format uses an organic solvent for the extraction step, making it ideal for complex matrices.
■ Kit available in 24 and 48 tests
■ Strip test format
■ LOD: 0.5ppb (Type I), 0.6ppb (Type II)
■ LOQ: 0.7ppb (Type I), 1ppb (Type II)
■ Quantification Range: 0.7- 20 ppb (Type I), 1-20 ppb (Type II)
■ Extended quantification range through sample dilution
■ Reagents provided: diluent tubes, high range solution
■ Cross-reactivity: The cross-reaction of the anti-Aflatoxin antibody with Aflatoxin B1, B2, G1 and G2 is 100, 43, 47 and 8% respectively.
■ Test time: 10 minutes
■ Shelf Life: 12 months
■ Storage: 2-8 °C
■ Common reader for all lateral flow tests
■ Reader: 3PR mini
■ Software: S-Flow
Symmetric Total ES is an innovative Lateral Flow test that utilizes state-of-the-art features for the quantitative determination of Total Aflatoxin in grains, cereals, nuts and animal feeds. This rapid test in strip format uses an organic solvent for the extraction step, making it ideal for complex matrices.
■ Kit available in 24 and 48 tests
■ Strip test format
■ LOD: 0.2ppb (Type I), 0.3ppb (Type II)
■ LOQ: 0.35ppb (Type I), 0.5ppb (Type II)
■ Quantification Range: 0.35 – 10 ppb (Type I), 0.5-10 ppb (Type II)
■ Extended quantification range through sample dilution
■ Reagents provided: diluent tubes, high range solution
■ Cross-reactivity: The cross-reaction of the anti-Aflatoxin antibody with Aflatoxin B1, B2, G1 and G2 is 100, 79, 89 and 45% respectively.
■ Test time: 10 minutes
■ Shelf Life: 12 months
■ Storage: 2-8 °C
■ Common reader for all lateral flow tests
■ Reader: 3PR mini
■ Software: S-Flow
Symmetric ZON Green is a lateral flow test for the quantitative detection of Zearalenone (ZON) in grains and cereals. It uses a water-based extraction method instead of traditional organic solvents and comes in a convenient strip format.
■ Kit available in 24 and 48 tests
■ Strip test format
■ LOD: 24ppb ZON
■ LOQ: 35ppb ZON
■ Quantification Range: 35-800 ppb
■ Extended quantification range through sample dilution
■ Cross-reactivity: The cross-reaction of the anti-ZON antibody with Zearalenone, α-zearalenol, β-zearalenol, Zearalanone, α-zearalanol and β-zearalanol is 100, 85, 47, 96, 80 and 82% respectively.
■ Test time: 3 minutes
■ Shelf Life: 12 months
■ Storage: 2-8 °C
■ Common reader for all lateral flow tests
■ Reagents provided: sample diluent tubes, extraction solution, high range solution
■ Reader: 3PR mini
■ Software: S-Flow
Symmetric OCHRATOXIN Wine is a lateral flow test for the quantitative detection of Ochratoxin A (OTA) in wine, must, and grape juice. It provides visual results for samples above 2 ppb of OTA—no reader required—and comes in a convenient strip format.
■ Kit available in 24 and 48 tests
■ Strip test format
■ LOD: 0.2 ppb OTA
■ LOQ: 0.35 ppb OTA
■ Quantification Range: 0.35 – 5ppb
■ Cross-reactivity: The cross-reaction of the anti-Ochratoxin antibody with Ochratoxin A and B is 100 and <0.1% respectively.
■ Sample diluent tubes provided
■ Test time: 5 minutes
■ Shelf Life: 12 months
■ Storage: 2-8 °C
■ Common reader for all lateral flow tests
■ Reader: 3PR mini
■ Software: S-Flow
Symmetric Fumonisin Green is a lateral flow test for the quantitative detection of Fumonisin (FUMO) in grains, cereals, and animal feed. It uses water-based extraction instead of traditional organic solvents and comes in a convenient strip format.
■ Kit available in 24 and 48 tests
■ Strip test format
■ LOD: 0.1 ppm Fumonisin
■ LOQ: 0.15 ppm Fumonisin
■ Quantification Range: 0.15 – 4 ppm
■ Extended quantification range through sample dilution
■ Cross-reactivity: The cross-reaction of the anti-Fumonisin antibody with FB1, FB2 and FB3 is 100, 65 and 48% respectively
■ Test time: 3 minutes
■ Shelf Life: 12 months
■ Storage: 2-8 °C
■ Common reader for all lateral flow tests
■ Reagents provided: sample diluent tubes, extraction solution, high range solution
■ Reader: 3PR mini
■ Software: S-Flow
Symmetric T-2/HT-2 Green is a lateral flow test for the quantitative detection of T-2/HT-2 toxins in grains and cereals. It uses water-based extraction instead of traditional organic solvents and comes in a convenient strip format
■ Kit available in 24 and 48 tests
■ Strip test format
■ LOD: 16.5ppb (Type I), 10ppb (Type II) & 34ppb (Type III)
■ LOQ: 25ppb (Type I), 15ppb (Type II) & 50ppb (Type III)
■ Quantification Range: 25-300ppb (Type I), 15-200ppb (Type II), 50-1000ppb (Type III)
■ Extended quantification range through sample dilution
■ Cross-reactivity: The cross-reaction of the anti-T-2 antibody with HT-2, T-2 Triol and T-2 Tetraol is 80, 3.7 and <0.1% respectively.
■ Test time: 3 minutes
■ Shelf Life: 12 months
■ Storage: 2-8 °C
■ Common reader for all lateral flow tests
■ Reagents provided: sample diluent tubes, extraction solution, high range solution
■ Reader: 3PR mini
■ Software: S-Flow